While we’re happy to “talk tech” with you all day long, we know you’re in a hurry.
So we’ve made it easy for you to download product manuals, datasheets and downloadable software which includes firmware, drivers, etc. for all our current products, and many discontinued products as well. Just tell us which product you’re using, and we’ll provide you with list of latest documents and resources that you can download.
The product model you have chosen is currently available for purchase. The following support information is available.
-
Datasheet Literature Number: ReleaseDate KickStart Instrument Control Software Datasheet
KickStart Software simplifies what you need to know about your instrument so that in just minutes you can take the instrument out of the box and get real data on your device. KickStart Software enables quick test setup and data visualization when …1KW-60965-13
-
Manuals Manual Type Part Number: ReleaseDate MDO4000C, MDO4000B, MDO4000, MSO4000B, DPO4000B, and MDO3000 Series Programmer Manual
Digital oscilloscopes programming commandsProgrammer Manuals 077051009 Tektronix Demo 3 Board Instruction Manual
Demo 3 Board Instruction ManualTraining/Tutorials 071286202 MSO4000B and DPO4000B Series Specifications and Performance Verification Manual
Digital Phosphor OscilloscopesSpecifications and Performance VerificationPerformance Verification 077050903 MSO4000B and DPO4000B Series User Manual
Digital Phosphor OscilloscopesPrimary User 071281004 RMD5000
Tektronix DPO & MSO 4000B Series and DPO & MSO5000/B Series Rackmount Kit InstructionsField Install Instructions 075102002 MSO4000B and DPO4000B Series and Application Modules Declassification and Security Instructions
Declassification and SecurityDeclassification Manuals 077051101 MSO4000B and DPO4000B Series Service Manual
Digital Phosphor OscilloscopesService Manuals 077051202 Read This First
Download the Latest IVI Drivers Read This FirstRelease Notes 061438100 HCTEK54 Transit Case Instructions
Transit CaseUser Manuals 071282800 MDO4000, MSO4000, MSO4000B, DPO4000, DPO4000B Series Application Module Installation Instructions
Application ModuleUser Manuals 071213601 Probe and Accessories Pouch Installation Instructions
Pouch InstallationField Install Instructions 071283000
-
Technical Documents Document Type ReleaseDate When to Choose a Dedicated Arbitrary Function Generator (AFG)
This technical brief is written to help you determine the optimum method of arbitrary function generation for your needs. It shows examples of real-world applications and highlights key specifications of Tektronix and Keithley dedicated arbitrary …Technical Brief Serial Support Using Tektronix Oscilloscopes and Optional Software
Tektronix oscilloscopes offer a portfolio of optional analysis capabilities to simplify serial bus debug or compliance verification. This selection matrix shows which serial standards are supported by each of the oscilloscope series.Product Selector Guide Measuring Power Supply Switching Loss with an Oscilloscope
Introduction With the demand for improving power efficiency and extending the operating time of battery-powered devices, the ability to analyze power loss and optimize power supply efficiency is more critical than ever …Application Note Probing Techniques for Accurate Voltage Measurements on Power Supplies with Oscilloscopes
This application note describes considerations and techniques for making accurate voltage measurements on power converters with an oscilloscope, especially as they relate to probe selection and application. It includes two examples for …Application Note How to Minimize Probe Loading with Low Capacitance Probes
Probing a circuit always has some impact on signals. Probe loading changes the signal being probed and can cause measurement problems or can even cause a circuit to perform differently. Reducing capacitive loading can help minimize these effects. In …Application Note Debugging Serial Buses in Embedded System Designs
Introduction Embedded systems are literally everywhere in our society today. A simple definition of an embedded system is a specialpurpose computer system that is part of a larger system or machine with the intended purpose of …Application Note How to Use a Mixed Signal Oscilloscope to Test Digital Circuits
The ability to present both analog and digital representations of signals make mixed signal oscilloscopes (MSOs) ideal for verifying and debugging digital circuits. This application note provides tips to help you efficiently debug …Application Note Wave Inspector® Navigation and Search: Simplifying Waveform Analysis
Modern digital oscilloscopes can capture massive amounts of data which must then be analyzed. Discover how the Tektronix Wave Inspector® navigation and search capability gives you the tools to extract the answers you need fast and efficiently.Application Note Making Accurate Current Measurements on Power Supplies with Oscilloscopes
This application note describes considerations and techniques for making accurate current measurements on power converters using an oscilloscope and a current probe. When used in conjunction with an oscilloscope’s voltage measurements …Application Note Smiths Detection Relies on Tektronix to Take the Trouble out of Troubleshooting
A team of engineers at Smith Detection needed to quickly, efficiently and accurately identify and resolve problems during the development of complex handheld devices. Learn how Smith Detection engineers used Tektronix bench instruments to identify a …Technical Brief iCub Robot Gets Battery Power with Help of Tektronix Oscilloscope, Voltage and Current Probes
Customer Solution Summary CHALLENGE Developers at the Istituto Italiano Di Tecnologia (IIT) needed to validate and troubleshoot a new battery backpack power supply system for the iCub robot, an open-source cognitive humanoid robot …Case Study Power Supply Measurement and Analysis Primer
A power supply is a component, subsystem, or system that converts electrical power from one form to another; commonly from alternating current (AC) utility power to direct current (DC) power. The proper operation of electronic devices ranging from …Primer Power Supply Measurement & Analysis with Bench Oscilloscopes
Introduction Power supplies can be found in many different electronic devices, from children’s toys to computers and office equipment to industrial equipment. They are used to convert electrical power from one form to another for …Application Note Introduction to Video Measurements
In this application note, we demonstrate using a MSO/DPO5000, MDO/MSO/DPO4000 and MDO/MSO/DPO3000 Series Oscilloscope to make a variety of video measurements that are common in standard and high definition systems.Application Note Testing a New Switch Mode Power Supply Design Poster
Get a quick overview of the key measurements for verifying a new switch mode power supply (SMPS) design. This poster shows key measurements, from verifying your prototype during initial startup, to optimizing switching loss and magnetic losses, to …Poster Tektronix MSO/DPO4000 Series vs. LeCroy WaveSurfer XS Fact Sheet
Serial Triggering and Decode Tektronix MSO/DPO3000 Series ✔ Simple time-correlated and labeled bus form display with color coded decode ✔ Wave Inspector® controls quickly navigate through long …Competitive MDO4000B Series vs. Agilent/Keysight MSOX4000A Series
When comparing oscilloscopes, check the details of the operation and look for “hidden” costs that prevent you from getting the versatility in performance you need to complete the wide-variety of fundamental measurement challenges you have today and …Competitive MSO/DPO4000B Series vs. Agilent MSO/DSO3000 X-Series
Side-by-side comparison on important features like serial triggering and decode, measurements and waveform math, digital debug with MSO, and more.Competitive Making MicroVolt Biomedical Measurements
Introduction Measuring electrical phenomena presents a number of unique challenges to biomedical signal measurement systems. The tiny, microVolt-level electrical pulses that signal a firing neuron or a muscle response are …Technical Brief 3000 X-Series vs. MSO/DPO4000B Series True Cost of Your Scope
Tektronix bench oscilloscopes are packed with innovative features to help you get your job done faster, built right into the scope. And, with a comprehensive set of probes and accessories included standard, you can start testing right out of the box …Competitive MSO/DPO4000 vs. Agilent MSO7000B Fact Sheet
Side-by-side comparison on important features like serial triggering and decode, waveform navigation and search, waveform capture rate, digital debug with MSO, and more.Competitive Tektronix MSO/DPO4000 Series vs. Agilent 5000A+ 6000A+ and 7000A Fact Sheet
Side-by-side comparison on important features like serial triggering and decode, waveform navigation and search, and record length.Competitive Tektronix MSO/DPO4000 Series vs. LeCroy WaveRunner Xi Fact Sheet
Side-by-side comparison on important features like serial triggering and decode, waveform navigation and search, and waveform capture rate.Competitive MSO/DPO4000 Series vs. Yokogawa DLM2000 Series
Side-by-side comparison on important features like serial triggering and decode, waveform navigation and search, user-experience, digital debug with a MSO and more.Competitive Tektronix MSO4000 Series vs. LeCroy MS-500 Mixed Signal Solution Fact Sheet
Side-by-side comparison on important features like display size, searching on analog and digital data, and setup and hold triggering.Competitive 10 Reasons Why You Have Never Seen a Mixed Signal Oscilloscope Like This
Learn more about all the innovative user-friendly features on the MSO4000 Series that have been designed to make your work easier.Brochure Oscilloscope Combines Logic Analyzer With Ease Of Use For Better Debugging
Product Article Tektronix MSOs Set Performance Benchmarks
Product Article Test methodologies for high-speed serial designs
Product Article Tektronix MSO4000 Mixed Signal Oscilloscopes Win 2008 EDN China Innovation Award
Award REVIEW: Cost-effective scopes time-correlate analog+ digital signals
Product Article Portable Scopes Designed for Embedded Design and Debug
Product Article Tek oscilloscopes catch analog and digital signals
Product Article
-
Software Document Type Part Number: ReleaseDate KickStart Instrument Control Software version 2.11.2
KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of readings. • Set up a multi-instrument test with the ability to …Application KICKSTART-2.11.2 TEKVISA Connectivity Software - V5.11.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093813 KickStart Instrument Control Software version 2.11.1
KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of readings. • Set up a multi-instrument test with the ability to …Application KICKSTART-2.11.1 Tektronix Openchoice Desktop Application TDSPCS1 - V2.8
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …Utility 066093915 TEKVISA Connectivity Software - V4.2.0
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093812 DPO2000, MSO2000, DPO3000 and DPO4000, MSO3000 and MSO4000, MDO3000 and MDO4000 and MDO3 IVI Driver - V1.5
The Tektronix MSO/DPO2000, MDO/MSO/DPO3000, MDO/MSO/DPO4000 and MDO3 IVI Driver is an IVI class-compliant driver. It complies with Scope Class specifications (IVI-4.1) as defined by the IVI foundation. An IVI class-compliant specific driver for an …Driver 066133104 MSO4000B, DPO4000B Firmware - V3.22
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447007 TEKVISA CONNECTIVITY SOFTWARE - V4.1.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093811 Tektronix Openchoice Desktop Application TDSPCS1 - v2.6
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …Utility 066093914 MSO4000B, DPO4000B Firmware, V3.20
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447006 MSO4000B, DPO4000B Firmware, V3.18
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447005 Tektronix Toolbars for Microsoft Office 32 bit - V4.0.4
Tektronix Toolbars for Microsoft Office v4.0.4 provide toolbars (add-ins) for the 32 bit versions of Microsoft Excel and Microsoft Word. This version of Toolbars requires OpenChoice TekVISA v4.0.4 (Part Number 066093809) to be preinstalled on the PC …Utility 066133202 MSO4000B, DPO4000B Firmware, V3.16
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447004 TEKVISA CONNECTIVITY SOFTWARE, V4.0.4
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol. When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093809 MSO4000B, DPO4000B FIRMWARE, V2.96
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447002 MSO4000B, DPO4000B FIRMWARE, V2.90
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447001 DPO2000, DPO3000, DPO4000 IVI Driver
The Tektronix DPO2000, DPO3000, DPO4000 IVI Driver is an IVI class-compliant driver. It complies with Scope Class specifications (IVI-4.1) as defined by the IVI foundation. An IVI class-compliant specific driver for an oscilloscope exports the API …Driver 066133101 DPO4000B AND MSO4000B FIRMWARE V2.52
This firmware is an upgrade for all DPO4000B and MSO4000B Series oscilloscopes.Firmware 063432911 DPO4000 AND MSO4000 FIRMWARE V2.62
This firmware is an upgrade for all DPO4000 and MSO4000 Series oscilloscopes.Firmware 063397016 USING MATLAB WITH MSO_DPO4000 AND MSO_DPO3000 SERIES OSCILLOSCOPES v1.0
MATLAB is a software environment and programming language that enables Tektronix oscilloscope users to acquire and analyze data, graphically visualize data, make custom measurements, generate reports, and develop automated applications. Perform …Driver 066110000
-
FAQS FAQ ID What feature does the DPO4BND included?
DPO4BND includes the features for the following modules …72101 What are some of the benefits of the TekVPI probe interface?
The biggest benefits of the TekVPI™ probe interface are versatility and ease of use. Oscilloscopes with TekVPI interface support a wide range of probes including TekVPI probes, BNC and TekProbe-BNC Level 1 probes, and TekProbe-BNC Level 2 probes …56016 When should I run SPC?
Signal Path Compensation (SPC) can be run at any time. The best times to run SPC are: After the oscilloscope has been powered on and has warmed up for 20 minutes or more. If the temperature has changed more than 5 degrees C since the last SPC was …60156 When should I use MagniVu on my oscilloscope?
MagniVu allows you to have higher resolution to accurately determine edge placement on your digital data. It helps you to make precise timing measurements on digital edges. On the MSO/MDO4000/B/C and MSO5000/B Series, you can see up to 32 times more …63886 What cart does my scope use?
Below are the Instrument Carts that can be purchased from Tektronix. K4000 K420 K475 More information can …64561 Is there a mictor adapter for the P6616 (logic probe for MSO5000B, MSO4000B, and MDO4000C + MDO4MSO) or P6516 (logic probe for the MSO4000 Series) or the P6316 (logic probe for MSO2000, MSO3000, MDO3000 + MDO3MSO Series)?
A mictor adapter is available from our partner Nexus Technologies. Use the mictor adapter NEX-HD2HEADER http://www.nexustechnology.com/products/laAccessories/hd2header/59716 Why does the Tkdpo2k3k4k_ReadWaveform() function in the Tkdpo2k3k4k IVI-C driver time out every time I call it when I am connected to the instrument via Ethernet? The function call works fine over USB, but over Ethernet it always times out.
The Tkdpo2k3k4k_ReadWaveform() function makes use of the Service Request Event in VISA so the scope can notify the driver when it has completed its acquisition and the waveform data is ready to be fetched as opposed to the driver polling the scope …72221 I cannot see my signal on the Oscilloscope. What can I do?
You have many options to help diagnose this issue, below are a few suggestions to get started. If you find yourself needing more help, please connect with our Technical Support Center. You can get started by pressing the "Contact Us" button on the …63686 I could not find any information regarding the increase in bits in resolution for HiRes mode. Is there any information available?
The increase in bits in resolution depends on the decimation ratio. The decimation ratio can be determined as follows:D = MFs / FsMFs is the maximum non-interleaved sampling frequency of the scope. For example: 5 GS/s for the DPO4104B or 2.5 GS/s …55421 I saved some oscilloscope .wfm and .isf files+ how do I view them on my pc?
The .isf and .wfm is the internal file format. It is designed first and foremost to be easily used by the oscilloscope. Most .wfm files (as well as many other waveform file formats) can be opened with TekScope. You can then save the file as another …59571 What is SPC?
SPC is the acronym for Signal Path Compensation. SPC's. Running Signal Path Compensation corrects for DC inaccuracies caused by temperature variations and/or long-term drift. The benefit of running SPC is that is optimizes the oscilloscope's …60041 I downloaded and Installed OpenChoice Desktop, but it doesn't recognize my scope.
Refer to the Prerequisites.txt file available to download on the same page for OpenChoice desktop. Make sure you have all the prerequisites specified. Prerequisites 1. PC equipped with Microsoft Windows 7 32 Bit and 64 Bit OS, Windows 8.1 32 Bit …474266 When running SPC (signal path compensation) on my oscilloscope, I get the message that SPC failed. What does failing SPC indicate?
When an oscilloscope says SPC failed, 99.9 percent of the time it is a hardware failure that will need repair. A few things you can do before sending in for repair: Make sure all inputs (probes and cables) are removed from all the channel inputs …59621 Will the P6516 Logic Probe work on my MSO4000B, MDO4000B and MDO4000C Series oscilloscopes?
The P6516 logic probe was only used with the original MSO4000 series. For the subsequent MSO4000B, MDO4000B and MDO4000C Series oscilloscopes, the P6516 was replaced by the P6616 logic probe. The P6616 logic probe will not work on the original …246206 Which probes are compatible with oscilloscopes with the TekVPI probe interface?
There are a couple different types of TekVPI interfaces, one with a notch and one without. The notch was implemented later and was put in place because the front end was designed differently and communicates uniquely with those types of probes …56226 Why do I see 16 flat lines for the MSO digital logic inputs when the same signals are displayed properly on the analog channels and all channels are setup for valid trigger threshold levels?
A common mistake for some, we first recommend verifing that the front panel MSO digital probe is properly connected by squeezing the probe's side latch buttons to un-plug, remove the probe then re-insert the probe label side up into the front panel …60251 Why Should My Signal Fit Within The Screen Of My Tektronix Oscilloscope?
Scaling your signal to fit within the screen will remove signal distortion caused by clipping. Clipping is caused by exceeding the limits of the instrument's input. Tektronix's digital oscilloscopes are designed such that each division is 25 digital …60306 What is the maximum bit rate a decoded SPI bus can trigger on?
Different oscilloscopes have different triggering circuitry therefor the limits of what speeds can be achieved vary by scope. Please use the following table to easily look up your scope and determine your max SPI bus trigger level. For more …62256 What is aliasing?
Aliasing occurs when an oscilloscope does not sample the signal fast enough to construct an accurate waveform record. The signal frequency is misidentified, and the waveforms displayed on an oscilloscope become indistinguishable. Aliasing is …64691 What rackmount does my scope use?
Oscilloscope Family Rackmount 2 Series MSO 2-RK 3 Series MDO RM3 4 Series MSO …64571 What probe interface does my oscilloscope have?
Oscilloscope series Probe interface CSA7000/CSA7000B TekConnect DPO2000 TekVPI DPO3000 …64251 What are the primary differences between the DPO/MSO4000B, MDO4000, MDO4000B, and MDO4000C?
The 4000 Series Mixed Domain Oscilloscopes (MDO) continues to be the only true RF/Time domain syncronized instrument on the market. The major differences between revisions of the DPO/MSO/MDO4000 Series are described below. Please note the MDO4000C …72111 What is TekVISA and how can I use it to communicate with and control my instrument?
VISA is an acronym that stands for Virtual Instrument Software Architecture. In a nutshell, VISA handles the communications between your computer’s OS and the instrument. You may be familiar with TekVISA, which is Tektronix’s own brand of VISA …69176 What is the difference between the P6139A and the P6139B?
From a specifications perspective, the probes are identical. Both are 500 MHz, 10X passive probes. The P6139B can be used on oscilloscopes that shipped with the P6139A.From a mechanical perspective, there are some differences:- Sharper tip- Ground …64441 Do the existing MSO/DPO/MDO4000/B Series application modules work with the MDO4000C?
Yes, almost all work from all legacy MSO/DPO/MDO4000/B series scopes. The only one that has some requirements is the MDO4TRIG which requires a spectrum analyzer option MDO4SA3 or MDO4SA6 be installed on your MDO4000C before RF triggering capabilities …72146 How do I erase and declassify an MSO/DPO2000, MSO/DPO/MDO3000, and MSO/DPO/MDO4000 Series oscilloscope?
This example will show you how to declassify the MDO4000/B/C Series oscilloscope. This procedure also applies to the MSO/DPO4000/B, MSO/DPO/MDO3000, and the MSO/DPO2000/B series of oscilloscope.The first step in the declassification process is …66231 How do I configure the LAN settings on an MDO4000C series oscilloscope?
This procedure also applies to the DPO/MSO/MDO4000B series oscilloscopes. As it stands now, all 4000 series scopes require a live network connection be made on the scope in order to set and save LAN settings. If the scope does not have a network …66236 How can I increase the measurement accuracy using automated measurements vs cursors?
While Cursors are quick and easy at approximating measurements, using the automated measurements can give you a much better and accurate measurement results. Here are some techniques to be successful in making accurate measurements. Always use …62606 How do I use the programmer manual for my instrument?
TekVISA Download Link: TEKVISA CONNECTIVITY SOFTWARE Hello and welcome to Tektronix, today I’m presenting the last part in the 3-part series on using TekVISA. I’ll be giving a basic overview of programmer manuals and how to use them to find the …69186 How do I set up a RS232 bus decode?
The procedure to set up a RS232 bus decode and trigger is simple once you understand the basics. First you need to have the correct module or scope option. Second make sure your signal is on screen and taking up as much of the screen as possible with …64761 Can the P6139B be used on scopes that shipped with a P6139A? What is the difference between the P6139A and the P6139B?
From a specifications perspective, the probes are identical. Both are 500 MHz, 10X passive probes. The P6139B can be used on oscilloscopes that shipped with the P6139A. From a mechanical perspective, there are some differences: - Sharper tip …58111 Companies such as National Instruments and LeCroy sell USB-to-GPIB adapters. How do their adapters compare to the TEK-USB-488?
The products from National Instruments (GPIB-USB-B or GPIB-USB-HS) and LeCroy (WS-GPIB) are USB host to GPIB device adapter. These would be used for instruments that have a GPIB interface with controllers that have a USB port. The TEK-USB-488 was …56456 What is the difference between Position and Offset on an oscilloscope?
To answer this first you need to understand the layout of how your waveform trace is displayed. On your oscilloscope you generally will see either 8 or 10 divisions vertically on the screen. Along the left side of the screen you will see a marker …247211 Do you have a detailed application note on how to use DPO/MSO4000B Series Oscilloscopes for debugging embedded systems+ serial signals+ power designs+ and general purpose design applications?
Please see the MSO4000B / DPO4000B Series Lab Exercise Book for more details. This lab manual states many walk through labs that will help you under many aspects of how to use the oscilloscopes. Just download the attached lab manual. Note: Many …58161 The data sheet for my oscilloscope says that the vertical input sensitivity is 1 mV/div to 10 V/div in 1 MΩ mode. But I turn the Vertical Scale control fully clockwise and I can only get down to 10 mV/div. What am I doing wrong?
You probably aren't doing anything wrong. But you do have a 10X probe attached to that channel, right? The 1 mV/div specs relate to the oscilloscope inputs. If the signal’s source impedance is relatively low (<< 1 MOhm), the signal’s frequency is …58571 How do I utilize the math channel feature on a DPO/MSO/MDO3000 or DPO/MSO/MDO4000 Series oscilloscope?
There are three main functionalities on the Math button on this scope. They range from Dual Waveform Math, FFT (Fast Fourier Transform), and Advance Math. These three functionalities have a range of abilities and are explained in this short YouTube …64656 How do I clear my memory using TekSecure on a MSO/DPO/MDO4000 Series oscilloscope?
This procedure for clearing the memory on oscilloscope can be applied to the DPO/MSO/MDO4000, DPO/MSO3000 and DPO/MSO2000 Series oscilloscope families. By clearing the memory you will lose all saved reference waveforms, saved setups and all other …64686 Can active probes with TekProbe interface (such as a P6205) be used on the DPO4000B or MSO4000B series scopes?
Yes. A TPA-BNC adaptor is required for people to connect legacy TekProbe interface probes to the new TekVPI interface. The adapter works on any TekVPI scopes inlcuding the MSO/DPO/MDO4000/B/C, MSO/DPO/MDO3000 MSO/DPO2000/B or MSO/DPO5000/B or …60416 Can my oscilloscope operate on 400Hz power?
Most scopes have a wide range of operating voltages and frequencies, a full list can be found in the user manual of your specific oscilloscope. If you're having trouble finding your answer or can't find the manual, please call our Technical Support …63266 How do I use TekVISA to send commands to my instrument?
TekVISA Download Link:TEKVISA CONNECTIVITY SOFTWARE In order to communicate with and control the scope, you can use OpenChoice Talker-Listener. Back on the Application and Utilities panel, click on OpenChoice Talker Listener and click Start …69181 How do I set up a I2C Bus Decode?
The procedure to set up a I2C bus decode and trigger is simple once you understand the basics. First you have to have the correct module or scope option. Second make sure your signal is on screen and taking up as much of the DAC as possible with good …64756 How do I Set up a Military Standard 1553 serial bus decode?
For doing Military Standard 1553 bus decode Tektronix recommends using a DPO/MSO/MDO 2000 or higher series oscilloscope. This feature can be purchased as a module or option key on any of these types of oscilloscopes. Start by turning it on the bus …64776 How do I utilize the XY display feature on a DPO/MSO/MDO4000 Series oscilloscope?
The XY display format can be used to measure the phase relationship between two or more synchronous signals. This measurement technique involves inputting one signal into the vertical system as usual and then another signal into the horizontal system …64666 How do I set up a CAN bus decode?
Depending on the scope you have, the available options for decoding your CAN signal will depend on the compatibility. For all the DPO/MSO2000/3000/4000/5000 and MDO3000/4000 Series scopes, there are modules or license keys specifically designed for …64751 Programing - How to get and plot a waveform from DPO/MSO/MDO4000 Series scope in Python
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …64796 Programing - How do I get a Screen Capture from DPO4000 scope using Python?
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …64791 How do I connect an SMA male output to Oscilloscopes with TekVPI BNC inputs?
Use a Tektronix part number 015-0572-XX SMA female to BNC male adapter. This adapter will plug onto the BNC on the front of the scope and connect to a SMA cable. For more questions please press the "Contact Us" button on the right of the screen.63516 How do I set up a USB bus decode?
First you must have the USB module or option key that enables USB decoding for your scope as well as proper probes. For help finding the right probe use our probe selector tool. When you go into the bus option you must select USB and then make sure …64726 How can I change the TekVISA Instrument descriptor “device name” used to identify the oscilloscopes to which I routinely connect?
Open TekVISA V4.0.0+ OpenChoice Instrument Manager by selecting Start -> All Programs -> TekVISA -> OpenChoice Instrument Manager.Select (highlight) the Instrument descriptor listed in the Instruments list for the connected Oscilloscope.Click the …66181 How do I use the Save and Recall functionality of the MDO4000 series oscilloscope?
To save a screen image, go to the Save/Recall menu at the bottom of the scope. From there select the Save Screen Image softkey. This will pop up a new window with saving options. Saving a screen image requires an external memory device, such as a USB …69156 How do I download and install the 30-day trial version of NI LabVIEW SignalExpress Tektronix Edition?
Note: NI LabVIEW SignalExpress Tektronix Edition is no longer offered by Tektronix. This FAQ is "historical only".National Instruments SignalExpress Tektronix Edition is a measurement automation tool that allows SignalExpress to control a Tektronix …66221 How do I reduce noise on signals using an oscilloscope?
There are many methods to reduce many types of noise on a signal. Tektronix oscilloscopes can do this through bandwidth limiting the scope input, averaging your signal, changing the sampling method to hi-resolution mode, and more. This video …64706 How do I setup my DPO/MSO4000B to NI Signal Express?
Please click on video below.64606 How do I utilize the measurement features on a DPO/MSO/MDO3000 and DPO/MSO/MDO4000 Series oscilloscope?
The Measurements are the same as the DPO/MSO2000 Series scopes. By going into the measurement menu you can add and remove up to 4 measurements. You can gate the measurements which allows you to only measure the part of the captured waveform that you …64651 How do I save and load a reference waveform to a DPO/MSO3000 series oscilloscope?
This Video will explain how to setup, save and load a reference waveform. It can be done through a USB flash drive or by internal memory. This method for using reference waveforms can be applied to all MSO/DPO2000, MSO/DPO3000, MSO/DPO/MDO4000 …64641 How do I mount a network drive on my MDO3000 or MDO4000C oscilloscope?
This procedure also applies to the DPO/MSO/MDO4000/4000B series oscilloscopes. Note: This Mount a network drive will not work with a direct (peer-to-peer) connection. Must go through your local DNS server. To begin, press the “Menu” button in the …66201 How do I run a Signal Path Compensation (SPC) on an DPO/MSO/MDO4000 Series oscilloscope?
Signal Path Compensation (SPC) should be run anytime you are getting DC offsets in your signals, or your scope has moved locations and might have changed temperature, or if it's been more then a month since your last SPC. This is a standard procedure …64681 How Do I Set Up a Parallel Bus Decode?
For doing Parallel Bus decode Tektronix recommends using a MSO or MDO + MSO option Series oscilloscopes. This feature comes standard in the Bus menu and can be used in a variety of ways. Start by turning it on, selecting the channel and setting your …64771 How do I Set Up a LIN serial Bus decode?
For doing Local Interconnect Network (LIN) bus decode Tektronix recommends using a DPO/MSO/MDO series oscilloscope. This feature can be purchased as a module or option key on any of these types of oscilloscopes. Start by turning it on the bus channel …64781 How do I set up an Ethernet bus decode?
Make sure your setup is prepared to decode, that you have the needed probes, scope options, test boards, etc. Once you have the options it's important to know how to use the options and probe your signal. To setup Ethernet bus decoding, turn on your …64731 Are the DPO2AUTO+ DPO2COMP+ and DPO2EMBD Application Modules licensed to a specific MSO2000 or DPO2000 Series oscilloscope serial number? Are the DPO3AERO+ DPO3AUDIO+ DPO3AUTO+ DPO3COMP+ DPO3EMBD+ DPO3FLEX+ DPO3PWR+ and DPO3VID Application Modules licensed to a specific MSO3000 or DPO3000 Series oscilloscope serial number? Are the DPO4AERO+ DPO4AUDIO+ DPO4AUTO+ DPO4AUTOMAX+ DPO4COMP+ DPO4EMBD+ DPO4ENET+ DPO4USB+ DPO4LMT+ DPO4PWR+ MDO4TRIG+ and DPO4VID Application Modules licensed to a specific MDO4000, MSO4000 or DPO4000 Series oscilloscope serial number?
The application modules are not licensed to a specific oscilloscope serial number and can be swapped between the various models within the oscilloscope series.55201 My Tektronix oscilloscope uses the Linux operating system. Where do I get a copy of the linux open source code as stated in the GNU Lesser General Public License notice?
For our Linux based instruments or programs licensed under the “GNU General Public License (GPL) or Lesser GNU General Public License (LGPL)” the complete corresponding sources are available. You can order a complete machine-readable copy of the …64866 Can the P6316, P6516, or P6616 logic probes be used interchangeably?
The simple answer is no they can't be used interchangeably. The front end of the logic channels are different so different logic probes are needed between the scopes. For MSO2000/B, MSO3000, and MDO3000 Series oscilloscopes, only the P6316 logic …59166