Contact us
Call
Call us at
Available 6:00 AM – 5:00 PM (PST) Business Days
Download
Download Manuals, Datasheets, Software and more:
Feedback
Datasheets, Manuals, and Software Downloads
While we’re happy to “talk tech” with you all day long, we know you’re in a hurry.
So we’ve made it easy for you to download product manuals, datasheets and downloadable software which includes firmware, drivers, etc. for all our current products, and many discontinued products as well. Just tell us which product you’re using, and we’ll provide you with list of latest documents and resources that you can download.
The product model you have chosen is currently available for purchase. The following support information is available.
-
Datasheet Literature Number: ReleaseDate KickStart Instrument Control Software Datasheet
KickStart Software simplifies what you need to know about your instrument so that in just minutes you can take the instrument out of the box and get real data on your device. KickStart Software enables quick test setup and data visualization when …1KW-60965-13 Mixed Domain Oscilloscopes
The MDO3000 Mixed Domain Oscilloscope (MDO) Series datasheet provides an overview of the product's features, important specifications, and ordering information.48W-30020-14
-
Manuals Manual Type Part Number: ReleaseDate MDO3000 Service Manual
MDO3000 Series Mixed Domain Oscilloscopes Service ManualService Manuals 077098101 MDO3000 Series Specifications and Performance Verification Manual
MDO3000 Series Mixed Domain OscilloscopesPerformance Verification 077097900 MDO3000 Series User Manual
MDO3000 Series Mixed Domain Oscilloscope user informationPrimary User 077096802 MDO4000C, MDO4000B, MDO4000, MSO4000B, DPO4000B, and MDO3000 Series Programmer Manual
Digital oscilloscopes programming commandsProgrammer Manuals 077051009 MDO3000 Series Declassification and Security Instructions
MDO3000 Series Mixed Domain Oscilloscope Declassification and SecurityDeclassification Manuals 077098000 Update to the Latest Firmware Read This First
Update Your MDO3000 with the Latest FirmwareRelease Notes 061440200
-
Technical Documents Document Type ReleaseDate TekScope PC Waveform Analysis Flyer
Greater productivity and convenience Analyze data at your desk, at home, or on the road. Nothing to learn. It operates just like your oscilloscope. Analyze waveform data from most oscilloscopes on your PC. Remotely access your …Fact Sheet Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope
THIS APPLICATION NOTE Explains the basic setup of a mixed signal oscilloscope (MSO) Tells how to interpret the logic signal display on a Tektronix MSO Explains how to easily identify and measure setup and hold …Application Note When to Choose a Dedicated Arbitrary Function Generator (AFG)
This technical brief is written to help you determine the optimum method of arbitrary function generation for your needs. It shows examples of real-world applications and highlights key specifications of Tektronix and Keithley dedicated arbitrary …Technical Brief Analyzing Frequency Response Using the AFG31000, MDO3000, and Kickstart Software
Frequency response of a circuit is a common method of analyzing a circuit’s behavior. This application note details how Keithley’s Kickstart Software makes testing frequency response in a circuit simple, with apps for the AFG and oscilloscope and …Application Note Oxford Brookes University Case Study
Tektronix gave a team of student engineers the tools they needed to build an electric racecar, accelerating their knowledge of engineering. Read this story about how they were able to apply the principles learned in the classroom to a hands-on …Case Study Tektronix Probe Selection Guide
Oscilloscope Probes Compatibility *1 Some probes require an external power supply (1103) when used with the TDS3000 series. *2 When using with MSO / DPO2000 series, a dedicated AC adapter (119-8726-00) and a power cable (161-0342-00) are …Product Selector Guide 3 Series MDO vs. MDO3000 Series
Find more valuable resources at TEK.COM Copyright © Tektronix. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all …Fact Sheet Working Remotely with Tektronix Oscilloscopes
There are several approaches you can take to work remotely with Tektronix oscilloscopes. The available techniques differ somewhat between instruments that run the Windows operating system and instruments that do not. This guide is designed to help …Technical Brief Serial Support Using Tektronix Oscilloscopes and Optional Software
Tektronix oscilloscopes offer a portfolio of optional analysis capabilities to simplify serial bus debug or compliance verification. This selection matrix shows which serial standards are supported by each of the oscilloscope series.Product Selector Guide Probing Techniques for Accurate Voltage Measurements on Power Supplies with Oscilloscopes
This application note describes considerations and techniques for making accurate voltage measurements on power converters with an oscilloscope, especially as they relate to probe selection and application. It includes two examples for …Application Note How to Minimize Probe Loading with Low Capacitance Probes
Probing a circuit always has some impact on signals. Probe loading changes the signal being probed and can cause measurement problems or can even cause a circuit to perform differently. Reducing capacitive loading can help minimize these effects. In …Application Note Automated Frequency Response Measurement with AFG31000, MDO3000, and TekBench™ Instrument Control Software
This application note describes how to use TekBench™ Software and a Tektronix AFG31000 series arbitrary function generator and an MDO3000 oscilloscope to perform the automated frequency response measurement effortlessly within just a few steps.Application Note Measurement Data Logging with TekBench Oscilloscope Control Software
Introduction Over the last few decades, a growing number of colleges and universities have revised their approach to laboratory teaching to help students get ready to face real-world electrical engineering challenges after graduation. As part of …Application Note MDO3000 Spectrum Analyzer vs. Oscilloscope FFT Comparison Fact Sheet
MDO4000C Capabilities Not Available on Keysight N9322C 4 analog channels and 16 digital channels Function generator and DVM Serial / Parallel bus decode Capture bandwidth wide enough for …Fact Sheet Debugging Serial Buses in Embedded System Designs
Introduction Embedded systems are literally everywhere in our society today. A simple definition of an embedded system is a specialpurpose computer system that is part of a larger system or machine with the intended purpose of …Application Note How to Use a Mixed Signal Oscilloscope to Test Digital Circuits
The ability to present both analog and digital representations of signals make mixed signal oscilloscopes (MSOs) ideal for verifying and debugging digital circuits. This application note provides tips to help you efficiently debug …Application Note Wave Inspector® Navigation and Search: Simplifying Waveform Analysis
Modern digital oscilloscopes can capture massive amounts of data which must then be analyzed. Discover how the Tektronix Wave Inspector® navigation and search capability gives you the tools to extract the answers you need fast and efficiently.Application Note Accurate Measurements Matter
The MDO3000 Series scope is designed to make the most accurate measurements in the industry. While many other instruments only offer low-resolution display data, the MDO3000 takes measurements on actual acquisition data, providing an unrivaled view …Fact Sheet SOLUTIONS FOR SCIENTIFIC AND ENGINEERING RESEARCH
Brochure Making Accurate Current Measurements on Power Supplies with Oscilloscopes
This application note describes considerations and techniques for making accurate current measurements on power converters using an oscilloscope and a current probe. When used in conjunction with an oscilloscope’s voltage measurements …Application Note MDO4000C and MDO3000 Series Comparison Fact Sheet
This fact sheet compares features and specifications of MDO4000C and MDO3000 Series mixed domain oscillscopes.Product Selector Guide Power Supply Measurement and Analysis Primer
A power supply is a component, subsystem, or system that converts electrical power from one form to another; commonly from alternating current (AC) utility power to direct current (DC) power. The proper operation of electronic devices ranging from …Primer Power Supply Measurement & Analysis with Bench Oscilloscopes
Introduction Power supplies can be found in many different electronic devices, from children’s toys to computers and office equipment to industrial equipment. They are used to convert electrical power from one form to another for …Application Note Introduction to Video Measurements
In this application note, we demonstrate using a MSO/DPO5000, MDO/MSO/DPO4000 and MDO/MSO/DPO3000 Series Oscilloscope to make a variety of video measurements that are common in standard and high definition systems.Application Note Everyday Design & Debug with the MDO3000 Mixed Domain Oscilloscope
Save hours verifying and debugging your designs using a scope developed to make your job simpler and faster. Work from DC to RF, with analog and digital signals, and serial and parallel buses.Technical Brief Testing a New Switch Mode Power Supply Design Poster
Get a quick overview of the key measurements for verifying a new switch mode power supply (SMPS) design. This poster shows key measurements, from verifying your prototype during initial startup, to optimizing switching loss and magnetic losses, to …Poster MDO3000 Series vs. Keysight X3000T Series Oscilloscopes
MDO3000 - At Its Core, A Best-in-Class Scope Discover ✔ New! FastAcq high speed waveform acquisition >280,000 wfm/s ✔ New! Color-graded and Inverted waveform …Competitive MDO3000 Series vs. Agilent MSO/DSO3000 X-Series
This 2-page fact sheet compares the features and key specifications of the Tektronix MDO3000 Series oscilloscopes to the Agilent 3000 X-Series.Competitive MDO3000 Series vs. Agilent N9320B Spectrum Analyzer
Side-by-side comparison on key specifications, automated markers, plus highlights of the key features of the MDO3000:Capture bandwidthSpectogram displayIntegration with scope, logic, and protocol analysisCompetitive MDO3000 Series Product Selection and Comparison Guide
This guide helps with the selection and comparison process as you research the MDO3000. It explains key specifications for oscilloscopes, spectrum analyzers and arbitrary/function generators. It also provides a comparison template.Product Selector Guide Tektronix MDO3000 Series Oscilloscope
This demonstration guide takes you through a series of step-by-step demonstrations on how the MDO3000 Series oscilloscope helps simplify the debug of mixed signal designs with its powerful functionality and integrated test instruments. This …How-to Guide MDO Signal Path Teardown Poster
MDO4000 and MDO3000 Mixed Domain Oscilloscopes deliver uncompromised oscilloscope performance combined with spectrum analyzer performance on par with standalone spectrum analyzers. But how do they do it? The answer lies in Tektronix’ custom ASICs, a …Poster Replicating Real World Signals with an Arbitrary/Function Generator
Learn how to simulate sensor and bus signals on an arbitrary waveform generator. Find out how to capture signals using an oscilloscope, edit them using PC software, and play them back on an arbitrary/function generator.Application Note
-
Software Document Type Part Number: ReleaseDate KickStart Instrument Control Software version 2.11.2
KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of readings. • Set up a multi-instrument test with the ability to …Application KICKSTART-2.11.2 TEKVISA Connectivity Software - V5.11.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093813 KickStart Instrument Control Software version 2.11.1
KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of readings. • Set up a multi-instrument test with the ability to …Application KICKSTART-2.11.1 Tektronix Openchoice Desktop Application TDSPCS1 - V2.8
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …Utility 066093915 TEKVISA Connectivity Software - V4.2.0
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093812 DPO2000, MSO2000, DPO3000 and DPO4000, MSO3000 and MSO4000, MDO3000 and MDO4000 and MDO3 IVI Driver - V1.5
The Tektronix MSO/DPO2000, MDO/MSO/DPO3000, MDO/MSO/DPO4000 and MDO3 IVI Driver is an IVI class-compliant driver. It complies with Scope Class specifications (IVI-4.1) as defined by the IVI foundation. An IVI class-compliant specific driver for an …Driver 066133104 MDO3K FIRMWARE RELEASE - v1.30
MDO3000 firmware updateFirmware 066158611 MDO3000 FIRMWARE - V1.26
This Firmware is an upgrade for all MDO3000 Series oscilloscopes.Firmware 066158609 TEKVISA CONNECTIVITY SOFTWARE - V4.1.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093811 MDO3000 FIRMWARE - V1.24
This Firmware is an upgrade for all MDO3000 Series oscilloscopes.Firmware 066158608 Tektronix Openchoice Desktop Application TDSPCS1 - v2.6
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …Utility 066093914 MDO3000 FIRMWARE, V1.20
This Firmware is an upgrade for all MDO3000 Series oscilloscopes.Firmware 066158606 MDO3000 FIRMWARE, V1.18
This firmware is an upgrade for all MDO3000 Series oscilloscopes.Firmware 066158605 MDO3000 FIRMWARE, V1.14
This firmware is an upgrade for all MDO3000 Series oscilloscopes.Firmware 066158604 Tektronix Toolbars for Microsoft Office 32 bit - V4.0.4
Tektronix Toolbars for Microsoft Office v4.0.4 provide toolbars (add-ins) for the 32 bit versions of Microsoft Excel and Microsoft Word. This version of Toolbars requires OpenChoice TekVISA v4.0.4 (Part Number 066093809) to be preinstalled on the PC …Utility 066133202 MDO3000 FIRMWARE, V1.12
This firmware is an upgrade for all MDO3000 Series oscilloscopes.Firmware 066158603 TEKVISA CONNECTIVITY SOFTWARE, V4.0.4
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol. When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093809 ARBEXPRESS WAVEFORM CREATION AND EDITING SW, V3.1
ArbExpress is a waveform creation and editing tool for Tektronix AWG and AFG instruments. It provides an easy to use and efficient way to create and edit waveforms, transfer waveforms to and from Arbitrary Waveform Generators (AWG), and …Application 066146103
-
FAQS FAQ ID What probes are supported on the RF input of the MDO3000 and MDO4000 series?
The RF input on the MDO3000 and MDO4000 series has an N connector, so the RF input can support cables, antennas, and other adapters typically used with a spectrum analyzer. The RF input is 50 ohms and it is AC coupled. Below is a listing of some …64506 What are some of the benefits of the TekVPI probe interface?
The biggest benefits of the TekVPI™ probe interface are versatility and ease of use. Oscilloscopes with TekVPI interface support a wide range of probes including TekVPI probes, BNC and TekProbe-BNC Level 1 probes, and TekProbe-BNC Level 2 probes …56016 When should I use MagniVu on my oscilloscope?
MagniVu allows you to have higher resolution to accurately determine edge placement on your digital data. It helps you to make precise timing measurements on digital edges. On the MSO/MDO4000/B/C and MSO5000/B Series, you can see up to 32 times more …63886 What cart does my scope use?
Below are the Instrument Carts that can be purchased from Tektronix. K4000 K420 K475 More information can …64561 What's included in the MDO3000 and MDO4000C DDU option?
The Distribution Demo Unit (DDU) option on Tektronix oscilloscopes is an option provided to distributors for demoing scopes to customers with a set time limit before it expires. Questions arise about what's included in the MDO3000 and MDO4000C Series …72196 What are the maximum power draw ratings for the MDO3000 TEKVPI probes?
The MDO3000 has a max power draw of 25 Watts. The download link below provides a PDF listing of wattage draw for different active probes and max limits of Tektronix scopes, this will help determine the connection options available for any scope you …69301 Is there a mictor adapter for the P6616 (logic probe for MSO5000B, MSO4000B, and MDO4000C + MDO4MSO) or P6516 (logic probe for the MSO4000 Series) or the P6316 (logic probe for MSO2000, MSO3000, MDO3000 + MDO3MSO Series)?
A mictor adapter is available from our partner Nexus Technologies. Use the mictor adapter NEX-HD2HEADER http://www.nexustechnology.com/products/laAccessories/hd2header/59716 Why does the Tkdpo2k3k4k_ReadWaveform() function in the Tkdpo2k3k4k IVI-C driver time out every time I call it when I am connected to the instrument via Ethernet? The function call works fine over USB, but over Ethernet it always times out.
The Tkdpo2k3k4k_ReadWaveform() function makes use of the Service Request Event in VISA so the scope can notify the driver when it has completed its acquisition and the waveform data is ready to be fetched as opposed to the driver polling the scope …72221 I cannot see my signal on the Oscilloscope. What can I do?
You have many options to help diagnose this issue, below are a few suggestions to get started. If you find yourself needing more help, please connect with our Technical Support Center. You can get started by pressing the "Contact Us" button on the …63686 I could not find any information regarding the increase in bits in resolution for HiRes mode. Is there any information available?
The increase in bits in resolution depends on the decimation ratio. The decimation ratio can be determined as follows:D = MFs / FsMFs is the maximum non-interleaved sampling frequency of the scope. For example: 5 GS/s for the DPO4104B or 2.5 GS/s …55421 I downloaded and Installed OpenChoice Desktop, but it doesn't recognize my scope.
Refer to the Prerequisites.txt file available to download on the same page for OpenChoice desktop. Make sure you have all the prerequisites specified. Prerequisites 1. PC equipped with Microsoft Windows 7 32 Bit and 64 Bit OS, Windows 8.1 32 Bit …474266 If someone buys a MDO3000 with option R5 and after one year enables SA and AFG. Does the warranty option R5 apply to SA and AFG or do they have to purchase R5 for SA/AFG separately?
Yes, all extended Service options, including R5, cover the specific MDO3000 instrument for which the option was purchased. Like product warranty, Service options are linked to a specific model and serial number. Product warranty and extended Service …69311 If I upgrade my MDO3000 bandwidth do I receive higher bandwidth probes?
New, higher bandwidth probes are provided if the upgraded scope bandwidth exceeds the original supplied probes bandwidth.For example: If you upgrade a MDO3054 (500 MHz) to the MDO3104 (1GHz), you will also receive 4 TPP1000 (1 GHz probes) with the …69381 Will the DVM work on the MDO3000 series scope with a probe?
Yes, the DVM works through the analog inputs, therefor you can use standard probes. If you have more questions please contact one of our Technical Support Centers and an Application Engineer will quickly answer your questions.69331 Is the SA (Spectrum Analyzer) in the MDO3000 field upgradable?
Yes, the MDO3SA is field upgradable by customers. Any instrument can upgrade the SA input frequency to 3GHz using this quick process in the field. After inserting the SA app module in the MDO3000 the SA is enabled .The SA app module can be removed …69321 Which probes are compatible with oscilloscopes with the TekVPI probe interface?
There are a couple different types of TekVPI interfaces, one with a notch and one without. The notch was implemented later and was put in place because the front end was designed differently and communicates uniquely with those types of probes …56226 Why do I see 16 flat lines for the MSO digital logic inputs when the same signals are displayed properly on the analog channels and all channels are setup for valid trigger threshold levels?
A common mistake for some, we first recommend verifing that the front panel MSO digital probe is properly connected by squeezing the probe's side latch buttons to un-plug, remove the probe then re-insert the probe label side up into the front panel …60251 Why Should My Signal Fit Within The Screen Of My Tektronix Oscilloscope?
Scaling your signal to fit within the screen will remove signal distortion caused by clipping. Clipping is caused by exceeding the limits of the instrument's input. Tektronix's digital oscilloscopes are designed such that each division is 25 digital …60306 What is the maximum bit rate a decoded SPI bus can trigger on?
Different oscilloscopes have different triggering circuitry therefor the limits of what speeds can be achieved vary by scope. Please use the following table to easily look up your scope and determine your max SPI bus trigger level. For more …62256 What is aliasing?
Aliasing occurs when an oscilloscope does not sample the signal fast enough to construct an accurate waveform record. The signal frequency is misidentified, and the waveforms displayed on an oscilloscope become indistinguishable. Aliasing is …64691 What probe interface does my oscilloscope have?
Oscilloscope series Probe interface CSA7000/CSA7000B TekConnect DPO2000 TekVPI DPO3000 …64251 Why isn’t the TPP1000 (Tektronix Passive Probe 1GHz) compatible with my scope?
Short answer is that if your scope doesn’t have the notched key that allows the probe to connect, then the TPP probe requires a different termination resistance than what your scope can provide. Long answer is that traditionally, passive probes …467701 How do I use the serial decoder function on the MDO3000?
Hello and welcome to Tektronix, today I’m going to demonstrate the serial decoder capabilities of the MDO3000 series mixed domain oscilloscope.The MDO3000 has the ability to decode bus data into binary, hexadecimal, decimal, or ASCII values depending …69296 I recently registered our Tektronix oscilloscope, updated the firmware and am currently trying to activate the free DVM & Frequency Counter. I don’t see any software downloads for activating the DVM. Am I doing something wrong, or looking in the wrong spot?
After you have registered your oscilloscope on Tek.com, you should have received an email with instructions. The email is sent to the address you used to login to tek.com. If you haven't received the email after registration: Check your spam …468046 How do I erase and declassify an MSO/DPO2000, MSO/DPO/MDO3000, and MSO/DPO/MDO4000 Series oscilloscope?
This example will show you how to declassify the MDO4000/B/C Series oscilloscope. This procedure also applies to the MSO/DPO4000/B, MSO/DPO/MDO3000, and the MSO/DPO2000/B series of oscilloscope.The first step in the declassification process is …66231 How can I increase the measurement accuracy using automated measurements vs cursors?
While Cursors are quick and easy at approximating measurements, using the automated measurements can give you a much better and accurate measurement results. Here are some techniques to be successful in making accurate measurements. Always use …62606 How do I set up a RS232 bus decode?
The procedure to set up a RS232 bus decode and trigger is simple once you understand the basics. First you need to have the correct module or scope option. Second make sure your signal is on screen and taking up as much of the screen as possible with …64761 What is included in the Tektronix Near Field Probe kit (Tek p/n 119-4146-00) and what are they used for?
The Tektronix 119-4146-00 Near Field Probe Set is intended to serve as a versatile aid for diagnostic testing of radiated emissions over a broad range of frequencies from below 100 kHz to above 1GHz. The probe set consist of three (3) magnetic field …64501 Can existing MSO3000/DPO3000 scopes be upgraded/modified to a MDO3000?
No, there is no conversion path to go from an existing MSO/DPO3000 to a new MDO3000. If you have more questions please contact one of our Technical Support Centers and an Application Engineer will quickly answer your questions.69326 Is the MDO3000 DVM the same as making an analog channel waveform measurement?
No, the MDO3000 uses a DVM IC that takes AC+DC RMS, DC and AC RMS measurements from signal on the respective channel inputs.69371 Companies such as National Instruments and LeCroy sell USB-to-GPIB adapters. How do their adapters compare to the TEK-USB-488?
The products from National Instruments (GPIB-USB-B or GPIB-USB-HS) and LeCroy (WS-GPIB) are USB host to GPIB device adapter. These would be used for instruments that have a GPIB interface with controllers that have a USB port. The TEK-USB-488 was …56456 Is the MDO3000 free video the same as the DPO3VID.
On our past MSO/DPO3000 Series products, we had an extended video analysis module. Well, we have now made all that capability standard on the MDO3000. And the 500MHz models and below also have a native 75 Ohm input termination – the native …781581 The data sheet for my oscilloscope says that the vertical input sensitivity is 1 mV/div to 10 V/div in 1 MΩ mode. But I turn the Vertical Scale control fully clockwise and I can only get down to 10 mV/div. What am I doing wrong?
You probably aren't doing anything wrong. But you do have a 10X probe attached to that channel, right? The 1 mV/div specs relate to the oscilloscope inputs. If the signal’s source impedance is relatively low (<< 1 MOhm), the signal’s frequency is …58571 How do I utilize the math channel feature on a DPO/MSO/MDO3000 or DPO/MSO/MDO4000 Series oscilloscope?
There are three main functionalities on the Math button on this scope. They range from Dual Waveform Math, FFT (Fast Fourier Transform), and Advance Math. These three functionalities have a range of abilities and are explained in this short YouTube …64656 How do I use the Channel Monitor feature on the MDO3000 logic analyzer?
See attached PDF, which has explanations with images.69391 How do I clear my memory using TekSecure on a MSO/DPO/MDO4000 Series oscilloscope?
This procedure for clearing the memory on oscilloscope can be applied to the DPO/MSO/MDO4000, DPO/MSO3000 and DPO/MSO2000 Series oscilloscope families. By clearing the memory you will lose all saved reference waveforms, saved setups and all other …64686 Can active probes with TekProbe interface (such as a P6205) be used on the DPO4000B or MSO4000B series scopes?
Yes. A TPA-BNC adaptor is required for people to connect legacy TekProbe interface probes to the new TekVPI interface. The adapter works on any TekVPI scopes inlcuding the MSO/DPO/MDO4000/B/C, MSO/DPO/MDO3000 MSO/DPO2000/B or MSO/DPO5000/B or …60416 Can the MDO3000 capture the time domain and the frequency domain simultaneously?
The MDO3000 is most importantly an oscilloscope, but has a total of 6 different instruments individually built into it. Designed in such a way to minimize the clutter on your bench but give you the power and versatility you need. Unfortunately to be …69306 Can my oscilloscope operate on 400Hz power?
Most scopes have a wide range of operating voltages and frequencies, a full list can be found in the user manual of your specific oscilloscope. If you're having trouble finding your answer or can't find the manual, please call our Technical Support …63266 How do I use the spectrum analyzer function on the MDO3000?
Hello and welcome to Tektronix! Today I’m going to demonstrate the spectrum analyzer capability on the MDO3000 mixed domain oscilloscope. The MDO3000 contains a full-fledged spectrum analyzer with many useful features, including automatic markers, a …69281 How do I use the DVM and frequency counter function on the MDO3000?
Hello and welcome to Tektronix! Today I’m going to demonstrate the digital voltmeter and frequency counter functionality of the MDO3000 series mixed domain oscilloscope. The DVM can use any of the 4 analog scope inputs to feed the signal into a free …69286 How do I set up a I2C Bus Decode?
The procedure to set up a I2C bus decode and trigger is simple once you understand the basics. First you have to have the correct module or scope option. Second make sure your signal is on screen and taking up as much of the DAC as possible with good …64756 How do I Set up a Military Standard 1553 serial bus decode?
For doing Military Standard 1553 bus decode Tektronix recommends using a DPO/MSO/MDO 2000 or higher series oscilloscope. This feature can be purchased as a module or option key on any of these types of oscilloscopes. Start by turning it on the bus …64776 How do I utilize the XY display feature on a DPO/MSO/MDO4000 Series oscilloscope?
The XY display format can be used to measure the phase relationship between two or more synchronous signals. This measurement technique involves inputting one signal into the vertical system as usual and then another signal into the horizontal system …64666 Does Tektronix have a 12-bit oscilloscope?
Yes! Tektronix offers many different models of real-time oscilloscopes that provide 12-bit or greater vertical resolution for a variety of applications. Because many high-vertical-resolution oscilloscopes on the market have technical trade-offs such …69266 How do I use the mixed signal analysis function of the MDO3000?
Hello and welcome to Tektronix! Today I’m going to demonstrate the mixed signal capabilities of the MDO3000 series mixed domain oscilloscope.Much like its MSO predecessor, the MDO3000 boasts a 16-channel logic analyzer in addition to its 4 analog …69291 How do I set up a CAN bus decode?
Depending on the scope you have, the available options for decoding your CAN signal will depend on the compatibility. For all the DPO/MSO2000/3000/4000/5000 and MDO3000/4000 Series scopes, there are modules or license keys specifically designed for …64751 My company purchased a Tektronix MDO4104C oscilloscope last year and we purchased three application modules. They are not showing up on our scope anymore and we would like some help getting them back.
Push Utility on the front panel. If needed, push Utility Page on the lower menu and turn multipurpose knob a to select Config. Push Manage Modules and Options on the lower menu, and then push License Type on the side menu until “Modules” is selected …468031 Programing - How to get and plot a waveform from DPO/MSO/MDO4000 Series scope in Python
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …64796 Programing - How do I get a Screen Capture from DPO4000 scope using Python?
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …64791 How do I connect an SMA male output to Oscilloscopes with TekVPI BNC inputs?
Use a Tektronix part number 015-0572-XX SMA female to BNC male adapter. This adapter will plug onto the BNC on the front of the scope and connect to a SMA cable. For more questions please press the "Contact Us" button on the right of the screen.63516 How do I set up a USB bus decode?
First you must have the USB module or option key that enables USB decoding for your scope as well as proper probes. For help finding the right probe use our probe selector tool. When you go into the bus option you must select USB and then make sure …64726 How can I change the TekVISA Instrument descriptor “device name” used to identify the oscilloscopes to which I routinely connect?
Open TekVISA V4.0.0+ OpenChoice Instrument Manager by selecting Start -> All Programs -> TekVISA -> OpenChoice Instrument Manager.Select (highlight) the Instrument descriptor listed in the Instruments list for the connected Oscilloscope.Click the …66181 How do I reduce noise on signals using an oscilloscope?
There are many methods to reduce many types of noise on a signal. Tektronix oscilloscopes can do this through bandwidth limiting the scope input, averaging your signal, changing the sampling method to hi-resolution mode, and more. This video …64706 How do I utilize the measurement features on a DPO/MSO/MDO3000 and DPO/MSO/MDO4000 Series oscilloscope?
The Measurements are the same as the DPO/MSO2000 Series scopes. By going into the measurement menu you can add and remove up to 4 measurements. You can gate the measurements which allows you to only measure the part of the captured waveform that you …64651 How do I save and load a reference waveform to a DPO/MSO3000 series oscilloscope?
This Video will explain how to setup, save and load a reference waveform. It can be done through a USB flash drive or by internal memory. This method for using reference waveforms can be applied to all MSO/DPO2000, MSO/DPO3000, MSO/DPO/MDO4000 …64641 How do I mount a network drive on my MDO3000 or MDO4000C oscilloscope?
This procedure also applies to the DPO/MSO/MDO4000/4000B series oscilloscopes. Note: This Mount a network drive will not work with a direct (peer-to-peer) connection. Must go through your local DNS server. To begin, press the “Menu” button in the …66201 How do I run a Signal Path Compensation (SPC) on an DPO/MSO/MDO4000 Series oscilloscope?
Signal Path Compensation (SPC) should be run anytime you are getting DC offsets in your signals, or your scope has moved locations and might have changed temperature, or if it's been more then a month since your last SPC. This is a standard procedure …64681 How Do I Set Up a Parallel Bus Decode?
For doing Parallel Bus decode Tektronix recommends using a MSO or MDO + MSO option Series oscilloscopes. This feature comes standard in the Bus menu and can be used in a variety of ways. Start by turning it on, selecting the channel and setting your …64771 How do I use the MDO3000 to generate a frequency response curve?
The MDO3000 boasts a 50 MHz noise generator as a feature in the function generator, which can be used in conjunction with the wide-capture-bandwidth spectrum analyzer to produce a frequency response curve for an electronic system or device. The noise …69351 How do I Set Up a LIN serial Bus decode?
For doing Local Interconnect Network (LIN) bus decode Tektronix recommends using a DPO/MSO/MDO series oscilloscope. This feature can be purchased as a module or option key on any of these types of oscilloscopes. Start by turning it on the bus channel …64781 How do I know if an AC signal applied to the MDO3000/4000/B RF 50 Ω input is going to exceed the maximum input power rating, and cause clipping, or damage?
MDO3000, MDO4000/B Advanced Math equation will calculate the AC signal's equivalent RF power in dBm, and the automatic High measurement will determine the maximum average power level of the AC signal applied to the 50 Ω analog input channel. Caution: …69366 How do I use the arbitrary function generator on the MDO3000?
Hello and welcome to Tektronix! Today I’m going to demonstrate the function generator capability on the MDO3000 mixed domain oscilloscope. The MDO3000 contains an integrated arbitrary function generator (or AFG) that can output predefined or user …69276 How do I set up an Ethernet bus decode?
Make sure your setup is prepared to decode, that you have the needed probes, scope options, test boards, etc. Once you have the options it's important to know how to use the options and probe your signal. To setup Ethernet bus decoding, turn on your …64731 My Tektronix oscilloscope uses the Linux operating system. Where do I get a copy of the linux open source code as stated in the GNU Lesser General Public License notice?
For our Linux based instruments or programs licensed under the “GNU General Public License (GPL) or Lesser GNU General Public License (LGPL)” the complete corresponding sources are available. You can order a complete machine-readable copy of the …64866 Is the AFG (Arbitrary Function Generator) in the MDO3000 field upgradable?
Yes, the MDO3AFG is field upgradable by customers. The MDO3AFG is a "single-use" application module. This application module can enable the AFG which is already present in the instrument. After inserting the AFG app module in the MDO3000 the AFG is …69316 : Can the optional AFG in the MDO3000, MDO4000C and 5 Series MSO be set to sweep?
AFG in MDO3000, MDO4000C, and 5 Series MSO do not have sweep function. But a limited sweep may be created using the arbitrary function. Example: Create a sweep from 100 KHz to 250 KHz. ArbExpress (free software on Tek.com) select Equation Editor …474056 Can the P6316, P6516, or P6616 logic probes be used interchangeably?
The simple answer is no they can't be used interchangeably. The front end of the logic channels are different so different logic probes are needed between the scopes. For MSO2000/B, MSO3000, and MDO3000 Series oscilloscopes, only the P6316 logic …59166