Clarius Compliance DDR5 DRAM Receiver Test Solution

Datasheet

The DDR (Dual Data Rate) is a dominant and fast-growing memory technology. It offers high data transfer rates required for virtual computing applications, from consumer products to the most powerful servers. The high speed of these signals requires high-performance measurement tools. The Tektronix Clarius compliance DDR5 DRAM Receiver solution is an automated test application used to validate and debug the DDR5 designs of the DUT (Device Under Test) as per the JEDEC specifications. The solution enables you to achieve new levels of productivity, efficiency, and measurement reliability.

The Clarius compliance is a new-generation compliance test automation software platform that offers a range of features and benefits as follows:

  • High asset utilization and faster test times - Disaggregated architecture to offload analysis from the oscilloscope.
  • Easy workflow integration – Leverage REST API’s and SDK for faster automation.
  • Unified user interface for all technology standards across Transmitter and Receiver.
  • Integrated data management for results, reports, and waveforms in UI along with dashboard view.

Key features

  • Supports measurements of DDR5 DRAM receiver tests as per JEDEC specifications:
    • DQ Voltage Sensitivity Test
    • DQS Volage Sensitivity Test
    • DQS Jitter Sensitivity Test
    • DQ Rx Stressed Eye Test
  • Streamline test setup and remotely manage all instruments for simplified operation.
  • Leverage pre-built loopback scripts, edit, or even use your own for specific DUT (Device Under Test) setups.
  • Automate DUT configuration, calibration, and testing for increased efficiency.
    • Adaptive DFE optimization during the calibration.
    • Supports de-embedding for all measurements.
    • Automated calibration/test of multiple data rates in a single run.
    • Perform calibrations using Astek's PTF fixture and replica channel cards for flexible calibration and test setups.
  • Simulate real-world channel impairments using external ISI channels for ultimate reliability.
  • Gain immediate insights with clear, concise results – no BERT or DDR5 expertise is required.
  • Perform comprehensive sweeps, generate bathtub plots, and analyze margins for in-depth optimization.
  • Automate complex testing routines and recall them for consistent, time-saving execution.
  • Supports single rank and dual rank devices.
  • Enhanced debug capability for DUT initialization, Skip Loopback and pause before Phase change.
  • BERT offset calibration for VRef DQ settings.
  • Offset calculation methods support both the average offset across all phases and individual phase offset calculations.

Effortless test setup

Simplified measurement setup

  • User-friendly configuration options streamline the setup process for all receiver measurements.
  • Remote instrument control: Remotely control all test instruments including Anritsu’s MP1900A BERT, Astek’s fixtures for simplified operation.
  • Automated DUT (Device Under Test) management: The Clarius DDR5 DRAM Rx compliance software automatically programs your DUT into the appropriate loopback mode for each test by saving your valuable time.

Customizable loopback scripts

  • Pre-built script library: Leverage our library of pre-configured loopback scripts to quickly match common DUT configurations. Save time and effort by starting with a tested foundation.
  • Effortless customization: Easily modify these pre-built scripts to perfectly align with your specific DUT requirements.
  • Ultimate control: For highly specialized DUTs, take full control by loading and running your custom loopback scripts within the Clarius DDR5 DRAM Rx compliance framework.
Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
Custom loopback scripts

Seamless calibrations

The Clarius DDR5 DRAM Rx compliance solution streamlines the calibration process, ensuring efficient and accurate testing. Automated calibration procedures guide you through the setup for both Astek's PTF fixture and replica channel cards.

Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
DDR5 DRAM Rx Calibration

Calibration results are conveniently stored within the software, readily accessible for current and future DDR5 receiver DUT testing.

Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
DQ Voltage Calibration plot

DDR5 DRAM RX Tests

The Clarius DDR5 DRAM Rx solution streamlines the compliance testing process for DDR5 systems and devices, empowering user to achieve faster time-to-market with several innovative features.

Experience a user-friendly, step-by-step interface that accelerates test setup. Effortlessly configure key settings such as data rate, calibration, and test in a single intuitive global configuration window.

The interface groups tests logically by category like DQS Voltage sensitivity, DQ voltage sensitivity, DQS Jitter sensitivity and Stressed eye test and allows for individual test selection.

Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
LIst of Tests

DUT (Device Under Test) Initialization: This option allows the user to enable/disable the Skip DUT Initialization. When enabled, it Pauses test execution for the user to manually initialize the DUT and continues with Loopback and tests.

Skip Loopback: This option allows the user to enable/disable the Skip Loopback. When enabled, it Pauses test execution for the user to manually put DUT into Loopback and continues with tests.

Pause Before Phase Change: This option allows the user to enable/disable the Pause Before Phase Change. When enabled, it Pauses test execution before running each phase.

Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
DRAM RX Debug

Embed and De-embed filters

The Clarius DDR5 DRAM Rx compliance solution simplifies de-embedding filter management, allowing you to incorporate filter files (created by Tektronix's SDLA software) to account for PCB trace, package model, cable, and a portion of the PTF trace. This ensures the most accurate characterization of your DDR receivers, delivering reliable results for confident decision-making.

Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
De-emded filters

Specifications

Results and Report

The Clarius DDR5 DRAM Rx compliance solution simplifies result analysis, saving your valuable time and effort.

Automated configuration: The software automatically applies the correct measurement configurations and JEDEC pass/fail limits based on your chosen memory specification and speed grade.

Clear & Concise results: Gain immediate insights with easy-to-understand measurement results; no specialized BERT or DDR5 expertise is required.

Actionable insights at a glance: Quickly visualize performance through comprehensive graphical reports, including bathtub and sweep curves.

Detailed documentation: Generate in-depth reports with all plots, data tables, and relevant information for clear documentation and analysis.

Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
Stressed Eye - Bathtub curve
Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
Measurement report

Advanced analysis and margin optimization

The Clarius DDR5 DRAM Rx compliance solution empowers you to go beyond basic compliance testing and unearth valuable insights for optimizing your designs.

Advanced analysis: Leverage our advanced mode for comprehensive parameter sweeps on all measurements, including stressed eye testing. Generate insightful bathtub plots to pinpoint issues and identify areas for margin improvements.

Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
Bathtub plot for sweep amplitude

Seamless switching: Effortlessly switch between compliance and advanced modes within the same application, allowing you to efficiently perform standard testing and in-depth analysis as needed.

Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
Configuration: Advanced mode

Real-world margin analysis: Take your testing a step further by incorporating external ISI channels. This simulates real-world channel impairments, providing a more accurate assessment of receiver margins for ultimate reliability.

Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
Stressed eye calibration: ISI channels

Import sequence

Save time and effort by creating reusable sequences that automate complex testing routines. Run receiver calibration and tests at various data rates, all in one go. Simply recall the sequence whenever needed, streamlining your testing process, and ensuring consistency.

Clarius Compliance DDR5 DRAM Receiver Test Solution 61W741270
Import sequence

Ordering information

Hardware requirements

ItemDescriptionQuantityTypeVendorRequirement
DPO72304DX or MSO72304DX or DPO72304SXReal Time Oscilloscope with Bandwidth ≥ 23 GHz, Windows 10 OS1EquipmentTektronixRequired
Bit Error Rate Tester (BERT)MP1900A1EquipmentAnritsuRequired
3 Channel Programmable Power Supply for powering fixtures2230-30-31EquipmentKeithleyRequired
Host PC or LaptopRefer to system requirements for configuration-PC or Laptop-Required
USB Vector Network Analyzer, 1 MHz - 8 GHzMS46122B1EquipmentAnritsuRecommended

Test fixtures and accessories

ItemDescriptionQuantityTypeVendorRequirement
CTC2 Test FixtureA9-CTC2-011FixtureAstekRequired
Parametric Test Fixture (PTF) for calibrationA9-DIMM5-011FixtureAstekRequired
Astek Reset Automation KitA9-AUTO-011FixtureAstekRequired
DDR5 Replica Channel CardA9-RPLC-011FixtureAstekRequired
SMA-SMA, 1-meter, phase matched cable pairPMCABLE1M4AccessoryTektronixRequired
SMA-SMP adaptor, right angle (pair)174-6657-014AccessoryTektronixRequired
ISI boardJ1800A/J1758A1FixtureAnritsuOptional
Precision Fixed Attenuator, 41 Series, DC to 26.5 GHz, 6 dB attenuation41KC-63AccessoryAntirsuRequired

Software requirements

Compliance
ItemDescriptionQuantityTypeVendorRequirement
Clarius compliance DDR5 DRAM Rx software. Refer to License options.DDR5 DRAM RX1OptionTektronixRequired
Debug
ItemDescriptionQuantityTypeVendorRequirement
Serial Data Link Analysis for Windows 64-bit oscilloscopes.SDLA641OptionTektronixRequired
DPOJET Jitter Analysis.DJA1OptionTektronixRequired

System requirements

The following table shows the minimum system requirements to install and run the Clarius compliance DDR5 Rx.

Pre-requisitesRecommended requirements
Operating system

  • Windows 10 Enterprise and Pro (version 21H1 and above) or
  • Windows 11 Enterprise and Pro (version 21H2 and above)

Language: English (United States) only.

CPU cores16
RAM 64 GB
Disk space300 GB HDD/SSD of free disk space
Internet speed≥ 50 Mbps
BrowserGoogle Chrome or Microsoft Edge
Additional software
  • Python 3.12.x 1
  • BERT Firmware version MX190000A_VER_10_01_02 or above.

License options

Clarius DDR5 DRAM Rx software options

License termsLicense optionDescription
SubscriptionAT-DDR5-Rx-NS1Clarius DDR5 Rx Automation; Node-locked, Subscription, 1 Year
AT- DDR5-Rx-NS3Clarius DDR5 Rx Automation; Node-locked, Subscription, 3 Years
AT- DDR5-Rx-FS1Clarius DDR5 Rx Automation; Floating, Subscription, 1 Year
AT- DDR5-Rx-FS3Clarius DDR5 Rx Automation; Floating, Subscription, 3 Years