Datasheets, Manuals, and Software Downloads
While we’re happy to “talk tech” with you all day long, we know you’re in a hurry.
So we’ve made it easy for you to download product manuals, datasheets and downloadable software which includes firmware, drivers, etc. for all our current products, and many discontinued products as well. Just tell us which product you’re using, and we’ll provide you with list of latest documents and resources that you can download.
The product model you have chosen is a discontinued product, and the following support information is available.
-
Datasheet Literature Number: ReleaseDate TLA7000 Logic Analyzers
52W-15053-22
-
Manuals Manual Type Part Number: ReleaseDate TLA7016
Tektronix Logic Analyzer Declassification and SecurityDeclassification Manuals 077004100 TPI.NET Instructions
TIP.NETProgrammer Manuals 077135300 TLA700/7000 Series
Tektronix Logic Analyzer Declassification and SecurityDeclassification Manuals 077003702 Tektronix Supplemental, 071329504
Product Information Sheet for the People‚s Republic of ChinaUser Manuals 071329504 TLA7BXX Series
Logic Analyzer Modules Declassification & Security InstructionsDeclassification Manuals 077014601 Tektronix Logic Analyzer Family
Product Safety & Compliance InstructionsCombined User/Service 071259106 Tektronix Logic Analyzer Family
Product Safety & Compliance InstructionsCombined User/Service 071259105 TLA7000 Series
Logic Analyzers Installation ManualCombined User/Service 077174706 Tektronix Logic Analyzer Family
Product Safety & Compliance InstructionsCombined User/Service 071259104 Tektronix
Logic Analyzer Family Quick Start User ManualPrimary User 077157506 TLA7ACx
Tektronix Logic Analyzer Module Service ManualService Manuals 077015801 Tektronix Logic Analyzer
Online Help Online HelpHelp Files 077003207 TLA7BXX Series Specifications and Performance Verification Manual
Logic AnalyzersProduct Specifications & Performance VerificationPerformance Verification 077014801 020-2664-01
TLA6400 Series Logic Analyzer & TLA7012 Portable Mainframe Rackmount Kit InstructionsField Install Instructions 071175001 Tektronix Logic Analyzer Family
Product Safety & Compliance InstructionsCombined User/Service 071259103 Tektronix Logic Analyzer
Online Help Online HelpHelp Files 077003206 Tektronix Logic Analyzer Series
Product Specifications & Performance Verification Technical ReferencePerformance Verification 077176303 Tektronix Logic Analyzer
Online Help Software Version 5.8 Online HelpHelp Files 077003205 TLA Family
Product Safety & Compliance InstructionsCombined User/Service 071259102 TLA7000 Series
Logic Analyzers Installation ManualCombined User/Service 077174705 TLA Pattern Generator Programmatic Interface, Rev A
PPI Online Help Online HelpHelp Files 077039600 TLA Programmatic Interface, Rev A
TPI Online Help Online HelpHelp Files 077039700 TLA7BXX
Logic Analyzer Modules Service ManualService Manuals 077014700 TLAScript, Rev A
Graphical Interface Online HelpHelp Files 077003400 TLA7KUP
Logic Analyzer Field Upgrade Kit InstructionsField Install Instructions 077174904 TLA7KUP Instructions
Logic Analyzer Field Upgrade Kit InstructionsField Install Instructions 071174903 TLA7012 Rev A
Tektronix Logic Analyzer Declassification and Security InstructionsDeclassification Manuals 077003900 TLA7000 Series Installation Manual
Logic Analyzers Installation ManualUser Manuals 071174703 TLASWUP Instructions
Software Installation InstructionsField Install Instructions 075086003 TLA708EX TekLink Instructions
8-Port Instrument Hub and Expander InstructionsUser Manuals 071176501 TLA7000 Series Technical Reference
Mainframe Technical ReferenceService Manuals 071176400 020-2369-02 Instructions
TLA72X, TLA7XM, TLA7016 Benchtop Mainframe Rackmount Installation InstructionsField Install Instructions 071089701 020-2644-00 Instructions
TLA7012 Portable Mainframe Logic Analyzer Rackmount Kit InstructionsField Install Instructions 071175000
-
Technical Documents Document Type ReleaseDate Simplifying Xilinx and Altera Debug
This application note focuses on the issues and techniques that can help you become more efficient when debugging your FPGA systems.Application Note Logic Analyzer Fundamentals
Introduction Like so many electronic test and measurement tools, a logic analyzer is a solution to a particular class of problems. It is a versatile tool that can help you with digital hardware debug, design verification …Primer The Basics of Serial Data Compliance and Validation Measurements
Serial Buses - An Established Design Standard High-speed serial bus architectures are the new norm in today's high-performance designs. While parallel bus standards are undergoing some changes, serial buses are established across …Primer Command & Protocol Verification of DDR+ DDR2+ and DDR3 SDRAM
Computer memories are not the only systems that continue to demand larger, faster, lower powered and physically smaller memories. Embedded systems design applications have similar requirements. This application note highlights the power of the logic …Application Note Debugging Timing Problems with a Logic Analyzer
In today’s digital world, embedded systems designs are more complex than ever. With the use of faster speeds, lower power devices and more powerful logic, they are becoming increasingly sensitive to signal integrity issues. This application note will …Fact Sheet Cross-bus Analysis Reveals Interactions and Speeds Troubleshooting
Cross-bus analysis has become an indispensable troubleshooting methodology. This application note discusses how the powerful new logic analysis solution from Tektronix can speed your cross-bus troubleshooting requirementsApplication Note Introduction to Mixed Signal Test Solutions
As the complexity of today’s electronic designs rises with the increase in digital and serial content, the boundaries that define the optimum piece of test equipment can become unclear. Engineers are working with “mixed-signal” designs, which contain …Whitepaper Tektronix and FS2 Answer Debug Challenges for Xilinx FPGAs
In this fact sheet find out how the FS2 FPGAView software, when used with a Tektronix TLA Series logic analyzer, provides a complete solution for debugging your Xilinx FPGA and surrounding hardware.Fact Sheet Tektronix and FS2 Answer Debug Challenges for Altera FPGAs
In this fact sheet find out how the FS2 FPGAView software, when used with a Tektronix TLA Series logic analyzer, provides a complete solution for debugging your Altera FPGA and surrounding hardware.Fact Sheet Suggested Clocking Modes for Acquiring Flash and DRAM Memories with a TLA Series Logic Analyzer
An analysis of ST Microelectronics' M58WR064EB Flash memory and Micron Technology's MT48H4M16LFSynchronous DRAM shows that a fairly fast sampling speed will be required to capture all the signals of interestwith adequate resolution. The obvious …Application Note Quick Signal Integrity Troubleshooting with Integrated Logic Analyzers & Oscilloscopes
Fast product development requires fast and efficient troubleshooting of signal integrity problems. Signal integrity is a growing priority as digital system designers pursue ever-higher clock and data rates in their designs. To ensure signal integrity …Application Note Timing Error Debugging
New Designs, New HeadachesNew digital devices have become progressively more powerful by incorporating high-speed buses, subsystems, and logic families. They have also become more complex, more sensitive to signal quality, and more time consuming to …Application Note Logic Analyzer Triggering Techniques to Capture Elusive Problems
For digital designers who need to verify and debug their product designs, logic analyzers provide breakthrough triggering features that capture real-time digital system operation. This application note explains how to use logic analyzer triggering to …Application Note Understanding and Performing RapidIO Testing
RapidIO architecture delivers significantly increased transmission speeds to enable the design of next-generation networking and communications equipment, but with it comes compliance and interoperability issues. Tektronix comprehensive tool set …Application Note RapidIO Architecture: Building the Next-Generation Networking Infrastructure
RapidIO®, a high-performance, packet-switched bus technology, delivers the bandwidth, software independence, fault tolerance and low latency needed for the design of next-generation networking equipment in the communications market.Technical Brief Real-time Debugging Measures Signals Without Recompiling
Product Article Logic analyzer goes PCI Express
Product Article Serial analyzers support PCI Express 2.0
Product Article Companies Collaborate on Debug software for Altera FPGAs
Product Article Serial Analyzers Deliver Comprehensive PCIe Testing
Product Article Tektronix delivers complete DDR memory test bench
Product Article Serial Analyzers for PCIe 2.0 Provide Power Management and Cross Bus Analysis
Product Article Tektronix / FS2 - Collaboration on real-time logic debug solution for Xilinx FPGAs
Product Article Test methodologies for high-speed serial designs
Product Article Tektronix develops comprehensive test for Intel QuickPath interconnect
Product Article Select the Correct Debug Methodology for Your Altera FPGA Design
Debug can on average take up to 50% of the development time, particularly when looking for a difficult issue. We therefore need to use innovative ways to speed up the flow. Tektronix, First Silicon Solutions (FS2), and Alterahave teamed up to provide …Application Note Serial analyzers add to comprehensive PCI Express 2.0 testing
Product Article Verify and debug DDR2 memory systems
Technical Brief
-
Software Document Type Part Number: ReleaseDate TLA iView Update, V6.1.137
This is an update to the iView support that was released with TLA Software V6.1.127. It supports direct USB connections to Tektronix oscilloscopes that have a Type B USB connector. It adds iView support for these oscilloscopes: MDO4104CApplication 066043922 TLA iView update V6.1.134
This is an update to the iView support that was released with TLA Software V6.1.127. It supports direct USB connections to Tektronix oscilloscopes that have a Type B USB connector. It adds iView support for these oscilloscopes: DPO2012B, DPO2014B …Application 066043921 TLA iView update V6.1.132
This is an update to the iView support that was released with TLA Software V6.1.127. It supports direct USB connections to Tektronix oscilloscopes that have a Type B USB connector. It adds iView support for these oscilloscopes: MDO3012, MDO3014 …Application 066043920 TLA iView update V6.1.129
This is an update to the iView support that was released with TLA Software V6.1.127. It supports direct USB connections to Tektronix oscilloscopes that have a Type B USB connector. It adds iView support for these oscilloscopes: MDO4014B-3, MDO4034B …Update 066043919 TLA Application Software V6.1.127
New feature release includes data import (TDI), MSO/MDO digital channel support, iView over Ethernet, auto-threshold, single-install for PCIe3 support and other enhancements. Includes improvements to stability and functionality. See ReleaseNotes …Application 066037131 TLACAL PERFORMANCE VERIFICATION SOFTWARE V6.0.213
TLACal is calibration, performance verification and deskew adjust software for LA modules and their compatible probes.Utility 066132703 TLA7Sxx-TLA7SAxx PCI EXPRESS SUPPORT SOFTWARE V6.0.267.0
PCI Express support package used with TLA7S08, TLA7S16, TLA7SA08 and TLA7SA16 Serial Analyzer modules. Compatible with V6.0.267 TLA Application.Application 066044539 TLA7Sxx-TLA7SAxx PCI EXPRESS SUPPORT SOFTWARE, V2.4.151
PCI Express support package used with TLA7S08, TLA7S16, TLA7SA08 and TLA7SA16 Serial Analyzer modules. Compatible with V5.8.151 TLA Application.Application 066044538 TLA Application Software V6.0.267
Maintenance release includes improvements to stability and functionality. See ReleaseNotes.txt for a complete list of changes.Includes firmware updates to TLA7Ax and TLA7Bx modules.Includes iView(TM) support for Tektronix MDO4054, MDO4104, MSO72004 …Application 066037129 TLA Application Software V5.8.151
Maintenance release includes improvements to stability and functionality. See ReleaseNotes.txt for a complete list of changes.
Includes firmware updates to TLA7Ax and TLA7Bx modules.
Includes iView(TM) support for Tektronix MDO4054 …Application 066037128 DSI and CSI2 support software V1.1.025
TLA support package for use with DPHYPRE preprocessorApplication 066132701 DSI and CSI2 support software V1.0.003.1
TLA support package for use with DPHYPRE preprocessorApplication 066132700 TLA iView update
This is an update to the iView support that was released with TLA Software V5.8.027 or earlier. It supports direct USB connections to Tektronix oscilloscopes that have a Type B USB connector. It adds iView support for these oscilloscopes: TDS2001C …Update 066043918 TLA Application Software
Includes support for TLA6000 Series Logic Analyzers.Includes support for Compound Clocking (multiple clocks and qualifiers, formerly known as Advanced Clocking Mode) in the LA Setup window.Provides an updated firmware image for the TLA7Bxx modules …Application 066037122 TLA Application Software V5.6.754
Includes support for new TLA7ACx, TLA7BBx, and TLA7BC4 modules.The LA Setup window has been redesigned for improved usability.A new version of TekVISA(TM) provides significant improvements in the area of network connectivity.It cannot be installed on …Application 066037119 TLA7S08-S16 PCI EXPRESS SUPPORT SOFTWARE v2.0231.1
This is version 2.0.231.1 of the PCI Express support package used with TLA7S08 and TLA7S16 modules.Application 066044534 TLA TO RSA CONVERSION TOOL
This plug-in tool is designed to run within the TLA Application Software to convert an acquired digital I & Q signal for loading into a Tektronix Real-Time Spectrum Analyzer, or the RSAVu offline software, enabling modulation analysis to be performed …Utility 066100700 TLA APPLICATION REGISTRY PATCH
This patch should be applied to all TLA700 and TLA7000 products, and all PCs after V5.1 SP1 of the TLA Software Application (WebID 5177) has been installed. It corrects a registry setting that can cause application errors when acquiring glitches.Application 066085900 TLA APPLICATION SOFTWARE V5.1 SP1
This release is a full maintenance release of the TLA Software Application. After installing, the TLA APPLICATION REGISTRY PATCH (WebID 5360) should also be installed. This release also adds iView support for TDS1000B/TDS200B, TDS1001/TDS2004 …Application 066037106
-
FAQS FAQ ID What is the filename of the file needed to update my mainframe firmware on my TLA7016?
The file needed to update the mainframe firmware on the TLA7016 is "TLA7016.upd".56106 What is the replacement for a TLA721?
The TLA7016 is the direct replacement for the TLA721. All of the modules that work in the TLA721 will work in the TLA7016. The TLA7016 no longer has a built in PC so an external PC (like the TLA7PC1) running Windows 2000 Service Pack 4 or Windows XP …55006 What is the trigger latency between mainframes+ when a module (TLA7AA4) from the Master
TLA7Axx/TLA7NAx to TLA7Axx/TLA7NAx inter-mainframe trigger latency via TekLink cable is 161ns plus 1 sample. TLA7Axx/TLA7NAx to TLA7Axx/TLA7NAx inter-mainframe trigger via TL708EX is 186ns plus one sample.64221 What is the replacement for a TLA715?
The TLA7012 is the direct replacement for the TLA715. All of the modules that work in the TLA715 will work in the TLA7012.54996 What is the replacement for a TLA714?
The TLA7012 is the direct replacement for the TLA714. All of the modules that work in the TLA714 will work in the TLA7012.53566 What is the recommended calibrating interval for your logic analyzers? Do probes need to be calibrated?
We recommend calibrating your logic analyzer every year. Probes do not need to be calibrated.57836 What is the file format for saved data in the new TLA Application Software v5.1? Apparently+ different versions of the App SW have different formats.
The .tla file format changes from release to release. Because of this, we do not publish the .tla file format.56941 What supports and capabilities are there for RapidIO and Serial RapidIO?
The Tektronix TMS805 application support package facilitates the testing of 8 and 16-bit RapidIO rates up to 1 Gb/s. Nexus offers the NEX-SRIO support package for support up to 3.125 Gbps for their Serial RapidIO solution. Please see Nexus for …56166 What is the replacement for a TLA714?
The TLA7012 is the direct replacement for the TLA714. All of the modules that work in the TLA714 will work in the TLA7012.54991 What is the replacement for a TLA711?
The TLA7016 is the direct replacement for the TLA711. All of the modules that work in the TLA711 will work in the TLA7016. The TLA7016 no longer has a built in PC so an external PC (like the TLA7PC1) running Windows 2000 Service Pack 4 or Windows XP …54986 What's the maximum MHz Bandwidth that the P6960 Flying Leads support?
The P6960 uses single-ended lead sets, which should perform well up to 100MHz. Actual performance depends on several factors like the number of channels being probed, the length and number of ground leads, the proximity of the channels to one another …57926 What programmatic options do I have to remotely connect to the Logic Analyzer from my Windows OS.
TPI.NET - Provides great flexibility in choices for development languages. Component developers can use any language that supports .NET -- VC++, C#, VB, and others. .NET offers an easy way for developers to create components. COM/DCOM - Supports …57886 What is the Operating System on the TLA7016?
This will depend upon the computer used to control the TLA7016. Customers can use either Windows 2000 Professional or Windows XP Professional machines to control the TLA7016. The TLA7PC1 controller supplied by Tektronix ships with Windows XP …56966 What is the replacement for a TLA704?
The TLA7012 is the direct replacement for the TLA704. All of the modules that work in the TLA704 will work in the TLA7012.54981 What happens to my TLA connection when I press the RESET button on the TLA7016 Interface Module's front-panel? Is the acquired data in the modules lost?
Pressing the reset button the Interface Module will cause the network connection to be lost. When this occurs, you will need restart the TLA application and any data in the modules will be lost.56901 Is there a way to configure my TLA so that an email is sent when a trigger occurs?
Yes, follow the following steps:Enable Repetitive Run Mode Place the TLA logic analyzer in repetitive run mode by clicking on the repetitive/single run button to the right of the Run button. Access the Repetitive Properties Menu. Click on System and …57511 In the TLA Application Software when setting up my trigger+ I would like to setup a trigger event when my Group goes High or Low.
Using the Goes High or Goes Low event is only available by selecting a channel. If your group is made up of one channel then find the channel associated with the group in your channel setup. In the Power Trigger clause definition choose "If channel" …55861 Is there a way that I can view data files acquired from my TLA on my PC?
The latest TLA Application Software version 5.1SP1 has both the online and offline versions integrated into one package and can be downloaded from www.tek.com.52961 In the TLA Application can I change a channel polarity?
To Change a Channel polarity:1) In the System window, click the LA Setup button.2) Click Channel Polarity in the Table Shows box.3) Click the button under Probe Channels/Names that corresponds to the channel for which you want to change polarity.55836 In a TLA7000 series multi-frame+ why does one mainframe need to be the master?
The master mainframe controls clock distribution used for correlation and controls start/stop synchronization. The master mainframe is also used for the trigger in/out and signal in/out connections.56701 In the TLA Application how do I combine the setups from my unmerged modules into a new setup for my merged module system?
First Export the individual setups from each module. For each module open its Setup Window, go to the File menu and select Export Channel Setup. After you have exported every module setup, merge the system (Both physically and then logically by going …55841 In the TLA Application I am writing a power trigger and the program does not let me add more than four clauses in a state. I have another trigger program that lets me define up to 8 clauses per state. What trigger program rule am I breaking?
Each state is made up of one or more clauses. If you use more than four triggerevent resources in a state, you can have up to four clauses per state. If you havefour or fewer trigger event resources in a state, you can define up to 16 clausesper …55851 What is MagniView?
MagniVu data is the result of asynchronous digital oversampling architecture. This data is automatically acquired whenever you perform an acquisition. This means that, even if you specify synchronous (state) acquisition, you can view the asynchronous …57726 What is the replacement for a TLA715?
The TLA7012 is the direct replacement for the TLA715. All of the modules that work in the TLA715 will work in the TLA7012.53571 What is the filename of the file needed to update my mainframe firmware on my TLA7012?
The file needed to update the mainframe firmware on the TLA7012 is "TLA7012.upd".56101 What happens if the network goes down while I am taking an acquisition with a TLA7012 or TLAA7016 and the acquisition completes while disconnected. Can I reconnect and get my data?
If the network connection is lost, you will need to restart the TLA application and the data in the modules will be lost.56896 What is the replacement for a TLA720?
The TLA7016 is the direct replacement for the TLA720. All of the modules that work in the TLA720 will work in the TLA7016. The TLA7016 no longer has a built in PC so an external PC (like the TLA7PC1) running Windows 2000 Service Pack 4 or Windows XP …53576 What is the max system memory for TLA7012 and TLA7016 system?
These motherboards both have 2 DIMM sockets. We currently ship 1GB of memory configured as 2 x 512M. The memory can be increased to a maximum of 2GB when 1GB DIMMS become available.56946 What is maximum number of symbols that can be used?
The number of symbols is limited only by the amount of virtual memory available from Windows.61181 What is the replacement for a TLA720?
The TLA7016 is the direct replacement for the TLA720. All of the modules that work in the TLA720 will work in the TLA7016. The TLA7016 no longer has a built in PC so an external PC (like the TLA7PC1) running Windows 2000 Service Pack 4 or Windows XP …55001 The signal mapping of my on board Mictor for P6434 is not equal to the mapping required for the support package. How can I re-wire the signals to meet the support package mapping?
Nexus offers a Adapter called the NEX-HDSWIZ for re-wiring Mictor connectors on a target for connection to Tektronix P6434 High Density Probes. It provides the ability to rewire all 38 connectors. Please visit Nexus for details.56011 State VS. Timing - What is a state timing measurement or a timing measurement? What is the difference between internal and external clocking?
For a state measurement the logic analyzer is clocked by a signal from the system under test. At every valid clock, the logic analyzer takes a snapshot of the system under test. This snapshot (sample) is clocked by the system so the measurements are …57631 Is GbE necessary for the TLA Application Software or will the mainframes work with slower Ethernet infrastructure (e.g.100Mb)
GbE is not necessary. TLA7012 and TLA7016 mainframes will work with 10/100/1000 networks.56726 Will the TLA application software run on a regular PC so I can perform off-line setups and off-line analysis of data?
TLA software v5.0 and v5.1 can be loaded on a PC using Windows 2000 and XP. You will be able to perform off-line setups and off-line analysis of data as well as remote control of the TLA mainframe. TLA software v5.6 and v5.7 works only with Windows …61466 Will the files that I saved in previous versions of the TLA Application Software correctly load into v5.1?
Yes, all TLA Family save from V1.0, V1.1, V2.0, V3.0, V3.1, V3.2, V4.0, V4.2, V4.3, V4.4 or V5.0 systems will load properly on V5.1 systems.The V5.1 save files will not load onto V1.0, V1.1, V2.0, V3.0, V3.1, V3.2, V4.0, V4.2, V4.3, V4.4, or V5.0 …61456 Will the older Oscilloscope TLA7Dx and TLA7Dx modules work in the new mainframes?
Yes. The TLA7Dx and TLA7Ex Oscilloscope modules will work in the TLA7012 and the TLA7016. All existing TLA700 series modules will work in the new mainframes.57086 Will TLA Application Software Version 4.0 and above run under Windows 95 or 98?
No. Version 4.0 and above only operate under Windows 2000 or XP Professional.56331 Will we still have fast inter-module communications in TLA Application Software v5.1 (such as the triggers/control signals) that can be quickly communicated between modules like in previous versions of the Application SW?
Within the mainframe, the internal signaling is the same as before.57091 Is the GbE link on the TLA7012 and TLA7016 Tek proprietary or the industry standard?
The GbE ports on the TLA7012, the TLA7016, and the TLA7PC1 are compliant with industry standards.55871 Windows XP has multiple language support but is there multiple language support within the application?
The windows XP language setting applies to all standard windows dialogs and some standard Windows selection buttons. So, things like the save and open dialogs will be translated and buttons in dialogs like OK, Cancel, etc. will be translated. The TLA …57096 Is Windows XP available on any TLA?
Currently Windows XP is the operating system on TLA7012 and TLA7016 mainframes and the TLA5200B series logic analyzers.TLA5200 series can be updated with TLA5KUP Option 41. The TLA715 and TLA721 can be updated with TLA7UP option 41.57546 Will my older TLA7Lx and TLA7Mx logic analyzer modules or TLA7Dx and TLA7Ex digitizing oscilloscope modules work in the new TLA7012 portable or TLA7016 benchtop mainframes?
Yes, but you must reflash the firmware on your modules with the new Version 5.1 compatible firmware located on your TLA mainframe hard disk.If any module that is not running Version 5.1 compatible firmware is installed in a TLA mainframe running …56321 Will a DVI to VGA adapter ship with every TLA7012 mainframe?
Yes, each TLA7012 will ship with a DVI-to-VGA adapter; however, customers wishing to use an analog monitor with the TLA7012 will need to supply their own VGA cable.To use a TLA7012 with an analog monitor, the DVI cable or adapter should be attached …56316 Will the TLA Application Software v5.1 run on the 64bit version of Windows XP?
No. You need Windows 2000 professional or Windows XP Professional to run TLA Application Software v5.1.56326 Were there any improvements made to the TLATPI (Tektronix Programmatic Interface) in Version 4.4?
Please refer to the TLA Family Logic Analyzer Release Notes (ReleaseNotes.doc). If you use TLATPI on a remote machine, you must use the same version of TLA Application Software as the TPI Client Software; otherwise you may experience compatibility …61076 Will my current processor/bus support packages work with Version 5.1?
All TMSXXX support packages introduced prior to Version 5.1 have either Version 1.0, 1.1, 2.0, 3.0, 3.1, 3.2, 4.0, 4.2, 4.3, or 4.4 setup files on the factory-supplied disks that are forward compatible with Version 5.1.All TMSXXX processor/bus …61441 What is the minimum signal amplitude for P6800 or P6900 series probes+ and P6400 series probes?
The minimum signal amplitude for single ended P6800 and P6900 series probes is 300mV peak-to-peak. The minimum differential is Vmax minux Vmin >= 150mV. The minimum signal amplitude for single ended P6400 series probes is 500mV peak-to-peak.57821 What version of mainframe firmware should I have on my TLA7016?
For TLA Application Software v5.1, you should have version 5.1.187.0 for the TLA7016 mainframe.56176 What is TekLink?
It is an instrument interconnection interface. Currently TekLink 1.0 is implemented on the Logic Analyzer mainframe TLA7012 and TLA7016 for interconnection between the expansion mainframe. TekLink 2.0 is implemented on the DPO/DSA70KB. It is used …61196 What is the replacement for a TLA721?
The TLA7016 is the direct replacement for the TLA721. All of the modules that work in the TLA721 will work in the TLA7016. The TLA7016 no longer has a built in PC so an external PC (like the TLA7PC1) running Windows 2000 Service Pack 4 or Windows XP …53581 Why do I not get output on my external VGA monitor when using the DVI to VGA accessory connected to the Primary DVI-D port on the TLA7012?
The Primary DVI -D port requires a true DVI monitor. Only the SecondaryDVI -I output is compatible with VGA when using the DVIto VGA accessory that is included with the TLA7012.57046 When connected to the LAN and using the remote host mode in the TLA Application Software how does it find the mainframe or if there are several mainframes on the LAN how does it identify the specific mainframe you're looking for?
There is a connection dialog that is used that can display TLA's on the network, can search for TLA's connected to a network, or can automatically connect to a TLA of the users choice. The connection dialog shows IP address or host name of the TLA's …56186 Where can I find DDRI and DDRII support?
Nexus provides a variety of DDRI and DDRII supports including DDRII support up to 667MHz. Note: They may have faster, newer supports so please visit Nexus for their latest DDR support details.56206 Where do I find what version of TLA Application Software I currently have?
The version number can be found from within the TLA Application under System Properties in the System menu.61411 What is the filename of the file needed to update my TekLink firmware on my TLA7016 or TLA7012?
The file needed to update the TekLink firmware is "TekLink.upd".56111 What is the maximum bus width that can be monitored?
You can combine modules using the special high-speed connectors on the side of each logic analyzer module so that all channels operate from a single timebase. This is called "module merging." All channels may be contained within a single channel …61266 What is the replacement for a TLA704?
The TLA7012 is the direct replacement for the TLA704. All of the modules that work in the TLA704 will work in the TLA7012.53556 What probes can be used with the TLA7NAx+ TLA7Axx or TLA7BBx modules?
The following probes can be used with the TLA7NAx, TLA7Axx or TLA7BBx modules: P6810, P6860, P6864, P6880, P6960, P6962, P6964, P6980 and P6982.57881 What is the maximum channel group name length?
There is no limit to the channel group name length.61271 What is the current version of DSO (digitizing oscilloscope) module firmware and will I need to update it if I install Version 4.4?
The firmware version can be verified from the TLA application, system properties menu. Please refer to the TLA Family Logic Analyzer Release Notes, for the version of digitizing oscilloscope module firmware compatible with Version 5.1.61221 What version of TekLink firmware should I have on my TLA7016?
For TLA Application Software v5.1, you should have version 5.1.187.0 for the TekLink firmware on the TLA7016.56181 What is the Maximum state acquisition offered by the TLA7Axx?
The TLA7Axx offers up to 800MHz sampling rate in Half Channel mode and 625MHz DDR in quarter channel mode.57801 What is the current version of LA (logic analyzer) module firmware and will I need to update it if I install Version 5.1?
The firmware version can be verified from the TLA application, system properties menu. Please refer to the TLA Family Logic Analyzer Release Notes, for the version of digitizing oscilloscope module firmware compatible with Version 5.1.61226 Where can I find the LabView drivers for my logic analyzer?
LabView drivers are downloadable from National Instruments Instrument Driver Network. You can download them from the website or if using LabView 8.0 or later open LabView and go to Help->Find instrument Drivers and enter tktla for the keyword.56211 What is the filename of the file needed to update my mainframe firmware on my TL708EX?
The file needed to update the mainframe firmware on the TL708EX is "TL708EX.upd".56096 What is the replacement for the TLA7AAx+ TLAABx or TLA7NAx module?
The TLA7ACx is the direct replacement for the TLA7AAx, TLA7ABx or the TLA7NAx module. It comes standard with the fix channels assignment for the analog mux (the 4 BNC analog outputs). With the option AM, it will enable the fully implemented analog …60101 What is the replacement for a TLA711?
The TLA7016 is the direct replacement for the TLA711. All of the modules that work in the TLA711 will work in the TLA7016. The TLA7016 no longer has a built in PC so an external PC (like the TLA7PC1) running Windows 2000 Service Pack 4 or Windows XP …53561 What is the last supported TLA application software version for the discontinued TLA700 series such as TLA714+ TLA720+ TLA715 and TLA721?
TLA Model Last supported TLA application softwareTLA714 v4.4TLA720* v4.4TLA715 v5.1 SP1TLA721* v5.1 SP1 *note: with the upgrade kit TLA7KUP option 19, the user could upgrade the TLA720 or TLA721 to TLA7016. After the upgrade, the TLA7016 supports …61261 Where can I found an installation instruction and an oscilloscopes compatibility list for the iView cable?
In the TLA application software, go to "System" -> "Add iView External Oscilloscope" to see the list of oscilloscopes supported by the TLA and the installation instructions.60196 When you set-up a "Mark" in a TLA application V5.1 Listing or Waveform window and then add comments to it+ will the comments be included in any printouts of the data?
If you mouse over a mark header the name of the mark and the comments for the mark are shown in a tooltip. The tooltip will be captured if you print the display.56201 What happened to TLAVu?
Version 4.4 was the last version to have a separate off line viewer. The TLA software v5.0 or above no longer offer the separate TLA offline viewer. The TLA software itself has integrated with the offline data viewer. The user will need to install …54616 What is the maximum number of channel groups?
The number of channel groups is limited only by the amount of virtual memory available from Windows.61276 Why do I get a "IP read error" on the screen of my TLA?
The network factory default for the TLA7016 is DHCP. The TLA is expecting to see a DHCP server on your network and it isn't seeing one. To fix this, make sure that it can communicate with a DHCP server or set it to a static IP address. For more …57036 Does the enhanced monitor firmware need to be updated if I'm upgrading my TLA7016 from v5.0 to v5.1?
No. The enhanced monitor only needs to be updated if you are converting a TLA720 or TLA721 to a TLA7016 using TLA7UP option 19.55416 How can I enable the compound clocking in the TLA application software v5.6?
The compound clocking is not implemented in the v5.6 software yet. If you need compound clocking, you will need to use the v5.1 SP1 software. However, if you have a saved setup file created in v5.1 SP1 software, you will still be able to use the …59396 Are iView Cable Rev A and Rev B compatible with the current versions of the Application software?
Yes, both Rev. A and Rev. B of the iView Cable are compatible with the most current National Instrument driver available on the v4.4 Application CD.57116 Which oscilloscopes are included in the latest iView support?
The TLA application software with iView V6.1.132 or later, supports the following oscilloscopes:TLA iView software >> DownloadPlease contact an Application Engineer in our Support Center if you have further questions that can't be answered here or in …61416 I cannot connect to my TLA7012 or TLA7016 remotely with remote host mode.
There are a number of reasons why you might not be able to connect via the remote host mode. Perform the following checks: (TLA7012 Only) Check to determine the TLA Server is on. This is automatically turned off upon restart. You can find it in the …55776 I want the listing to show the system time when triggered in the TLA Application Software. The Timestamp does not display the hours+ minutes or seconds column.
To show the system time the Timestamp Reference must be set to Absolute. Right click the Timestamp column. Go to Properties and choose the column tab. In the Timestamp Reference Box choose Absolute. In the Listing Window move the cursor to the top …55816 I would like to get a user guide to run the TLA. Do you have a downloadable PDF file to document how to use your instrument?
Yes, you can download the latest manuals at Tektronix Manuals Finder The TLA Family Quick Start User Manual is a good reference for the TLA Series.57421 I would like to connect our Logic Analyzer to a Scope with an iView cable. This scope is not in the current list and I am not sure how to add it to the Logic Analyzer system.
Go to System Menu 'Add iView External Oscilloscope? In the next window make sure the box "Show only iVerify compatible oscilloscopes" is not selected. You should be able to select your scope from the list. Hit the Next button and you will see …57416 What is the delay of a signal out from a TLA7000 series mainframe to a scope?
This data will be published in spring 2006.56926 What is the advantage to buying a P6982 probe instead of a P6980 probe?
The P6982 is exactly the same as the P6980 except that it has only one 17-ch probe head so the total number of channels is 17 instead of 34. A customer would order the P6982 if they are only using quarter or half channels for (4x or 2x clocking). In …57741 I would like to automate the acquisitions. How can I repeatedly take acquisitions without user interaction in the TLA Application?
Repetitive Mode allows taking acquisitions repeatedly without user interaction. This can be turned on or off by either clicking on the arrow next to the run button or selecting Repetitive under System->Repetitive. You can change the settings for …55821 I want to save ink when I print a waveform. How do I change to a light background color in the waveform display?
Printing a waveform with the default dark background can use up a lot of ink. You can easily change the color scheme to a dark waveform on a light background. First, right click on a waveform in a waveform display and bring up the properties page …58431 How long does it take to update the mainframe firmware in my TLA7016?
It takes approximately 3 minutes to update the mainframe firmware.55741 How did you achieve the faster backplane in the TLA7000 series mainframes? What are you using?
We fine-tuned bus timings using a newer FPGA design and added enhanced DMA capability.56521 How does the logic analyzer implement transitional timing?
All data is sampled using the logic analyzer's internal sample clock that can be varied from the minimum sample interval of 2ns to 50 msec. Transitional Storage mode works when using either internal or external clocking. The Storage feature in the LA …60761 How do you configure the TLA7016 for use on your network?
Please refer to the TLA7000 Installation Manual for details on how to configure the TLA7016 for use on your network.56616 How long does it take to update the TekLink firmware in my TLA7016?
It takes approximately 4 minutes to update the TekLink firmware.55746 How can I get more DRAM or a bigger hard disk in my TLA704 portable and TLA711 benchtop mainframes?
You will need to utilize our mainframe trade-in program where you can trade-up to the newer TLA715 or TLA721 mainframes. Please contact your local Tektronix field representatives for further details.60651 How can I locate the MAC address of the TLA7016?
If you know the IP address of the TLA7016, you could try to following commands in the DOS prompt to look up the MAC address.c:\ pingc:\arp -aand you will see MAC address of TLA7016If you do not know the IP address of the TLA7016 … 59411 How do I check the IP address of my TLA (or any Windows 2000/XP computer)?
In Windows 2000 or Windows XP click on the "Start" button and select "Run". Type "cmd" in the box and click "Ok". At the prompt, type "ipconfig" and press "Enter". It will now show you the IP address.52541 How do I export acquired data on my TLA to ASCII?
To export data from the TLA Application, create a listing window and go to the file menu and select export. There are several options for output formats on this window including ASCII.52566 Can you disconnect someone from the TLA (i.e. if they are using remote desktop)?
No. The connection dialog will show who is connected to a TLA and disconnection requires personal interaction from that person.56446 Can I connect flying leads to my P6860+ P6880 or P6419?
Yes, Nexus has an adapter, the NEX-CFLSE & NEX-CFLDF that will allow connection between the connectorless compression probe and Tektronix probe flying leads. Please visit Nexus for details.55246 Which cart do you recommend for the TLA7016?
We recommend the K4000 for use with one TLA7016.57026 While setting up a trigger in Power Trigger mode+ how is a new state added before State 1?
Highlight state 1 in the Overview section of the trigger window. The Overview section is at the left section of the Trigger window. Right click on State 1 and "add state". New state is now after State 1. Right click on State 1 again and "cut state" …58996 Why can't I connect remotely to my TLA7012 to update the firmware?
Firmware updating for the TLA7012 needs to be done locally.56246 Why does the readout value of the counter/timers when used as a logic analyzer trigger event appear incorrect even though the logic analyzer triggered correctly?
Under certain conditions, when a counter/timer is used as a logic analyzer trigger event, the readout value displayed in the Status Monitor is incorrect even though the logic analyzer triggered correctly. The problem occurs under the following …61426 Why am I getting screen artifacts when I connect my widescreen (16:9) monitor to the DVI-I port on my TLA7PC1?
The TLA7PC1 and TLA7012 default setting for the DVI-I port is Spread Spectrum Clocking. These artifacts can be resolved by disabling the Spread Spectrum Clocking in the BIOS.53736 Do you have an application note that explains how and when to use a logic analyzer? Is there a tutorial that will show me how to use my logic analyzer?
The XYZ's of Logic Analyzers explains the evolution from the digital oscilloscope to the logic analyzer. It explains the capabilities of a logic analyzer and will you choose the correct tool for your particular application. The Introduction to …55406 Do the TLA mainframes support DHCP?
The TLA mainframes can be configured to support DHCP client capability so that when you connect the TLA to a network, it will automatically acquire an IP address and configure itself accordingly without manual intervention.If a TLA mainframe is on a …56466 Does the logic analyzer have a constant repetitive trigger mode?
Yes. Select the repetitive trigger mode by either clicking the arrow next to the RUN button or selecting System->Repetitive60586 I connected the Trigger Out from my logic analyzer to my Oscilloscope but it does not send a trigger pulse to the scope. What could be the problem with the logic analyzer?
One can turn off the System Trigger Out on the Logic Analyzer. Please check this setting from: System -> System Trigger... Check the box for Enable System Trigger Out.55791 I have connectorless compression probes (P6860+ P6880+ P6419) and need to connect to the Mictor on board. Is there an adapter to do this?
The NEX-HDSWIZ2 is used when there is a Mictor connector on a target that must be connected to Tektronix P6860, P6880 or P6419 compression probe(s). In addition to making this connection, the adapter also provides the ability to rewire the pinout …55811 It takes a long time for the TLA Connection Window in the TLA Application to find my logic analyzers. Can I speed this time up?
If your network does not have DNS it will take longer for the Application to translate hostnames into IP addresses. To eliminate this search time it is recommended to include a HOSTS file on your PC under the Windows folder->system32->drivers->etc …55916 Is it possible to save data acquired by a Logic Analyzer as an ascii-file (CSV format). I want a column with timing data+ and a column with ones and zeros.
Yes, you can save acquired data. With the Listing window currently open select export data from the File menu. This will save your acquired data as a .txt file. The data from within the .txt is taken from the Listing Window and the file format is the …57436 I do not want to store consecutive samples. How do I only store the samples that are relevant?
There are a number of ways to store only the samples that you want. Selecting storage none allows one to only store when a state explicitely says to store a sample. Transitional storage only stores a sample if one of the specified channel goups …57396 I have TLA Application Software Version 5.x and all I see in the in TLA Connection box is "Offline".
There are many things that could cause your TLA to not show up in the TLA Connection box. One of the things is if the networking is not setup correctly. 1. Verify that the TLA and the Client PC have a valid IP addresses and that they are in the same …52856 I have a Tektronix DPO or DSA Oscilloscope and a TLA running Application Software v4.4 or below and I cannot get iView to work. Are they supported?
Tektronix DPO and DSA scopes require TLA Application Software v5.1 or above for iView to work.52851 Is it possible to define several trigger conditions using the same channel(s) for these triggers?
Yes.60891 Is it possible to use iView when making a remote LAN connection to the TLA?
It is not possible to use iView when making a remote LAN connection unless you connect the scope via the USB-GPIB or directly through GPIB to the PC that is actually running the TLA Application.52906 My trigger is set to "trigger immidately" or "If anything then trigger". Why is my memory only half full?
This is because the default trigger position is set to 50% memory before the trigger and 50% memory after the trigger. Since the Logic Analyzer is triggering off the first thing it sees, it does not get a chance to fill up the first 50%. To fix …57571 For my current TLA714 portable or TLA720 benchtop mainframe+ what upgrades are necessary before I can use the new TLA7PG2 pattern generator module?
You should upgrade all of your TLA700 Series mainframes that will be used together to Version 4.0. Please order TLA7UP Option 11 or download Version 4.0 TLA Application Software for FREE. The FREE software can be located under Resources For You in …59341 The installation manual for TLA Application Software v5.1 says that I may need to update the bridge driver. How do I know if I need to or not?
If you are upgrading from v4.0 to v4.4 to v5.1, then you need to upgrade the bridge driver. If you have v5.0, then it will be upgraded automatically when you install v5.1.55996 My logic analyzer has X amount of memory depth. How many samples is this equal to?
Memory depth in a logic analyzer is the same as the number of samples. For example a module with 512Kb of memory would give you 512K (524,288) samples across every channel.57551 My memory storage is set to none and the system triggers but the program does not stop running.
In order for the acquisition to complete the entire acquisition buffer must be full. Normally when one triggers the module the rest of the buffer fills very quickly because all samples are stored until the buffer fills (storage set to all). If there …57556 In my TLA+ why does the timer keep going after I clear it?
Clear timer will always clear the timer to zero but the timer will start over and continue to run. If you want to stop the timer before starting it over then stop the timer in one state and clear the timer in the following state.57431 My Touch Screen doesn't work on my oscilloscope. How do I enable it?
The touchscreen driver is not installed or functioning properly. For customers this is most often due to the user selecting "stop installation" during the first turn on experience. The user is prompted to install the driver with a Hardware …63891 My iView cable is too short to attach the PC to the TLA7016. Do I need a different cable?
One can choose to use a TLAPC1 in these cases. The TLAPC1 is designed to be placed on top of a TLA7016 mainframe in close proximity, thus allowing usage of the iView cable in its current configuration55936 My TLA is running Windows 98. Can I upgrade the TLA SW to the latest version?
The latest version of TLA application software compatible with Windows 98 is V3.2. Version 4.4 of the application software is not compatible with Windows 98 and so the OS must be upgraded to Windows 2000 if you wish to install the latest application …57561 I get a message that says "The version of NI-488.2 for Windows does not support the obsolete GPIB-USB you are attempting to install. Contact National Instruments for details on upgrading to a new GPIB-USB revision" when I plug in the iView cable. How do I fix this?
If you get this message, you have an older GPIB-USB cable. You need to have National Instruments 488.2 software v2.3 to get this to work. It can be found on the TLA Application software v5.1 CDs. Anything greater than v2.3 will not support all …55796 Did the Performance Verification software change when TLA Application Software v5.1 was introduced?
The Performance Verification software did change a little. The software for TLA7Lx/Mx/Nx/Px/Qx and TLA7Dx/Ex modules have not been updated to run on a remote PC controller. If you need to verify one of those modules, you must do so in a TLA7012 or …55391 Is there a way to capture LVDS using a P6410+ P6417 or P6418 probe?
The LVDS/TTL to single-ended TTL converter pod will allow the customer to capture low voltage differential signals on the TLA using the P641/P6417/P6418 probe. For detailed electrical characteristic differences please contact Dragonfly Software.57506 Is there an adapter for the P6960 probe to the Mictor connector on board?
Yes, Nexus makes an adapter (NEX-M2P69X) that will allow a P6960 probe to connect to the mictor connection on the board. Please visit Nexus for details57526 Is there a new version of TLAVu? All I can find is v4.4 and v3.2.
TLAVu no longer exists. Instead, we integrate the offline data viewer into the TLA software itself. To use the offline data viewer, simply run the TLA software on the regular PC in offline mode. The latest TLA software is available at www.tek.com …52946 Is there a convenient way to functionally test logic analyzer probes?
Nexus, a partner of ours, offers an accessory called NEX-PROBETESTER2. It is compatible with P6400, P6800 and P6900 series probes and is capable of testing up to 32 data channels and a pair of clock/qualifier lines. For more information go to: …57486 Is there an adapter for connecting my connectorless compression (P6860+ P6880+ P6864+ P6419) probes to the Agilent E5378A or E5379A probe footprint?
Yes, Nexus makes adapters for connecting Tektronix P6860, P6880 and P6419 probes to Agilent probe footprints. There are different models of NEX-SAMXX adapters for both single-ended and differential probes. Please visit Nexus for details.55901 I am using a LabView client application to communicate with the Logic Analyzer but am receiving an error 1172 when I try to connect.
Please make sure you can first communicate locally from the logic analyzer. You can use one of the three example VIs that came with the tktla driver available from National Instruments. Also you need to include the TlaNetInterfaces.dll within the …55766 I am using TPI.NET to load a saved system. When I load a system the Listing Window reverts any saved changes back to the default settings. Why does it behave this way?
When a module is loaded, the TLA SW application does not assume that the new module setup will have the same channel groups as the previouse setup. Therefore all the Waveform traces and Listing columns associated with data from the previous modules …57391 Is there a way in the TLA Application Software to do performance analysis? I need to know how often my bus or group is in certain ranges.
Use the Histogram window to set up, capture, and display performance analysis data from an LA module channel group, counter, or timer. Each Histogram window displays address ranges and the corresponding counts, percentages, and histogram bars based …55891 Is there ever going to be a mechanical (new processor board) upgrade path for the TLA715?
We will not be offering a processor board upgrade for the TLA715. Current TLA715 customers can upgrade to v5.1 of the TLA Software Application and take advantage of the new remote hosted mode to use an external (faster) PC to run the TLA software …56771 Is there any way to get simultaneous LA and DSO acquisition without having to double-probe?
Yes, if you have a TLA7Axx you can use the 4 analog outputs to get simultaneous analog and digital measurements. However, the TLA7Axx is currently the only LA that supports analog and digital measurements through a single probe.The TLA7Axx iView …59731 Is there an adapter for the connectorless compression probes (P6419+ P6860+ P6880) to the mictor connector?
Yes, Tektronix makes an optional probe accessory called the 34 CH MICTOR-ON-PCB TO P6860/80 COMPRESSION ADAPTER.57521 Is there a way to stop the TLA-Connection box from popping up every time that I start my TLA?
Open up the TLA application and go to the "System" menu and select "Options". Go to the "Start-Up" tab and set "During login start TLA application" to Disable.52971 Is there an expansion mainframe available for my TLA mainframe?
Yes, the TLA7XM Expansion Mainframe which extends the TLA714 or TLA715 portable mainframe from 2 to 24 modules and the TLA720 or TLA721 benchtop mainframe from 5 to 60 modules. Please refer to the TLA700 Series section for further details.60936 Is there a way to write a Linux application to control our Logic Analyzer?
The easiest way to programmatically control a logic analyzer in a Linux/UNIX environment is with a script such as ActivePerl (a variety of Perl that has COM capabilities). If you wish to build a Linux application and have all the features of TPI.NET …55896 Is there any way to show the sample with the corresponding trigger program state in the listing or waveform?
Yes, in the TLA System Setup window add another probe group with your desired name such as State. Now add the Status Bits as the probe channels. Finally right click on the group and choose Select Status Bits Type Choose Trigger State Machine (TSM) …57541 In the TLA Application Software Listing Window I would like to know the State for each acquired sample (Trigger State Machine).
Go the the Setup window and add a new Group. Then add the status bits to this group. They are located at the bottom of the section called "Probe Channels/Names". Now right click the new Group Name for your status bits and choose "Select Status Bits …55856 Is TLA Software Application V5.1 Windows Server 2003 compliant?
We have not tested this so operation is not guaranteed. The application has been tested, and is supported on, Windows 2000 Pro and Windows XP Pro platforms (32 bit only).56776 In the TLA Application how do I load and use a symbol file into my Listing Window or Histogram?
The logic analyzer uses two kinds of symbol files: Pattern symbol files and Range symbol files. The Range symbol files can contain function symbols, variable symbols, source code symbols, and color symbols. For a more thorough explanation of Symbol …55846 TLAVu is not installing. It says I need a mainframe.
You are installing the TLA Application software and not TLAVu. Check CD #2 for TLAVu or download it from www.tek.com.57651 After installing the LabView Driver tktla the driver examples and VIs have a broken arrow and several of the subVIs have the error "Invoke Node 'Invoke Node' : contains unwired or bad terminal."
Please make sure .NET 1.1 SP1 is installed. If .NET 2.0 is also installed it is possible there is a conflict between LabView and another application. Try uninstalling .NET 2.0 and then reinstalling the tktla driver. Any VI that was saved after …55176 Are the P6810+ P6860+ P6864+ P6880+ P6960+ P6962+ P6964+ P6980+ P6982 probes compatible with our Logic Analyzer?
The P6800 and P6900 series probes are not compatible with TLA5200/B series, TLA600 series or TLA7Lx/Mx/Nx/Px/Qx Logic Analyzer modules. They are compatible with TLA7AAx/ABx/NAx/BBx modules.57126 Are there example LabView VIs available?
The National Instrument Driver tktla is available at their Instrument Driver Network. It contains three examples for using their driver. If using LabView 8.0 you will need to search for them using the NI Example Finder once the driver is installed …55211 Are channels reduced when the sample rate is 8 GHz?
No. The 8 GHz sampling provided by MagniVu is available on all channels, all of the time through the same probe simultaneous with up to 800 MHz* state timing. *Sample rate and state timing limits depend on Logic Analyzer model and ordered options.60336 Are unused clock or qualifiers usable as data inputs when sampling asynchronously or in timing mode or with an internal clock?
Yes.60396 Are all my modules supported in your TLA7000 series mainframes (TLA7012+ TLA7016)?
Yes, every logic analyzer and DSO module for the TLA700 series is compatible with the TLA7000 series mainframes.55196 I would like to design our connectorless compression (P6860+ P6880+ P6864+ P6419) probe footprints to reduce the circuit board area by half? Can the probes be modified to do this?
Yes, Nexus makes a compression probe head adapter (NEX-2X-PROBE) that allows probes to be placed on opposite sides of the board back-to-back. This reduces the circuit board area needed by half. The holes needed for a 17 channel probe can be used for …55826 Can setups and data be shared between the TLA600 Series and the TLA700 Series?
Yes, you can easily share both seteups and data.60481 Can the TLA Application Software support multi-user? (Dedicate separate modules in chassis to different users?)
No, it is not possible to split one mainframe into multiple logical mainframes.56441 My trigger program will not stop running. Why will it not trigger?
Check the status monitor to see if the program is stuck in an undesired state. Check to see if the program has triggered or reached the trigger state. Remember, a trigger program must contain a trigger or the program will not complete even if the …57576 How do I do source code correlation with a dis-assembler?
The basic process for supporting source code correlation is as follows:The user compiles their code, using a compiler switch to tell the compiler to include debug or symbolic information in the object file.At this point, the debug information is …52551 How many trigger resources can be used in a single trigger program?
A trigger program is made up of one or more states up to 16. Only one state is active at a time. Each state is made up of one or more clauses. If you use more than four trigger event resources in a state, you can have up to four clauses per state …60786 Do you have plans to support the TLA Application Software for other Operating Systems?
No. TLA Software Application V5.1 will run on Windows 2000 Pro and Windows XP Pro platforms.56471 Do the TLA700/7000 Series Logic Analyzers Series use VXI technology?
Yes, however, the TLA700/7000 Series Logic Analyzers do not allow any non TLA700/7000 modules to be used nor can the TLA700/7000 Series mainframes be used as a VXI mainframe.60541 Does an application exist to convert waveform data or .prn files to pdf or another windows format?
There are third party converters available to convert .prn files to pdf. You can find these applications by searching for them in google. All versions of TLA SW 4.2 and later (not including web install) include SnagIt which can capture a picture of …57236 How do I activate the rear panel SVGA output on the TLA714 to drive an external monitor? The Display Adapter and Display control panels do not appear to offer the option+ and the monitor I have connected to the port does not see a signal.
In order to activate an external monitor via the Secondary Video SVGA output you will need to go into the BIOS during startup. Press F2 to go into BIOS (during boot) and go to the advanced menu. Go down to "Silicon Motion Simulscan" and enable it …57286 How do I attach the connectorless compression probe to the design board?
There are two methods to connect the compression probe to the design board. One may use a Nut Block for PCB's .050'' to .093'' thick. The Nut Block may be easily removed. For PCB's .093'' to .250'' thick the Press-in Nuts are used.57296 How do I get the Tektronix DPO4000/MSO4000 Oscilloscopes to do iView with the TLA?
The DPO4000 is unique in that it needs the TEK-USB-488 along with the iView cable to make it work. To set this up you would connect the TEK-USB-488 to the DPO using the USB cable, then connect the GPIB end of the iView cable to the TEK-USB-488 and …54001 How do I set up a trigger and what resources and strategies are available for creating my own triggers?
A large number of trigger resources are available that make it possible to trigger at just the right time and store just the right data. Setting up these resources can be challenging for a new user. To minimize this effort a feature called Easy …58286 How do I rackmount my TLA mainframe?
Rackmount kits are available for the TLA600, TLA5000 and TLA700 Series. You can find order details for the rackmount kit in the TLA600, TLA5000 and TLA700 series product information data sheet. In the data sheet for the TLA5000 series, it is located …60726 How do I declassify or sanitize my instrument?
Declassification and Security documents for many Tektronix products are located in the Download, Manuals and Documentation on Tek.com. /node/7106. Enter your instrument model number and select Download Type as "Manuals". At the results screen, on …55686 How do I change my TLA7016 from a static IP address to DHCP?
If you are currently connected to the TLA7016 you can change it by opening the TLA Connection dialog (the first screen when you select the TLA Application icon). Next highlight the TLA7016 on the screen and click the "TLA Configuration" button at the …55571 How long is the Teklink cable?
2 meters56636 Have there been any changes to the TLA7QS QuickStart?
There have been no changes to the TLA7QS circuit board. The TLA7QS workbook and software setups have been updated and are still compatible with Version 3.2 or higher of the TLA application software.60626 How do I determine how much memory is installed in my Logic Analyzer?
Within the TLA Application software go to System -> System Properties -> Select LA X tab.57306 How do I change my TLA7016 from DHCP to a static IP address?
If you are currently connected to the TLA7016 you can change it by opening the TLA Connection dialog (the first screen when you select the TLA Application icon). Next highlight the TLA7016 on the screen and click the "TLA Configuration" button at the …55576 How can I get the features of the new TLA715 portable or TLA721 benchtop mainframes (e.g.+ faster CPU+ internal CD-ROM+ USB+ etc.) in my existing TLA704 portable and TLA711 benchtop mainframes?
You will need to utilize our mainframe trade-in program where you can trade-up to the newer TLA715 or TLA721 mainframes. Please contact your local Tektronix field representatives for further details.60656 How do you take a screen capture on the TLA?
SnagIt made by TechSmith comes with every current logic analyzer portable and mainframe and on the application CDs for version 4.2 of the application software and later. This tool is used for all your screen capture needs. SnagIt will allow you to …57361 How closely matched are the P6400 series probes?
The time delay specifications are the same on every P6400 series probe (P6410,P6417, P6418, P6419 and P6434 probes). This allows you to mix probe types on the same logic analyzer, thereby preserving accurate data correlation from the probe tip of …60671 How many waveforms can be displayed at one time?
The number of individual channel or busform waveforms that can be in any given Waveform window is limited only by the amount of virtual memory in the mainframe. In testing, we stopped adding waveforms at 2,000. The number of waveforms that can be …60791 How do you save a system with data?
Go to File -> Save System. Make sure the option to save acquired data is checked.57356 How do I use "ping" to check if my TLA and my computer are connected correctly?
In Windows 2000 or Windows XP click on the "Start" button and select "Run". Type "cmd" in the box and click "Ok". At the prompt, type "ping" then a space, and then the name or IP address of the computer you are trying to test connection to.52721 How much hard disk space is used by the TLA application & Windows 2000 Professional?
As delivered, your TLA700 system has approximately 1.1 GB of disk space used by the Windows operating system, utilities, and the TLA application files.60796 How do I stop/disable the TLA Application V5.1 from automatically starting up after booting the TLA?
From the TLA Application go to the System Menu->Options->Startup Tab. There is an option to Disable starting the TLA Application on login.55726 Can multiple clock sources be acquired using a single logic analyzer?
Yes, multiple clock sources can be acquired using a single logic analyzer as long as the active clock edges are the minimum sample time (either 2ns or 4ns depending on module model). *Minimum sample interval is 4ns for TLA6xx Series, TLA704 and older …60471 Can I install new modules in my TLA704 portable and TLA711 benchtop mainframes?
No. You will need to utilize our mainframe trade-in program where you can trade-up to the newer TLA715 or TLA721 mainframes. Please contact your local Tektronix field representatives for further details.60431 Can I merge my TLA700 modules?
It depends whether or not the modules are compatible and only modules with 102 or more channels can merge. The following are the basic rules for merging modules: TLA7Nx modules can be merged together, or with either TLA7Px or TLA7Qx modules. TLA7Nx …57146 Can I create a file (reference memory) in an external application and have the Logic Analyzer use the compare function with acquired data to compare the differences between the two?
The TLA Application Software cannot compare against an external source. The target has to be another saved .tla file acquired through the TLA probe interface.52386 Can V5.1 of the TLA application SW run on Linux?
No. TLA Software Application V5.1 will run on Windows 2000 Pro and Windows XP Pro platforms.55321 Can you automate control of the TLA from a Linux system?
There are a couple of options that you have depending on what you want to do. If you want to control the desktop of the TLA from your Linux box, it is suggested that you use VNC. This can be found at http://www.realvnc.com/ . If you want to …57206 Can you split the TekLink expansion hub between 2 or more multi-mainframe (Mainframe plus expansion mainframe/s) TLA systems?
No – you will need one TekLink expansion hub for each multi-mainframe system.56451 Can a data or channel group be displayed twice with different display formats?
Yes. Channels and groups may be displayed as Hex, Octal, Binary, Decimal, Signed Decimal or Symbolic. One can display a group two or more times in these formats.60401 Can I trigger on multiple busses with time correlation?
Yes, using intermodule signaling.59121 Can I install Windows XP on older TLA’s?
The TLA600 series, TLA704, TLA711, TLA714 and TLA720 are not supported for Windows XP. TLA5200 series can be updated with TLA5KUP Option 41. The TLA715 and TLA721 can be updated with TLA7UP option 41.57141 Is the name of the TLA available over TPI.NET?
No. TPI.NET does not provide the names of TLA’s on a network, nor does it provide the name of the TLA to which a client is currently connected.56741 Can you create your own trigger in the waveform trigger window in TLA application software V5.1?
No - not at this time.55326 Can the automated measurements available in TLA application V5.1 be pulled out of the LA?
Yes, there is an export button in the measurement dialog that will export the statistics table to a file of type text or csv format.55291 Can I compare two data acquisitions?
Yes, first you must define the data to compare by setting up the Define Compare dialog box. Go to the LA Setup window and then click the Compare button near the top right corner of the setup. In the Define Compare dialog box you will specify the …57136 Can a TLA be rebooted remotely?
Windows XP remote desk top (RDT) can be used to remotely reboot a machine. There is no planned way to turn on a machine remotely.56366 Could I use the qualifier channel as the external clock?
No. You can not setup the qualifier as the clock channel. However, you could plug in a different probe slot to make sure it has the clock channel instead of the qualifier channel. Both of the clock and qualifier channel could be used as a data …59191 Could the logic analyzer with less than 136 channels be used for the 4x clocking mode?
Yes. However, part of the channels on the probe head would be disable for transferring the signals and used for the storage only. If you have the TLA7 NA 4/AA4/AB4/AC4/BB4/BC4 modules, you could use the 4X demux probe P6964 which has 4 probe head …59196 How do I update the TLA firmware?
must power down the logic analyzer to allow the TLA application to start upproperly.TLA700 Series Logic Analyzers and ModulesIf you need to upgrade the firmware on your logic analyzer modules, a startupmessage appears telling you that you need to …57336 How do I get the Tektronix DPO4000/MSO4000 Oscilloscopes to do iView with the TLA?
The DPO4000 is unique in that it needs the TEK-USB-488 along with the iView cable to make it work. To set this up you would connect the TEK-USB-488 to the DPO using the USB cable, then connect the GPIB end of the iView cable to the TEK-USB-488 and …52591 How do I transfer from the logic analyzer to a VHDL or Verilog simulator?
Tektronix has added support for SynaptiCAD's products to its line of logic analyzers and pattern generators. The new Tektronix TLA600 and TLA700 Series logic analyzers can capture waveform data in a form that can be read by WaveFormer, VeriLogger …60741 Can I install new modules in my TLA714+ TLA715 portable and TLA720+ TLA721 benchtop mainframes?
Not all the current modules can be used with the older mainframes. The current modules TLA7Axx and TLA7NAx can be used in the TLA714, TLA720, TLA715, and TLA721 mainframes as long as they are running TLA Application Software v4.4 or above.However …60436 Can I boot Windows XP on my TLA7012 or TLA7PC1 from a USB attached hard drive?
Windows does not support booting from USB devices. For further information: http://www.microsoft.com/whdc/device/storage/usb-boot.mspx56376 Can the new TLA7012 and TLA7016 mainframes+ hubs+ computer+ etc be mounted in a 19” equipment rack?
Yes. Both mainframes have an optional rackmount kit. The TLA7012 rackmount kit is 020-2664-XX and the TLA7016 rackmount kit is 020-2369-XX..55296 Can the TLA assert a hardware interrupt on my target system?
Yes, using either the Trigger Out or Signal Out connectors, both of which are TTL-compatible outputs, back-terminated into 50 ohms.60521