In the TLA Application how do I load and use a symbol file into my Listing Window or Histogram?
Answer :
The logic analyzer uses two kinds of symbol files: Pattern symbol files and Range symbol files. The Range symbol files can contain function symbols, variable symbols, source code symbols, and color symbols. For a more thorough explanation of Symbol files please see the TLA Online Help topic: Symbol files.
To get started using Symbol files, there are a few examples in the "C:\Program Files\TLA 700\Samples\TLA700 Samples\Symbol Files" folder on your TLA. Open the first two files called AsciiSym.tsf and PatSym.tsf in WordPad to see an example of a typical Pattern symbol file. Create groups for an 8 channel bus and a 4 channel bus in your TLA Application Channel Setup. Add the 8 channel and 4 channel bus to your Listing Window and take an acquisition. Select the column corresponding to the 8 channel bus. Right click and go to Properties. Select the Column Tab and at the bottom is a section for choosing the Radix. Select Symbolic and choose the asciisym.tsf symbol file and click Apply. The 8 bit pattern will change to the ASCII representation. Now do the same steps for the 4 channel bus but select the patsym.tsf symbol file. The four bit pattern will change to its Symbol names and assigned colors.
For an example of a Range Symbol file open the example called tla7qs.tsf in the same folder as the other two example symbol files. A Histogram requires this type of Symbol file. For more information on Range Symbol files see the Online Help topic "Function range symbols." To load a Range Symbol file into your Histogram choose Properties from the Histogram Window and select the Ranges tab. Where is says "Define Ranges Using" choose Symbolic.
FAQ ID 55846
View all FAQs »