질문:
GPIB commands documentation seems to be missing a way to read the noise cursor readings in mv or dB. Is there such a command?
답변:
The commands are in there, but not documented in the manual:
vari:val? "NoiseAmpCursordBCh1" returns "NoiseAmpCursordBCh1 -151.09"
vari:val? "NoiseAmpCursormVCh1" returns "NoiseAmpCursormVCh1 0.0"
Change the 1 to either 2 or 3 to get the other values.
This information has been added to the latest manual, part number 071-2104-00
이 FAQ는 다음에 적용 됩니다:
제품 시리즈 없음
제품:
FAQ ID 58221
모든 FAQ 보기 »