질문:
AFG3000: How low a duty cycle can I set on the AFG3000 series?
답변:
With the latest FW you are able to set duty cycles as low as 0.001%. If you need a lower duty cycle then follow these steps.
- Press Pulse
- Press Burst
- Select 1-Cycle
- Set a pulse period equal the pulse width plus the rise and fall time shown or set by you on the AFG3000 screen. (i.e. 50 ns + 2.5 ns + 2.5 ns)
- Set the width of the pulse to the value required. (i.e. 50 ns)
- Now press Burst / More then Trigger Interval, set Trigger Interval to the period of the pulse. (i.e. trigger interval set to 100 seconds gives 0.00000005% duty cycle)