연락처

텍트로닉스 담당자와 실시간 상담 6:00am-4:30pm PST에 이용 가능

전화

전화 문의

9:00am-6:00PM KST에 이용 가능

다운로드

매뉴얼, 데이터 시트, 소프트웨어 등을 다운로드할 수 있습니다.

다운로드 유형
모델 또는 키워드

피드백

Tektronix Logic Analyzers

TLA7Dx/Ex Digital Storage Oscilloscope Modules

이 데이터 시트의 제품은 텍트로닉스에서 더 이상 판매하지 않습니다.
리퍼브 테스트 장비에 대한 Tektronix Encore를 확인하십시오.
이러한 제품에 대한 지원보증 상태를 살펴보십시오.

TLA7Dx/Ex Digital Storage Oscilloscope Modules

Features & Benefits

  • 2/4 Channel Digitizing Oscilloscope Modules with 15 Kb Memory Depth
  • Up to 1 GHz Bandwidth Provides High-fidelity Signal Quality Measurements of Digital Signals
  • Up to 5 GS/s Sample Rate Provides High Resolution Analog Views of Digital Signals
  • Advanced Digital Oscilloscope Triggering Helps Find Elusive Analog Anomalies in Digital Signals

Applications

  • Digital Hardware Verification and Debug
  • Monitor & Measure Digital Hardware Performance

Breakthrough Solutions for Real-time Digital Systems Analysis

The TLA700 Series offers a range of digitizing oscilloscope modules that provide the acquisition capabilities of the world's best digitizing oscilloscopes, tightly integrated with the TLA700 logic analyzers. The 2 and 4 channel digitizing oscilloscope modules available in the TLA700 Series offer sample rates of up to 5 GS/s and bandwidths of up to 1 GHz, with 15 Kb memory depth per channel at all times.

The digitizing oscilloscope modules offer precise time correlation and flexible cross-triggering with other installed modules. This enables you to see the quality of critical signals time-correlated with the digital signals represented by the logic analyzer modules.

These modules offer the triggering you expect from a Tektronix digital oscilloscope: Pulse Width, Runt, Glitch, Slew Rate, Logic Pattern, Setup-and-Hold Violation, Edge and Timeout.

Characteristics

General

Number of Channels per Module -

TLA7E2: 4 channels.

TLA7D1: 2 channels.

Sample Rate -

TLA7E2: 5 GS/s on all channels.

TLA7D1: 2.5 GS/s on all channels.

Bandwidth (at probe tips) -

TLA7E2:

100 mV to 10 V range: 1 GHz.

50 mV to 99.8 mV range: 900 MHz.

20 mV to 49.8 mV range: 600 MHz.

TLA7D1:

500 MHz on all channels in all ranges.

Memory Depth - 15,000 samples per channel in all modes.

Number of Mainframe Slots Required -  2.

Vertical System

Input Sensitivity Range - 10 mV to 100 V full scale.

Vertical Resolution - 8-Bit (256 levels).

DC Gain Accuracy - ±1.5% of full scale range.

Analog Bandwidth Selections - 20 MHz, 250 MHz, and Full.

Input Coupling - AC, DC or GND.

Input Impedance Selections - 1 MΩ in parallel with 10 pF, or 50 Ω.

AC Coupled Lower Frequency Limit - ≤10 Hz when AC 1 MΩ coupled, ≤200 kHz when AC 50 Ω coupled.

Maximum Input Voltage at Probe Connector - 300 VRMS, but no greater than ±420 Vp (1 MΩ or ground input coupling).

Probe Input Characteristics

Probe Input Interface - TEKPROBE™ probe interface.

Input Loading - Less than 1 pF in parallel with 1 MΩ with either P6243 or P6245.

Usable Input Voltage Range at Probe Tip - P6243 Probe: ±8 V. P6245 Probe: ±18 V.

Acquisition System

Sample Rate Range - 200 ps to 200 ms in 1, 2.5, 5 sequence.

Timebase Accuracy - ±100 ppm over any interval ≥1 ms.

Record Length Range - 512 to 15,000 samples per channel in all modes.

Acquisition Modes - Single-shot, repetitive.

Trigger System

Trigger Modes - Normal, auto.

Trigger Position - Anywhere in the acquired record (pre-fill can be set anywhere from 0% to 100%).

Trigger Types - Edge, pulse width, timeout, glitch, runt, slew rate, logic pattern, setup-and-hold violation.

Trigger Actions - Trigger, trigger all, set signal, arm, immediate, wait for system trigger.

Edge Trigger - Conventional level driven trigger, positive or negative slope, on any channel or external trigger input. Coupling Selections: DC, AC, noise reject, HF reject, LF reject.

A000_1104-N

Edge trigger.

Pulse Width Trigger - Triggers on width of positive or negative pulse, either within or not within selectable time limits; settable from 2 ns to 1 s.

A000_1105-N

Pulse Width trigger.

Timeout Trigger - Triggers when a pulse fails to complete when specified; settable from 2 ns to 1 s.

A000_1106-N

Timeout trigger.

Glitch Trigger - Triggers on (or rejects) glitches of positive, negative, or either polarity; settable from 2 ns to 1 s. Minimum glitch width: 2.0 ns, with 200 ps resolution (2 ns to 10 ns settings).

A000_1107-N

Glitch trigger.

Runt Pulse Trigger - Triggers on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again; settable from 2 ns to 1 s.

A000_1108-N

Runt Pulse trigger.

Slew Rate Trigger - Triggers on pulse edge rates that are either faster or slower than a set rate, edges can be rising, falling, or either; settable from 2 ns to 1 s.

A000_1109-N

Slew Rate trigger.

Logic Pattern Trigger - Triggers when a logical combination (AND, OR) of all the input channels (Hi, Lo, Don't Care) stays true or false for a specified period of time; settable from 2 ns to 1 s.

A000_1110-N

Logic Pattern trigger.

Setup-and-hold Trigger - Triggers on violations of both setup time and hold time between clock and data which are on separate input channels; setup time settable from -100 ns to +100 ns in 200 ps increments; hold time settable from -1 ns to +102 ns; minimum settable window of setup time + hold time is 2 ns.

A000_1111-N

Setup-and-hold trigger.

Safety - CSA C22.2 No. 1010.1, EN61010-1, IEC61010-1, UL 3111-1.

Physical

Physical Characteristics

Dimensions

mm

in.

Weight

kg

lb.

Height

262

10.3

Width

61

2.4

Depth

381

15

Net

2.7

5.8

Shipping

5.8

12.8

P6243 Probe Cable Length - 1.3 m (51 in.).

P6245 Probe Cable Length - 1.3 m (51 in.).

Ordering Information

Digitizing Oscilloscope Modules

Includes: Probes, certificate of calibration, and one-year warranty (return to Tektronix), and user manual.

TLA7D1 - 2-Channel DSO module, 500 MHz bandwidth, 2.5 GS/s sample rate, 15 K depth (includes two P6243 1.0 GHz active FET probes, probe calibration adapter and manual).

TLA7E2 - 4-Channel DSO module, 1 GHz bandwidth, 5 GS/s sample rate, 15 K depth (includes four P6245 1.5 GHz active FET probes, probe calibration adapter and manual).

TLA700 Series DSO Module Upgrades

You can install a TLA7Dx/Ex digitizing oscilloscope module into an existing TLA714/715/720/721/7XM mainframe. Please refer to the TLA Family Upgrade Guide for further details.

DSO Module Accessories
A000_1112-N

P6243 - 1.0 GHz Active FET Probe and accessories, length 1.5 m.

P6245 - 1.5 GHz Active FET Probe and accessories, length 1.5 m.

P6243/P6245 Probe Accessories

Part Number

Description

003-1383-00

Compensation box and cover removal tool

003-1433-00

Adjustment tool

016-1315-00

2 each - 5 colors of cable markers

131-5638-10

10 each - solderable probe tips

131-5777-00

100 mil square pin ground adapter

196-3410-00

Ground lead set includes:

N/A

2 each - 1 in., 3 in., 6 in. ground leads w/ square pin receptacle;

N/A

2 each - Y lead adapters

196-3439-00

1 in. ground lead

206-0364-00

SMT KlipChip, 1 each

214-4227-00

Right angle square pin adapter

SF501

SureFoot® probe tip adapter, pkg. of 12, yellow, 50 mil pitch

SF502

SureFoot probe tip adapter, pkg. of 12, blue, 25 mil/0.65 mm pitch

SF503

SureFoot probe tip adapter, pkg. of 12, red, 0.5 mm pitch

SMG50

SMT KlipChip grabber tip, 20 each

SMK4

Micro KlipChip adapter, 4 each

070-9408-00

P6243 Instruction Manual

070-8995-01

P6245 Instruction Manual

TLA Family Service Option Availability

   

TLA6XX

TLA715/721

TLA7XM

TLA7Axx

TLA7NX/PX/QX

TLA7PG2

TLA7DX/EX

Opt. IN

   

X

X

X

X

X

X

Opt. R3

X

X

X

X

X

X

X

Opt. R5

X

X

X

X

X

X

X

Opt. S1

   

X

X

   

   

   

   

Opt. S3

   

X

X

   

   

   

   

Opt. C3

X

X

   

X

X

   

X

Opt. C5

X

X

   

X

X

   

X

Opt. D1

X

X

   

X

X

   

X

Opt. D3

X

X

   

X

X

   

X

Opt. D5

X

X

   

X

X

   

X

Service

Opt. C3 - Calibration Service 3 Years

Opt. C5 - Calibration Service 5 Years

Opt. D1 - Calibration Data Report

Opt. D3 - Calibration Data Report 3 Years (with Option C3)

Opt. D5 - Calibration Data Report 5 Years (with Option C5)

Opt. R3 - Repair Service 3 Years

Opt. R5 - Repair Service 5 Years

Opt. IN - Product Installation Service