On the DPO4000 and MSO4000 series+ what video trigger modes are supported?

Question :

On the DPO4000 and MSO4000 series+ what video trigger modes are supported?

Réponses :

The DPO4000 series supports 525/NTSC, 625/PAL and SECAM standards. In each case you can specify the trigger to be on odd, even or all fields or on all lines. Trigger on line number is supported starting with version 1.09.

Polarity selection, true video autoset, trigger holdoff by fields, and IRE and mV graticules are supported in firmware version 2.04.

Additional video triggering capabilities are added with the DPO4VID module. The additional formats supported are:

480P/60
576P/50
720P/30
720P/50
720P/60
875I/60
1080I/50
1080I/60
1080P/24
1080P/24sF
1080P/24
1080P/25
1080P/30
1080P/50
1080P/60
Bi-level sync custom
Tri-level sync custom