Question :
MSO4000: I have a new MSO4104 and I want to search on a logical pattern consisting of a mixture of analog and digital channels . How do I do this?
Answer :
When searching for a digital pattern, Tektronix recommends setting up a parallel bus and then searching on that parallel bus. When using logic search on digital signals, we recommend that only the analog or only the digital channels be used to acquire all clock and data signals.