Datasheets, Manuals, and Software Downloads
While we’re happy to “talk tech” with you all day long, we know you’re in a hurry.
So we’ve made it easy for you to download product manuals, datasheets and downloadable software which includes firmware, drivers, etc. for all our current products, and many discontinued products as well. Just tell us which product you’re using, and we’ll provide you with list of latest documents and resources that you can download.
The product model you have chosen is a discontinued product, and the following support information is available.
-
Datasheet Literature Number: ReleaseDate Bit Error Rate Tester
The BERTScope Bit Error Rate Tester Series provides a new approach to signal integrity measurements of serial data systems. Perform bit error rate detection more quickly, accurately, and thoroughly by bridging eye diagram analysis with BER pattern …65W-25444-15 M-PHY Receiver Solution Datasheet
GRL’s MIPI MPhy Receiver Calibration and Test Application Software for the Tektronix BERTScope™ BSA(GRL-MIPI-MPHY-RX) provides an automated, simple, and efficient way to test MIPI MPhy Receiver to the Jitter Tolerance and other test requirements of …
-
Manuals Manual Type Part Number: ReleaseDate Tektronix BERTScope
BSA & BA Remote Control Guide Programmer ManualProgrammer Manuals 077069605 Tektronix BERTScope
Bit Error Ratio Analyzers & Pattern Generators Quick Start User ManualPrimary User 071286904 Tektronix BERTScope
BSAPCI3 InstructionsUser Manuals 071304600 Tektronix BERTScope BSA Series
Declassification and Security InstructionsDeclassification Manuals 077079100 Tektronix BERTScope
BSAITS125 Declassification & Securities InstructionsDeclassification Manuals 077069500 ITSRACK
Rackmount InstructionsUser Manuals 071305100 BERTScope Analyzers
BERTScope Bitalyzer Remote Control Guide Programmer ManualProgrammer Manuals 077067700 BERTScope Analyzers
BERTScope Bitalyzer Remote Control Guide Programmer ManualProgrammer Manuals 077055400 BERTScope Analyzers
BERTScope Bit Error Ratio Analyzer Instructions Quick Start User ManualUser Manuals 077055200
-
Technical Documents Document Type ReleaseDate High Speed Interface Standards
How-to Guide Physical Layer Tests of 100 Gb/s Communications Systems
In this application note, learn how to prepare for compliance measurements on 100G standards including IEEE802.3ba/bj/bm and the tests for optical, electrical, or PAM4 transmitters and receivers that help diagnose noncompliant components and systems.Application Note USB 3.1 Receiver Compliance Testing
In this application note, all aspects of USB 3.1 receiver testing are covered, including stressed eye calibration and jitter tolerance testing with measured device margin.Application Note Practices for Measurements on 25 Gb/s Signaling
This application note describes the measurement practices for the characterization and compliance test of the transmitter and receiver for 25+ Gb/s signaling in 100 G systems. Focus is on oscilloscope measurements, with some comments on BERTs.Application Note Stress Calibration for Jitter >1UI
While measuring the amount of jitter present on a signal is relatively straight forward conceptually; when the levels of jitter are small, amounts above a bit period (1 unit interval or UI) can be more difficult. This has practical consequences for …Application Note Characterizing an SFP+ Transceiver at the 16G Fibre Channel Rate
Figure 1. An example Fibre Channel topology. Abstract The Fibre Channel standard is evolving to include the next generation "16G" data rate. Specifications show a line rate of 14 …Primer Stressed Eye Primer
Figure 1. Conceptual picture of an ideal receiver. Figure 2. Simplified Receiver Block Diagram. Abstract Many high-speed serial …Primer PCI Express® Transmitter PLL Testing — A Comparison of Methods
Abstract The electrical compliance test specification drafted by PCISIG requires testing loop response of the Phase Locked Loop (PLL) used in add-in cards to generate a local transmitter clock from a 100 MHz reference oscillator …Primer Stressed Eye: “Know What You’re Really Testing With”
BER-based measurements can provide a better view of the stress eye opening down at the deep BER levels that the receiver will be expected to operate at when it is tested.Primer Clock Recovery Primer, Part 2
Abstract Clock recovery is a common part of many measurements, whether as part of the test setup or part of the device under test. We’re going to look at clock recovery from a practical point of view, with emphasis on how it affects …Primer Clock Recovery Primer, Part 1
Figure 1. If clock and data were to move in time by the same amount at the same time, a decision circuit could remove the effect of jitter. Abstract Clock recovery is a common part …Primer Dual-Dirac+ Scope Histograms and BERTScan Measurements
Figure 1.1. Using an eye diagram to set a window around the crossing point and plot edge positions. Abstract Much has been written about the strengths and weaknesses of dual-Dirac …Primer Evaluating Stress Components using BER-Based Jitter Measurements
Figure 1.1. Self-verification stress setup - connections to a BERTScope S or BERTScope with option SE (left). Stress user interface (right) showing the addition of individual impairments …Primer BERTScope® Bit Error Rate Testers Jitter Map “Under the Hood”
Abstract Jitter Map is a capability on the BERTScope that uses BER measurements tomeasure Total Jitter as well as decompose jitter beyond basic Random and Deterministic Jitter. This paper introduces the reader to the methodologies …Application Note Exploring Power Supply Voltage Sensitivity in an IC with a BERTScope® Bit Error Rate Tester
Eye diagrams alone may not be as effective in showing major system issues and should be coupled with BER-based measurements for deeper insight and problem resolution.Application Note Exploring Power Supply Voltage Sensitivity in an IC with a BERTScope® Bit Error Rate Tester
Eye diagrams alone may not be as effective in showing major system issues and should be coupled with BER-based measurements for deeper insight and problem resolution.Application Note Comparing Jitter Using a BERTScope® Bit Error Rate Testing
Introduction In most systems, it is desirable to have each data bit have the same duration (see Figures 1(a) and 2(d)). When bits vary in length, either randomly or systematically, this is known as jitter. One traditional form of …Application Note D.C. Blocks, a Trap for the Unwary When Using Long Patterns
It is obvious to focus on ensuring that the upper frequency of the range is adequate to pass the desired data signal; while it is less obvious to worry about the low end frequency specification, this application note discusses that it can be equally …Application Note Signal Integrity of Reference Clock Bleed-Through in an IC
This application note examines some signal integrity examples related to AMB testing, but also with wider applicability. Clock bleed-through is examined, as well as the effect of a lowered supply voltage on error performance.Application Note Six Sigma’ Mask Testing with a BERTScope® Bit Error Rate Tester
Introduction Mask testing is a common method of estimating whether a transmitted waveform is of sufficient quality to meet system requirements. In most systems the requirement is to pass bits error free, or at least at better than 1 …Application Note Bridging the Gap Between BER and Eye Diagrams — A BER Contour Tutorial
Abstract This paper provides an introduction to the BER Contour measurement - what it is, how it is constructed, and why it is a valuable way of viewing parametric performance at gigabit speeds. It also provides illustrative examples …Application Note Clock Recovery’s Impact on Test and Measurement
Introduction Clock recovery plays a significant role in making accurate test measurements, whether incorporated into the test setup or as part of the device under test. As most gigabit communication systems are synchronous, the data …Application Note BSA Series BERTScope Bit Error Rate Testers Fact Sheet
This BERTScope Fact Sheet contains key specs and ordering information for the BSA Series BERTScope Bit Error Rate Testers.Fact Sheet
-
Software Document Type Part Number: ReleaseDate Tektronix Receiver Test Application Software for USB3.1 Gen1 and Gen2 - V2.3.0
USB 3.1 Gen1 and Gen2: Testing is described in the USB-IF Compliance Test Specification (CTS) document. Receiver testing is accomplished by connecting the output of a BERT pattern generator as an input to the DUT, through a specialized set of …Application 066195002 BERTScope Application Software, V11.02.1903
BERTScope(R) Analyzers are designed for applications from 500 Mb/s to 28.6 Gb/s. They are the industry`s first multi-Gb/s instruments that combine the eye diagram analysis capabilities of high-bandwidth sampling oscilloscopes together with BER …Application 066165804 BSAUSB31 USB 3.1 Receiver Test Application Software, V1.1.1907
The BERTScope USB 3.1 Receiver Test Automation Software runs on a BERTScope or PC, and connects to the BERTScope, DPP, CR, and Instrument Switch test equipment via LAN. It uses remote control automation protocols to fully automate USB 3.1 calibration …Application 066171100 BERTSCOPE APPLICATION SOFTWARE, V11.02.1886
BERTScope(R) Analyzers are designed for applications from 500 Mb/s to 28.6 Gb/s. They are the industry`s first multi-Gb/s instruments that combine the eye diagram analysis capabilities of high-bandwidth sampling oscilloscopes together with BER …Application 066165802 BSAPCI3 PCIe 3.0 Receiver Test Application Software, V1.1.1449
The PCIe 3.0 Receiver Test Automation Software (BSAPCI3) runs on a BERTScope or peripheral PC, and connects to a BERTScope and DPP (Digital PreEmphasis Processor) test equipment via LAN. It uses remote control automation protocols to fully automate …Application 066156501 BERTScope Software Release, V 10.15.1284
BERTScope(R) Analyzers are designed for applications from 500 Mb/s to 28.6 Gb/s. They are the industry`s first multi-Gb/s instruments that combine the eye diagram analysis capabilities of high-bandwidth sampling oscilloscopes together with BER …Firmware 066148402 BERTScope Software Release
BERTScope(R) Analyzers are designed for applications from 500 Mb/s to 26 Gb/s. They are the industry`s first multi-Gb/s instruments that combine the eye diagram analysis capabilities of high-bandwidth sampling oscilloscopes together with BER pattern …Application 066123808 BERTScope Driver for LabVIEW V1.0.2
BERTScope? and BERTScope? S Driver for LabVIEW Version 1.0.2 Release Date: June 1, 2006Driver 066130500 BERTScope Software Release V 10.11.1006
BERTScope(R) Analyzers are designed for applications from 500 Mb/s to 26 Gb/s. They are the industry's first multi-Gb/s instruments that combine the eye diagram analysis capabilities of high-bandwidth sampling oscilloscopes together with BER pattern …Firmware 066123802 Bertscope SATA Support files V1.0
The compressed file has the BERTScope User patterns and JTOL files for the Bertscope SATA application.Waveform 066124800 Bertscope PCI Express Support Files V 1.0
The compressed file has BERTScope User patterns, Mask Files and Jitter Tolerance files for the Bertscope PCI Express Application.Waveform 066124600 Bertscope SAS Support files V1.0
The compressed file has the BERTScope User patterns and Jitter Tolerance files for the Bertscope SAS application.Application 066124900 Bertscope Software Support - Jitter Tolerance Template files V1.0
BERTScope Template files to be used with the Jitter Tolerance applications.Waveform 066125000 Bertscope USB 3.0 Support files V1.0
The compressed file has the User patterns, Mask, JTOL and Configuration files for the Bertscope USB 3.0 application.Waveform 066124700
-
FAQS FAQ ID I have lost or damaged one of the front panel signal connectors on my Tektronix BERT scope. How do I obtain a replacement connector?
A replacement connector is Tektronix p/n 131906200. These connectors are designed to be easily replaceable as they unscrew from the permant front panel input connector. When damaged, you remove the damaged connector and replace with a new connector …64646 How do I use TekExpress to perform a USB 3.0 Device Transmitter Test?
USB 3 Tx Testing ScriptHello and welcome to Tektronix! Today I’m going to walk through a USB 3 Device Transmitter Test using TekExpress.A USB 3 Transmitter test consists of acquiring the signal from a USB 3 Device and running it through various tests …69376 I want to know how to view the .ram user pattern files on the BERT scopes. I used to be able to view them but cannot locate the process anymore. I would like to view them in hex format. If I recall correctly, the .RAM format includes repeats for sections of the data, and isn't directly readable.
For viewing of RAM files, use the Editor view. Within the Editor view, press File, Open, Raw RAM Memory File.64856 Can Microsoft Remote Desktop be used with Windows based oscilloscopes?
Yes, the Remote Desktop feature of the Professional Editions of Windows can be used on Tektronix DPO/MSO/CSA Series Oscilloscopes running Windows XP or later operating systems. In order to use the Remote Desktop feature of Windows, you will need to …61606