Contact us
Call us at
Available 6:00 AM – 5:00 PM (PST) Business Days
Download
Download Manuals, Datasheets, Software and more:
Feedback
DPO7000
Bandwidths up to 3.5 GHz and sampling rates up to 40 GS/s make the DPO7000C Series a natural choice for analyzing critical, high-speed signals. Over 30 analysis packages provide in-depth measurements for communications standards, jitter analysis, memory bus standards, vector analysis and more. Plus, the Windows operating system lets you run your own analysis software right on the instruments.
See all oscilloscopes »
New DPO7000 Series oscilloscopes are no longer available for ordering. The 6 Series MSO is the recommended replacement. Please check https://www.tek.com/encore for availability of refurbished instruments.
Up to 3.5 GHz
4
Up to 500
Mpoints
Up to 40 GS/s
Advanced signal measurement and analysis
Standard analysis tools include 53 automated measurements, measurement statistics, histograms, limit testing, advanced waveform math, user-definable filters and support for custom MATLAB and .NET math plug-ins. Specialized applications such as advanced jitter and eye analysis, and wideband RF analysis, can be added to extend the measurement capabilities.
Highlights
- Characterize signal parameters with a suite of standard measurement tools
- Advanced jitter and timing analysis characterizes signal integrity issues and their sources
- SignalVu software provides wideband spectral analysis and measurements, with options for audio, modulation, RF pulses and settling time
- TekScope AnywhereTM software enables offline measurements and analysis
Powerful triggering makes capture easy
Easily capture signal anomalies, including glitches, runts, setup/hold violations and NRZ pattern lock for serial data streams up to 1.25 Gb/s, with Pinpoint® triggering and Visual Trigger and Search.
Highlights
- More than 1,400 available trigger combinations
- Quickly define complex triggers and search criteria graphically with Visual Trigger
- Optional serial triggers provide protocol-aware signal capture capabilities
Serial analysis and compliance testing, done right
Simplify advanced system design debug and verification with protocol decode and serial trigger options for low- and mid-speed buses. Ensure interoperability of mid-speed serial buses with automated compliance testing.
Highlights
- Protocol decode with serial triggering and analysis options available for I2C, SPI, RS-232/422/485/UART, USB 2.0, Ethernet, MIL-STD-1553B, CAN, LIN, and FlexRay
- Automated compliance testing packages available for USB 2.0, Ethernet, HSIC, MOST, and BroadR-Reach
Automated power measurements
Automated measurements and reporting ensure simple, repeatable power quality, switching loss, magnetic loss, harmonics measurements and more meet the measurement demands of today’s efficient power converters. Plus, smart TekVPI current and differential probes reduce uncertainty and eliminate power measurement pitfalls.
Highlights
- MOSFET switching loss and safe operating area analysis
- Power factor and harmonics measurements for IEC61000-3-2 pre-compliance
- In-circuit inductor and transformer loss measurements
- USB power adapter compliance testing to USB2.0 Battery Charger Specification v1.1 and IEC 62684
Tektronix DPO7000C |
Tektronix MSO/DPO5000B |
Keysight S Series |
LeCroy HDO6000 |
|
Bandwidth | 500 MHz to 3.5 GHz | 350 MHz to 2 GHz | 500 MHz to 8 GHz | 350 MHz to 1 GHz |
Analog Channels | 4 | 4 | 4 | 4 |
Analog Sample Rate (All Channels) | Up to 10 GS/s | Up to 5 GS/s | Up to 10 GS/s | Up to 2.5 GS/s |
Analog Sample Rate (1 Channel) | Up to 40 GS/s | Up to 10 GS/s | Up to 20 GS/s | Up to 2.5 GS/s |
Maximum Optional Record Length (1 Channel) | 500 M | 250 M | 100 M | 250 M |
Waveform Capture Rate (wfms/s) | >310,000 | >250,000 | Not Specified | Not Specified |
Operating System | Windows | Windows | Windows | Windows |
Automated power measurements
Automated measurements and reporting ensure simple, repeatable power quality, switching loss, magnetic loss, harmonics measurements and more to meet the measurement demands of today’s efficient power converters. Plus, smart TekVPI current and differential probes reduce uncertainty and eliminate power measurement pitfalls.
Highlights
- Opt. PWR: Advanced power measurement and analysis solution for characterization and testing of power devices and power supplies including power quality and harmonic testing
- Opt. USBPWR: Automated compliance testing for USB power adapters to USB2.0 Battery Charger Specification v1.1 and IEC 62684
Automotive serial analysis and compliance testing
Simplify automotive system design debug and verification with protocol decode and serial trigger options for CAN, LIN and FlexRay buses. Ensure interoperability of BroadR-Reach and MOST serial devices with automated compliance testing.
Highlights
- Opt. SR-AUTO: CAN, LIN, and FlexRay protocol trigger and decode of serial packet content
- Opt. BRR: BroadR-Reach/100BASE-T1 and 1000BASE-T1 Automated Compliance Solution
- Opt. MOST: Electrical compliance and debug test solution for MOST50 and MOST150 host and device designs
Embedded serial decoding and analysis
Protocol decode, serial triggering, and analysis for I2C, SPI, RS-232/422/485/UART, USB 2.0, Ethernet, and MIL-STD-1553B simplify advanced system design debug and verification.
Highlights
- Opt. SR-AERO MIL-STD-1553B protocol trigger and decode of serial packet content
- Opt. SR-COMP RS-232/422/485/UART protocol trigger and decode of serial packet content
- Opt. SR-DPHY MIPI® D-PHY automatic decode and search on serial packet content
- Opt. SR-EMBD I2C and SPI protocol trigger and decode of serial packet content
- Opt. SR-ENET 10BASE-T and 100BASE-TX protocol search and decode of serial packet content
- Opt. SR-USB USB 2.0 low-speed, full-speed and high speed protocol trigger and decode of serial packet content
Serial compliance testing
Ensure interoperability of USB 2.0 and Ethernet serial designs with automated compliance testing.
Highlights
- Opt. ET3 Automated characterization, compliance and full PHY layer support for 10BASE-T, 100BASE-TX and 1000BASE-T
- Opt. USB2 Perform "one touch" compliance testing with automated instrument and test mode control
- Opt. HSIC Electrical signal quality test and protocol validation of HSIC host and device designs
- Opt. DDRA Complete memory interface analysis package for DDR1/2/3/4, LPDDR1/2/3/4 and GDDR3/5
Advanced jitter and timing analysis
With comprehensive jitter and eye-diagram analysis, plus decomposition algorithms, DPOJET simplifies discovering signal integrity concerns and jitter and their related sources in today's high-speed serial, digital and communication system designs.
Highlights
- Characterize performance of high-speed serial and parallel bus designs
- Characterize clock and data jitter/noise and signal integrity
- Characterize modulation of spread spectrum clock circuits
- Perform PHY testing of serial standards such as MIPI® D-PHY, DDR and MOST
Wideband RF analysis
SignalVu RF and vector signal analysis software provides the functionality of a vector signal analyzer and spectrum analyzer, with the powerful trigger capabilities of a digital oscilloscope—all in a single package. Use SignalVu to easily validate wideband designs and characterize wideband spectral events.
Highlights
- Opt. SVE: SignalVu Essentials provides wideband spectral analysis and measurements
- Opt. SVA: SignalVu AM/FM/Direct audio measurements
- Opt. SVM: SignalVu general-purpose modulation analysis
- Opt. SVP: SignalVu advanced pulse signal analysis
- Opt. SVT: SignalVu settling time measurements–frequency and phase
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | TCP0020 | Probe, AC/DC Current; 20 Amp; 50 MHz BW; TekVPI Interface; Certificate of Traceable Calibration Standard | Configure & Quote |
View Datasheet | TCP0030A | Probe, AC/DC Current; 30 Amp DC, DC TO 120 MHZ; with TekVPI Interface; Certificate of Traceable Calibration Standard | Configure & Quote |
View Datasheet | TCP0150 | Current Probe: 20 MHz, 5 mA to 212 A, AC/DC, TekVPI | Configure & Quote |
View Datasheet | TCP202A | Probe, AC/DC Current; DC coupled, 15 Amp Max DC; 50 MHz BW, TekProbe Lvl2 Interface; Certificate of Traceable Calibration Standard | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | TDP0500 | Differential Probe: 500 MHz, 5X/50X, +/- 42V, TekVPI | Configure & Quote |
View Datasheet | TDP1000 | Differential Probe: 1 GHz, 5X/50X, +/- 42V, TekVPI | Configure & Quote |
View Datasheet | THDP0100 | Differential PROBE; 100 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE | Configure & Quote |
View Datasheet | THDP0200 | Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE | Configure & Quote |
View Datasheet | TMDP0200 | Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL MEDIUM VOLTAGE PROBE;TMPD0200 | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | P5100A | High Voltage Probe: 500 MHz, 100X, 2.5 kV, Single-ended, BNC | Configure & Quote |
View Datasheet | P6015A | PROBE HIVOLTAGE; 75MHZ,40KV,1000X 10 FT - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | P6247 | PROBE,DIFF,ACT; 1GHZ BW,+/- 0.85/8.5V,1PF,TPI - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote |
View Datasheet | P6248 | PROBE; 1.7GHZ DIFFERENTIAL - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote |
View Datasheet | TDP1500 | Differential Probe: 1.5 GHz, 1X/10X, +/-8.5V, TekVPI | Configure & Quote |
View Datasheet | TDP3500 | Differential Probe: 3.5 GHz, 5X, +/- 2V, TekVPI | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | P6243 | Active Probe: 1 GHz, 10X, Single-ended, TekProbe | Configure & Quote |
View Datasheet | P6245 | PROBE,FET ACT; >1.5GHZ,10X,<1PF,TDS SERIES - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD | Configure & Quote |
View Datasheet | TAP1500 | Active Probe: 1.5 GHz, 10X, Single-ended, TekVPI | Configure & Quote |
View Datasheet | TAP1500L | Configure & Quote | |
View Datasheet | TAP2500 | Active Probe: 2.5 GHz, 10X, Single-ended, TekVPI | Configure & Quote |
View Datasheet | TAP3500 | Active Probe: 3.5 GHz, 10X, Single-ended, TekVPI | Configure & Quote |
Datasheet Link | Probe | Description | Configure and Quote |
---|---|---|---|
View Datasheet | P6101B | Probe, Passive; 15 MHz, 1X | Configure & Quote |
View Datasheet | P6139B | Passive Probe: 500 MHz, 10X, BNC | Configure & Quote |