Contact us
Live Chat with Tek representatives. Available 6:00 AM - 4:30 PM
Call us at
Available 6:00 AM – 5:00 PM (PST) Business Days
Download
Download Manuals, Datasheets, Software and more:
Feedback
Datasheets, Manuals, and Software Downloads
While we’re happy to “talk tech” with you all day long, we know you’re in a hurry.
So we’ve made it easy for you to download product manuals, datasheets and downloadable software which includes firmware, drivers, etc. for all our current products, and many discontinued products as well. Just tell us which product you’re using, and we’ll provide you with list of latest documents and resources that you can download.
The product model you have chosen is currently available for purchase. The following support information is available.
-
Datasheet Literature Number: ReleaseDate Spectrum Analyzer
The RSA600A Series USB spectrum analyzers offer high bandwidth laboratory spectrum analysis in a small, very transportable package.37W-60397-13
-
Manuals Manual Type Part Number: ReleaseDate SignalVu-PC Vector Signal Analysis Software Help
Vector Signal Analysis Software for PCUser Manuals 077072021 SignalVu-PC Vector Signal Analysis Software Help
Vector Signal Analysis Software for PCUser Manuals 077072021 SignalVu-PC Vector Signal Analysis Software Programmer Manual
Vector Signal Analysis SoftwareProgrammer Manuals 077072120 SignalVu-PC Vector Signal Analysis Software Programmer Manual
Vector Signal Analysis SoftwareProgrammer Manuals 077072120 RSA603A and RSA607A
Real-Time Spectrum Analyzers Installation and SafetyPrimary User 071346001 RSA500A and RSA600A Series Specifications and Performance Verification Manual
Real-Time Spectrum AnalyzersSpecifications and Performance VerificationPerformance Verification 077120102 SignalVu-PC
Vector Signal Analysis SoftwareHelp Files 077072015 RSA306, RSA306B, and RSA500A/600A Programmer Manual
Spectrum Analyzer Application Programming Interface (API)Programmer Manuals 077103105 RSA500A and RSA600A Series
Real-Time Spectrum AnalyzersDeclassification and SecurityDeclassification Manuals 077120201 RSA5600RACK Rackmount Kit Instructions
Rackmount Kit InstallationField Install Instructions 071346801 RSA Map Help
Mapping SoftwareHelp Files 077075802 RSA306, RSA306B, and RSA500A/600A
Spectrum Analyzer Application Programming Interface (API)Programmer Manuals 077103104 RTSA V3 Demo Board Quick Reference Card
Quick Reference CardUser Manuals 071332901
-
Technical Documents Document Type ReleaseDate advanced radar analysis tools measuring modern radar application note
LƯU Ý ỨNG DỤNG Optimizing Frequency Settling Time Measurements
Frequency settling time is an essential measurement in the design and evaluation of RF synthesizers, programmable oscillators, phase locked loop circuits, and more. This technical brief highlights the steps taken to reduce the noise/variation on a …Tóm tắt kỹ thuật Overcoming 3 Key Challenges of Time- and Frequency-Correlated RF Measurements
Tektronix Real-Time Spectrum Analyzers (RTSAs) capture and store signals as a seamless, continuous record of time. Combining deep memory with powerful digital signal processing, RTSAs allow for a variety of triggering, display, and analysis …Tờ số liệu Re-Imagine 5G Measurements
SignalVu Vector Signal Analysis Software offers a broad range of RF measurements and is available for both Tektronix spectrum analyzers and oscilloscopes, including the 6 Series B MSO and DPO70000SX Series oscilloscopes. The …Sách quảng cáo Solutions for RADAR and Electronic Warfare
PRODUCTS FOR THE ENTIRE SYSTEM DEVELOPMENT LIFECYCLE Tektronix offers a wide range of hardware and software built to help you design and test mission-critical RF systems, such as military comms, radar and electronic warfare—from …Sách quảng cáo Spectrum Monitoring Moves to the Edge with Intel NUC Mini PCs
This case study explores the potential of combining Tektronix USB-based signal analyzers and Intel® NUC Mini PCs for a fast, cost-effective spectrum monitoring solution. Drone detection is just one of many applications for Tektronix’s USB-based Real …NGHIÊN CỨU ĐIỂN HÌNH eGuide to RF Signals
A GUIDE TO THE RADIO SPECTRUM UNLICENSED/ISM BANDS CELLULAR RADIO AND TELEVISION BROADCAST LAND MOBILE RADIO AERONAUTICAL COMMUNICATIONS WEATHER RADAR WHAT’S A SPECTRUM DISPLAY? Additional …Sách hướng dẫn Power Supply Converter Design Procedures
This poster offers insight into power supply converter design procedures, test stages, challenges, and solutions.Áp phích Tire Pressure Monitoring Systems and Remote/Passive Keyless Entry
Today, more sophisticated and sensitive RF electronic components and devices are being included in automobiles. These advances have resulted in much safer, efficient, and connected vehicles. They have also created new challenges for RF testing and …LƯU Ý ỨNG DỤNG Programmatic Control on Tektronix USB Real Time Spectrum Analyzers
Introduction Using the latest in commercial interfaces and available computing power, the Tektronix RSA 300/500/600 USB real time spectrum analyzers separate signal acquisition from measurement, dramatically lowering the cost of …LƯU Ý ỨNG DỤNG Low Cost, High Speed Spectrum Analyzers For RF Manufacturing
LƯU Ý ỨNG DỤNG Low Cost RF Sensors
Introduction Radio monitoring systems have historically been operated by government and military organization who need to have situational awareness of the radio spectrum. These large systems were expensive and required significant …LƯU Ý ỨNG DỤNG Understanding Radar Signals Using Real-Time Spectrum Analyzers
The transient nature of radar pulses combined with modern pulse compression schemes often demand carefully designed test setups. This Primer will cover measurements methods, choosing your measurement parameters, how to find the pulse, estimating the …Sách hướng dẫn Real-Time Spectrum Analysis for EMI Diagnostics
Introduction From the first wireless transmissions, electromagnetic interference (EMI) has been a concern for design engineers. The earliest spark-gap transmitters had no facility for spectrum control, and the presence of two …LƯU Ý ỨNG DỤNG Low-cost EMI Pre-compliance Testing Using a Spectrum Analyzer
EMI regulations are in place throughout the world to provide improved reliability and safety for users of electrical and electronic equipment. To ensure compliance with these regulations, many companies employ the services …LƯU Ý ỨNG DỤNG 6 Key Challenges of the Internet of Things
Introduction The Internet of Things (IoT) promises to change the world by connecting devices in larger, more interoperable systems controlled by software and analytics. The proliferation of device, software, and analytics …Sách hướng dẫn DPX Acquisition Technology for Spectrum Analyzers Fundamentals
A Revolutionary Tool for Signal Discovery, Trigger, Capture and Analysis Detection is the first step in characterizing, diagnosing, understanding and resolving any problem relating to timevariant signals. As more …Sách hướng dẫn Cable and Antenna Measurements Using Tektronix USB Spectrum Analyzers
This application note looks at the basics of line sweeping measurements on cable and antenna systems, including a look at why they are important and how to perform them.LƯU Ý ỨNG DỤNG Speeding Through Wireless Standards
This Tutorial is designed to help you decide what to include in your test plan so that you ensure the product will pass regulatory certification and standard qualification. This guide will explain why pre-compliance testing for the wireless standard …Sách hướng dẫn Spectrum Pre-compliance for Wireless LAN Regulatory Testing
The most common way to add wireless capability is to use a prepackaged WLAN module. While this approach greatly simplifies the process, it still has many challenges. This application note outlines the typical design cycle and potential pitfalls you …LƯU Ý ỨNG DỤNG RF Recording and Playback Solutions
Introduction to RF Record and Playback Spectrum management, RF interference analysis, signal acquisition, product testing and validation, RF system design, communication security, and academic research, all routinely perform or can benefit from the …LƯU Ý ỨNG DỤNG
-
Software Document Type Part Number: ReleaseDate SignalVu-PC Vector Signal Analysis Software - V5.3.0043
This version introduces enhancements for multi-channel analysis using 5 or 6 Series MSO oscilloscopes, including ability to measure phase difference between channels, organize displays by source or measurement, and view each channel as a different …Application 066143445 SignalVu-PC Vector Signal Analysis Software - V4.5.0093
SignalVu-PC software V4.5.0093 brings the full vector signal analysis (VSA) engine of the Tektronix Real-Time Signal Analyzer (RTSA) to your computer, tablet, or Windows embedded oscilloscope, enabling you to analyze live signals, as well as perform …Application 066143429 SignalVu-PC Vector Signal Analysis Software - V4.1.0022
SignalVu-PC VSA software brings the analysis engine of the Tektronix Real-Time Signal Analyzer (RTSA) to your computer, enabling you to analyze live signals from RSA306, RSA500, RSA600, RSA7100A\B Spectrum Analyzers, MSO54, MSO56, MSO58, MSO64 …Application 066143424 RSA Application Programming Interface – API for 64-Bit Linux – V1.0.0014
The RSA API is a Linux C/C++ Shared Objects that provides direct access to RSA300/500/600 devices. It enables full control of the RSA and provides several forms of data and measurements to support custom applications independent of SignalVu-PC …Application 066207701 RSA Application Programming Interface – API for 64-Bit Linux – CANDIDATE V0.13.220.16
The RSA API is a Linux C/C++ Shared Objects that provides direct access to RSA300/500/600 devices. It enables full control of the RSA and provides several forms of data and measurements to support custom applications independent of SignalVu-PC …Application 066207700 RSA Application Programming Interface - API for 64-Bit Windows - V3.23.0022
This release adds support for the RSA513A and 518A models. The RSA API is a Windows C/C++ DLL that provides direct access to RSA300/500/600 devices. It enables full control of the RSA and provides several forms of data and measurements to support …Application 066169110 RSA Application Programming Interface - API for 32-Bit Windows - V3.23.0022
This release adds support for the RSA513A and 518A models. The RSA API is a Windows C/C++ DLL that provides direct access to RSA300/500/600 devices. It enables full control of the RSA and provides several forms of data and measurements to support …Application 066176207 DataVu-PC Recorded Signal Analysis Software - V1.2.26
DataVu-PC analysis software for recordings makes short work of searching through large datasets for signals of interest. You can measure pulses and mark signals for export to other analysis programs, reducing time spent in post-capture analysis …066190103
-
FAQS FAQ ID After installing SignalVu-PC I encounter the following error. SignalVu-PC Error 1722. There is a problem with this Windows Installer package. A program run as part of the setup did not finish as expected. Contact your support personnel or package vendor. Action RegisterSidewinder, location: C:\Program Files\Tektronix\SignalVu-PC\, command: "C:\Program Files\Tektronix\SignalVu-PC\SignalVu-PC.exe" /register
There can be several reasons for the 1722 error. The most common are: 1. In Dot Net 4.5 or greater installed? If not try installing Dot Net 4.5 or higher. 2. If you have Dot Net 4.5 or greater try repairing Dot Net Framework 4.5 on Windows …72236 The Green LED on my RSAXXX is on, but I cannot connect to SignalVu-PC?
After installation of SignalVu-PC and the Tektronix USB driver, I cannot get the instrument to be found with SignalVu-PC. Note: The first time connecting to the instrument may require up to 30 seconds for SignalVu-PC to find the instrument …251141 What PC should I get to work with the RSA306?
Any PC that meets the performance requirements should work. Tektronix doesn’t make a specific recommendation, but a list of models we’ve evaluated is shown below. In one case, we’ve found an Intel core i5-based tablet (Surface 3 Pro) that does meet …69416 What are the PC hardware requirements to run the RSA306 with SignalVu-PC or the API?
A PC with Windows 7, Windows 8/ 8.1, Windows 10 64-bit operating system and a USB 3.0 connection is required for operation of the RSA306. 8 GB RAM and 20 GB free drive space is required for installation of SignalVu-PC. For full performance of the …69411 What is the part number for the RSA306/306B, RSA503A/507A, RSA603A/607A demo kit?
Part number for the demo kit is RSA-DKIT The demo manual can be found here: https://www.tek.com/spectrum-analyzer/rsa306-usb-manual-272176 What is the maximum RF bandwidth supported by the Real Time Spectrum Analysis products?
The RSA306B has a maximum bandwidth of 6.2 GHz. The RSA500 has a maximum bandwidth of 18 GHz. The RSA600 has a maximum bandwidth of 7.5 GHz. The RSA7100B has a maximum bandwidth of 26.5 GHz. See the Spectrum Analyzers page for the …64186 Can I communicate with multiple USB RSAs Simultaneously?
Yes there are two options to communicate with multiple RSA's: Two USB RSA's can be controlled through the software DataVu-PC. DataVu-PC offers recording using two RSAs so that you can operate at two independent frequencies and spans simultaneously …773771 Can I connect to two USB RSA's at the same time?
Using DataVu-PC you can indeed connect to two RSA500A, RSA600A, or RSA306B’s concurrently. Both SA’s need USB3.0 connections and adequate throughput, then you can select RSA LiveVu 1 and 2. Trial licenses for DataVu-PC functionality can be found …474111 When using SignalVu-PC how do I find my system's Host ID?
To find the Host Id while using SignalVu-PC select Tools > Licenses > Manage. This will open the Manage Licenses window. Under the Select license host window on the left choose the system that you wish to view the Host ID. <> refers … 474071 As a Windows C/C++ DLL, the RSA API can be used in many C/C++ development environments including National Instruments LabWindows/CVI. However, due to the way LabWindows/CVI 2010 handles the loading of external .DLLs, the compiled executable will experience a fatal run-time error. When this occurs you will receive a message like the following:FATAL RUN-TIME ERRORUnknown source position, thread id 0x0000XXXXA non-debuggable thread caused a ‘General Protection’ fault at address 0xXXXXXXXX.Please note: this issue has been confirmed to exist in LabWindows/CVI 2010 and may exist in other versions of LabWindows/CVI as well. LabWindows/CVI 2015 has shown not to exhibit this problem.
National Instrument has confirmed this issue with other external libraries and has written up a KnowledgeBase article showing how to fix the issue. You can read this article at the following URL.http://digital.ni.com/public …72206 How do I tell if my RSAxxx has successfully connecting to my computer?
Watch the USB status LED when you first plug in the USB cable. See actions below: Note: When you first connect the USB cable to a PC USB 3 port (for the first time) this light may be red for up to up to maybe one minute as the USB driver is installed …251136 Can I record data from two USB RSA’s at the same time?
Yes recording of streaming data is possible up to 40MHz bandwidth for either free running or triggered data, using DataVu-PC with the RSA500A, RSA600A, or RSA306B’s. Playback Information – The FFT time, sample time resolution, resolution bandwidth …474116