Features & Benefits
- True RMS Multimeter
- Basic and Advanced Oscilloscope Functions: Measure signals up to 5 MHz
- Dual-Channel Scope Capability
- Work with standard DMM accessories
Applications
- Relative Timing Measurements
- Power Measurements
Characteristics
Multimeter Capabilities
Resolution - 4000 count, 3364 digits
DC Voltage Ranges - 400.0 mV to 850 V
DC Volts Accuracy - ±(0.5% of reading + 5 counts)
True RMS AC Voltage Ranges - 400.0 mV to 600 V
AC Volts Accuracy -
50 to 60 Hz: ±(2% of reading + 5 counts)
500 Hz: ±(3% of reading + 5 counts)
Resistance Ranges - 400.0 ohm to 40.00 Megohm
Resistance Accuracy - ±(0.5% of reading + 2 counts); 40 Megohm ±(2% of reading + 5 counts)
Diode Test Range - 0 to 2 V
Continuity Check - Audible/visible indicators
Modes - Min, Max, Max-Min, Hold, Delta Hold
Oscilloscope Capabilities
Digitizers, Channels - Two
Maximum Sample Rate - 25 MS/s per channel
Bandwidth - DC to 5 MHz
Vertical Sensitivity - 5 mV to 500 V/div
Peak Detect - 40 ns
Record Length - 256 points
Reference Waveforms - 4 waveforms
Setup Storage - 4
Reference Screens - 1
Acquisition Modes - Sample, Spike Detect, Smooth, Roll, Dynamic Display DSP
Trigger Modes - Auto-Level, Auto, Normal, Single Shot
Operation Modes - Autorange, Manual, Single Shot, AC-Line Test
Cursors w/ Readouts - Delta V, Delta T, 1/Delta T
Measurements - Frequency, Period, Max, Min, Pk-Pk, Duty Cycle, RMS Power Factor, THDF
Waveform Math - Add, Subtract
Display Update Rate - Up to 500 waveforms/second
Physical Characteristics
Length: 211 mm (8.3 in.)
Width: 141 mm (5.6 in.)
Depth: 43 mm (1.7 in.)
Net Weight (including Battery): 1 kg
Operating Ambient Temperature - 0 to 50 °C
Display - 256 × 128 dot LCD
Power Source - 6 AA batteries
Battery Life - 4.5 hr typical (alkaline cells)
Safety
CSA, UL 3111, IEC 1010
EMI - CE rated for emissions