Contact us
Live Chat with Tek representatives. Available 6:00 AM - 4:30 PM
Call us at
Available 6:00 AM – 5:00 PM (PST) Business Days
Download
Download Manuals, Datasheets, Software and more:
Feedback
Features & Benefits
- An Easy-to-use, Plug-on Accessory for Oscilloscopes That Feature the TekVPI Interface
- Generates Source Signals to Enable Precise Deskew Between Current and Voltage Probes in Power Measurement Applications
- LED Status Indicator for Quick Identification of Generator State
- Multiple Output Signals Enable Use with a Variety of Oscilloscopes and Probes
- Output can be Turned Off to Reduce Power Consumption when Not in Use
- Easy Access to Oscilloscope Menu Display to Control Settings from the Oscilloscope Front Panel
Applications
- Power Supply Design
- Measurements Requiring Accurate Timing Measurements Between Channels
TEK-DPG Deskew Pulse Generator
The TEK-DPG Deskew Pulse Generator is a signal-generating accessory for Tektronix instruments that feature the TekVPI™ interface, including DPO3000 Series and DPO/MSO4000 Series oscilloscopes.
The TEK-DPG generator provides a source signal to the Power Measurement Deskew Fixture (Tektronix part number 067-1686-xx), used to deskew popular Tektronix probes. The generator and deskew fixture allow you to precisely deskew the time differences between instrument channels of current and voltage probes, necessary when you are using the probes in power measurement applications.
Characteristics
Mode | Amplitude | Frequency | Rise Time |
---|---|---|---|
(all values are Typical) | |||
Mode 1 | 1 Vp-p (-1 V..0 V) | 1 kHz | 0.8 ns |
Mode 2 | 2 Vp-p (-2 V..0 V) | 1 kHz | 1.6 ns |
Mode 3 | 2 Vp-p (-1 V..+1 V) | 1 MHz | 2 ns |
Mode 4 | 8 Vp-p (-4 V..+4 V) | 1 MHz | 4 ns |
Terminates Into - 50 Ω
Expected Load - 50 Ω
Status LED Values
Status LED Color | Description |
---|---|
Amber | The generator is powered and the output at the BNC cable is not enabled. This is the default status at power-on |
Green | The generator is powered and the output at the BNC cable is enabled |
Red | A fault condition may have occurred. Disconnect and reconnect the generator to clear the fault condition |
Recommended Output Mode
Probe*1 | Operation | TEK-DPG Output Mode*2 | 067-1686-xx Input Port |
---|---|---|---|
The recommended output mode is determined by the combination of oscilloscope model, voltage probe, and current probe, according to the following table. See the user instructions for the Power Measurement Deskew Fixture, Tektronix part number 067-1686-xx, for deskew fixture operation. | |||
Passive Voltage Probes | |||
P6139A, P5050, and Other 10x Passive Probes | Compensate timing with respect to current probes | DPO3000: Mode 2 DPO/MSO4000: Mode 1 | A or B, depending on current probe type |
Active Voltage Probes | |||
TAP1500, TAP2500, TAP3500 TDP0500, TDP1000, TDP1500 P6243, P6245, P6246, P6247, P6248, P6250, P6251 | Compensate timing with respect to current probes | DPO3000: Mode 2 DPO/MSO4000: Mode 1 | A or B, depending on current probe type |
High-voltage Probes | |||
P5200, P5205, P5210 P6135A | Compensate timing with respect to current probes | DPO3000: Mode 2 or 4*3 DPO/MSO4000 : Mode 1 or 4*3 | A or B, depending on current probe type |
Small Current Probes | |||
TCP0030 TCP202, TCP312, TCP305 A6302, A6312 | Compensate timing with respect to voltage probes | DPO3000: Mode 2 or 4*3 DPO/MSO4000: Mode 1 or 4*3 | A |
Large Current Probes | |||
TCP0150 TCP303 A6303 | Compensate timing with respect to voltage probes | DPO3000: Mode 4 DPO/MSO4000: Mode 4 | B |
*1 Note that some probe models listed do not utilize the TekVPI interface. Probes which use the TekProbe-BNC interface require the TPA-BNC adapter to connect to a TekVPI oscilloscope.
*2 TEK-DPG is not supported by the DPO7000 Series. The Probe Calibration output from the DPO7000 Series generates the appropriate source signal for the Power Measurement Deskew Fixture.
*3 Mode 4 is a universal mode for high attenuation probes. High-voltage probes and current probes can always use Mode 4.
Physical Characteristics
Dimensions | cm | in. |
---|---|---|
Height | 3.048 | 1.20 |
Width | 4.064 | 1.60 |
Length | 11.73 | 4.62 |
Cable Length | 41.225 | 16.2 |
Weight | kg | lb. |
Shipping | 0.325 | 0.7175 |
Power Requirements
- TEK-DPG is powered directly from DPO3000, DPO/MSO4000, and DPO7000 Series Oscilloscopes, using the TekVPI probe interface.
Environmental
Characteristic | Description |
---|---|
Temperature | |
Operating | 0 °C to +50 °C |
Nonoperating | -40 °C to +71 °C |
Humidity | |
Operating | 5% to 90% relative humidity (% RH) at up to +40 °C 5% to 60% RH above +40 °C up to +50 °C, noncondensing |
Nonoperating | 5% to 90% RH (relative humidity) at up to +40 °C 5% to 60% RH above +40 °C up to +50 °C, noncondensing |
Altitude | |
Operating | Up to 3000 meters (9,843 feet) |
Nonoperating | Up to 12,000 meters (39,370 feet) |
Regulatory | |
Emissions Compliance | EN 55011, Class A |
EMC Compliance | EN61326, Class A |
Compliance Labeling | WEEE (European Union) |
Standard Warranty
One-year parts and labor.
Recommended Oscilloscopes
- DPO3000 and DPO/MSO4000 Series Oscilloscopes with TekVPI probe interface.
- TEK-DPG is not supported by the DPO7000 Series Oscilloscopes, as these models provide the appropriate source signal at the Probe Calibration output on the front-panel BNC connector.
Ordering Information
TEK-DPG
TEK-DPG Deskew Pulse Generator Signal Source
Includes: User manual (071-2341-xx).
Recommended Accessories
Tektronix Power Deskew/Calibration Fixture - (067-1686-xx).
Service Options
Option | Description |
---|---|
R3 | Repair Service 3 Years |
R5 | Repair Service 5 Years |
SILV600 | Standard Warranty Extended to 5 Years |
Additional Service Products Available During Warranty (DW)or Post Warranty (PW) | |
TEK-DPG-R1PW | Repair service coverage 1-year post warranty |
TEK-DPG-R2PW | Repair service coverage 2-year post warranty |
TEK-DPG-R3DW | Repair service coverage 3 years (includes product warranty period). 3-year period starts at time of customer instrument purchase |
TEK-DPG-R5DW | Repair service coverage 5 years (includes product warranty period). 5-year period starts at time of customer instrument purchase |