Improving Performance of Power Management Devices

Diverse, custom applications can be engineered using power management devices, including power management ICs, power management units, battery management units, and DC-DC converters, used in application including EVs, smart homes and devices, motor controls, power-loss protection devices, and more. Design Engineers continue to investigate how their devices can improve power efficiency over wide voltages and environmental operating conditions.

Accelerating Power Management Device Testing

Test PMICs and PMUs

PMIC/PMU is the key battery management component in battery-powered devices.


Learn More:

How to Accelerate a Power Management Unit Test

Test PMICs and PMUs

Designing and evaluating the power management IC (PMIC) or power management unit (PMU) are very important steps in the product development process. The PMIC/PMU is the module in an electronic device that manages the battery. Assessing a PMIC/PMU is essential to ensure that the product works correctly when the battery is in different states of charge, various amp-hour capacity levels, and at different battery impedances, and to ensure that its charge/discharge function works properly and will not damage the battery by over-charging or over-discharging.

Ensure The Highest Power Integrity

Characterizing PMICs, PMUs, and battery management units (BMU) for power integrity, power efficiency, signal integrity, common mode noise, and multi-rail management ensures that devices operate as designed and are well optimized. Tek’s power integrity analysis solution, enabled by either the 5 or 6 Series B MSO, includes probes and analysis tools you need to accelerate time to validation.

  • Validate power supply sequencing
  • Find sources of power rail ripple
  • Correlate voltage, current and digital signals
Tektronix 6 Series B 5 Series B Ensure Highest Power Integrity

Software tools for oscilloscopes accelerated power integrity validation.


Learn More:

Power Integrity Analysis Reference Solution

Getting Started with Power Rail Measurements

Validating Power Rail Performance

Leverage the capabilities of Power Rail probes to analyze additional high frequency noise overlaid on the ripple.


Learn More:

Measuring Ripple and Noise on Power Rails

 

Validating Power Rail Performance

Power integrity, signal integrity analysis, power rail and ripple measurements play a critical role especially with highly integrated system on chip and microprocessor designs in which multiple technologies interface together. It is important to look at each DC line to see if the power supplied is within the tolerance band of a target system or device. The typical applications can be found across industries that need power conversion and have multiple DC voltage levels in the circuit design.

Test DC-DC Converters

Given the increased pressure to develop products that consume less power and have longer battery life, design engineers need to achieve higher power conversion efficiencies. As a result, numerous measurements are required to characterize the electrical parameters of DC- DC converters. The tests performed include line regulation, load regulation, input and output voltage accuracy, quiescent current, efficiency, turn-on time, ripple, and transient response. Some of these tests require DC test instruments for sourcing and measuring; others require an oscilloscope, and some may require both.

Test DC-DC Converters

Testing a non-isolated DC-DC converter using both a scope and two SMUs.


Learn More:

Simplifying DC-DC Converter Characterization

Products

5 series B MSO - MSO58B

Осциллограф смешанных сигналов Серии 5 B MSO

MSO Серии 5 — это осциллограф смешанных сигналов с сенсорным дисплеем высокого разрешения, числом входов до 8, 12-битными аналого-цифровыми преобразователями и полосой пропускания до 2 ГГц.

6 Series B MSO Mixed Signal oscilloscope

Осциллограф смешанных сигналов MSO Серии 6 B

Прибор с широкой полосой пропускания — от 1 ГГц до 10 ГГц — может обеспечить диагностику и проверку высокоскоростных устройств.

2602B Front

SMU 2600B: одно- или двухканальные системы

  • Испытания полупроводниковых устройств
  • Разработка полупроводниковых приборов
  • Определение характеристик транзисторов
  • Тестирование токов, потребляемых в состоянии покоя или режиме ожидания
  • Испытания многовыводных устройств
Series 2280 Precision Measurement Variable Bench Power Supply

Прецизионные источники питания постоянного тока серии 2280

  • 192 Вт при токе до 6 А
  • Разрешение измерений тока: разрядность 6 ½, 10 нА
  • Отображение графиков изменения напряжения и тока
Power rail probes

Пробники шин питания

Пробники шин питания отличаются низким шумом, низкой входной ёмкостью, широкой полосой пропускания и высоким смещением по постоянному току, которые так важны при измерениях целостности сигналов питания.

High voltage differential probes

Высоковольтные дифференциальные пробники

Лучшие в отрасли характеристики — до 6 000 В. С сертификатом безопасности

Resources

Брошюра

Application Software Bundles for the 4, 5 and 6 Series MSO Oscilloscopes

Learn about the application software bundles that are available for the 4, 5 and 6 Series MSOs.  Application bundles are …
Product Demo

Measuring Ripple and Noise on Power Rails

Learn how spectrum analysis on a 5 Series B MSO, along with voltage-vs-time waveforms, provides more insight into power …
How-To

Making Power Rail Measurements

See the ultra-low noise performance of the TPR4000 Power Rail Probe, and how it can be used for measuring DC power rail …
Примечание по применению

Getting Started with Power Rail Measurements Application Note

Power integrity measurements require ripple measurements in the GHz range with very low noise contribution and low …
Примечание по применению

Using Mixed Signal Oscilloscopes to Find and Diagnose Jitter Caused by Power Integrity …

Learn about the connection between signal integrity on data and clock lines, and power integrity.  Includes a review of …