Current Language
×
German (Germany)

Wählen Sie eine Sprache aus:

Menü umschalten
Current Language
×
German (Germany)

Wählen Sie eine Sprache aus:

Kontaktaufnahme

Live-Chat mit Tektronix-Vertretern. Verfügbar von 9 bis 17 Uhr CET Geschäftstage.

Anrufen

Kontaktieren Sie uns telefonisch unter

Verfügbar von 9 bis 17 Uhr CET Geschäftstage.

Download

Laden Sie Handbücher, Datenblätter, Software und vieles mehr herunter:

DOWNLOADTYP
MODELL ODER SCHLÜSSELWORT

Feedback

Next-Generation Oscilloscopes Brochure - 3 Series MDO, 4 Series B MSO, 5 Series B MSO, 6 Series B MSO

Tektronix Oscilloscopes

2001 SPECIFIED CALIBRATION INTERVALS

1) User interface designed for both touch and mouse

2) Large touchscreen HD displays (1,920 × 1,080)

3) Integrated spectrum analysis

4) Powerful analysis

  • Automated measurements with trend, histogram, and spectrum plots
  • Advanced jitter analysis
  • Single-phase and 3-phase power measurement options
  • User-defined filter creation

5) Bandwidth

  • Models from 100 MHz to 10 GHz
  • All models offer upgradeable bandwidth

6) Input channels

  • 2 to 8 inputs depending on model
  • Low-loading probes included for each channel

7) Built in Arbitrary/Function Generator option

8) Record length

  • 10 Mpoints to 1 Gpoints depending on model

9) Up to 12-bit vertical resolution (up to 16 bits in High Res mode)

10) Protocol options

  • 1-Wire
  • 8b10b
  • Automotive Ethernet
  • CAN / CAN FD
  • CXPI
  • eSPI
  • Ethernet
  • EtherCAT
  • eUSB2
  • FlexRay
  • I2C / SPI
  • I2S Audio
  • I3C
  • LIN
  • Manchester
  • MDIO
  • MIL-STD-1533 / ARINC 429
  • MIPI CSI/DSI
  • NFC
  • NRZ
  • PSI5
  • RS-232 / UART
  • SDLC
  • SENT
  • SMBus
  • SpaceWire
  • SPMI
  • SVID
  • USB 2.0

11) Integrated DVM and trigger frequency counter free with product registration

Usability and Display

2001 SPECIFIED CALIBRATION INTERVALS

Touch Interaction Done Right

These next-generation oscilloscopes feature the industry’s first oscilloscope user interface truly designed for touch. The same intuitive gestures you use with your phone or tablet work on the big HD displays and the gestures are common among the 3, 4, 5 and 6 Series.

  • Control inputs, triggers and acquisitions by tapping badges in the settings bar at the bottom of the display
  • Drag waveforms to adjust position or to pan
  • Pinch to change horizontal or vertical scale
2001 SPECIFIED CALIBRATION INTERVALS

Stunning HD Displays

The 15.6" displays on 5 and 6 Series MSOs have 1920 × 1080 HD resolution. You can see many signals at once, along with critical readouts and plots for an extensive view of your system.

Even with their bench-friendly footprints, the 3 and 4 Series offer the largest displays in their classes, with full 1920 × 1080 HD resolution.

2001 SPECIFIED CALIBRATION INTERVALS
Display resolution on some competitors’ products is as low as 800 × 480 pixels. That’s less than 20% of the 1920 × 1080 pixel display resolution of the 3, 4, 5, and 6 Series products. Even larger 1280 × 800 pixel displays do not provide the same level of detail.

Performance and Measurements

More Inputs and Mixed Signal Analysis

The 4, 5 and 6 Series MSOs let you see more signals by going beyond the traditional 4-channel limit, offering up to 8 analog input channels.

FlexChannel™ inputs on the 4, 5, and 6 Series MSOs expand your visibility even further. Whenever you need to see more signals, just plug a TLP058 logic probe into any input. The single analog channel converts to 8 digital channels. FlexChannel inputs are compatible with TekVPI probes.

The 3 Series MDO offers 16 digital channels through a dedicated logic probe, included with the MSO option.

2001 SPECIFIED CALIBRATION INTERVALS

Industry-leading Vertical Resolution

See more signal detail. The 4, 5, and 6 Series MSOs feature 12-bit analog-to-digital converters (ADCs) that provide 16 times more vertical resolution than common 8-bit ADCs.

A new High Res mode further boosts vertical resolution and uses smart filtering to limit noise. High Res mode always provides at least 12 bits and extends all the way to 16 bits of vertical resolution.

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS
8-bit ADCs
2001 SPECIFIED CALIBRATION INTERVALS
12-bit ADCs
2001 SPECIFIED CALIBRATION INTERVALS
12-bit ADCs with High Res turned on

Stacked Display Mode

Most scopes display all waveforms in the same graticule and rely on vertical scale controls to fit signals on the display. Each waveform uses a fraction of the available ADC range, leading to less accurate measurements.

New stacked display mode lets you view each waveform in its own "slice" of the display. Each slice represents the full ADC range for the waveform for more accurate measurements.

The more traditional overlay display mode is also available, for easy direct comparison of waveforms.

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS
New stacked display mode
2001 SPECIFIED CALIBRATION INTERVALS
Traditional overlay display mode

Powerful Measurements

The Results Bar on the right side of the display includes immediate, one-tap access to the most common analytical tools such as:

  • Cursors
  • Automated measurements
  • Measurement statistics
  • Searches
  • Bus decode tables

Gain rich insights with easy access to measurement statistics. Turn on statistics in the Results Bar to get a quick overview.

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

Advanced Measurements and Analysis

Dive into measurements with Results Tables. Results Tables show statistics for the current acquisition and for all acquisitions. Get insight into one measurement, a hundred measurements, or millions of measurements at a glance.

Plots, such as measurement trends and histograms, provide quick visualizations.

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

FastAcq™ High Speed Waveform Capture

FastAcq captures at high speed to increase the probability of seeing infrequent problems such as runt pulses, glitches, timing issues, and more.

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

FastFrame™ Segmented Memory and History Mode

Make the most efficient use of acquisition memory by not storing deadtime between serial packets or bursts. Capture many triggered frames in a single record.

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

Triggering and Search

A complete set of basic and advanced triggers and search criteria.

  • Runt
  • Logic
  • Pulse width
  • Timeout
  • Rise/Fall time
  • Setup and hold violations
  • Serial and parallel bus activity
  • Sequence
  • Video
  • Visual triggers*
  • RF vs Time*
  • Window*

*4, 5, 6 Series only

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

An Oscilloscope for Every Engineer

2001 SPECIFIED CALIBRATION INTERVALS3 SERIES MDO 2001 SPECIFIED CALIBRATION INTERVALS4 SERIES B MSO 2001 SPECIFIED CALIBRATION INTERVALS5 SERIES B MSO 2001 SPECIFIED CALIBRATION INTERVALS6 SERIES B MSO
Bandwidth 100 MHz, 200 MHz,350 MHz, 500 MHz, 1 GHz 200 MHz, 350 MHz,500 MHz, 1 GHz, 1.5 GHz 350 MHz, 500 MHz,1 GHz, 2 GHz 1 GHz, 2.5 GHz, 4 GHz,6 GHz, 8 GHz, 10 GHz
Max channels, analog 4 6 8 8
Max channels, digital 16 48 64 64
Inputs TekVPI inputs FlexChannel inputs FlexChannel inputs FlexChannel inputs
Max sample rate 2.5 GS/s or 5 GS/s, all channels 6.25 GS/s, all channels 6.25 GS/s, all channels 50 GS/s, 2 channels
Record length 10 Mpoints Up to 62.5 Mpoints Up to 500 Mpoints Up to 1 Gpoints
Vertical resolution 8 bits 12 bits 12 bits 12 bits
Advanced analysis(optional) Serial bus, Power Serial bus, Power, 3-Phase Power Serial bus, Power, Compliance, Jitter, Inverters, Motors and Drives Serial bus, Power, Compliance, Jitter, Inverters, Motors and Drives, DDR3, LVDS
Spectrum analysis Hardware Spectrum Analyzer Spectrum View Spectrum View Spectrum View
Operating system Embedded Embedded Embedded
Windows (optional)
Embedded
Windows (optional)
Display 11.6" HD, capacitive touch 1920 × 1080 13.3" HD, capacitive touch 1920 × 1080 15.6" HD, capacitive touch 1920 × 1080 15.6" HD, capacitive touch 1920 × 1080
Starting price $4,510 USD $9,000 USD $19,100 USD $34,700 USD

Pricing shown in US currency and is subject to change. Please check respective product series pages for the most up to date pricing by model.

Integrated Spectrum Analysis

Spectrum View

Because traditional scope FFTs are driven by the same acquisition system that delivers the analog time-domain view, it is virtually impossible to get optimized views in both domains at once.

Spectrum View is different. It lets you independently adjust time and frequency-domain views, by using patented technology behind each FlexChannel input. You can turn on a spectrum view for any analog channel, enabling multi-channel mixed domain analysis.

Intuitive spectrum analyzer controls like center frequency, span and resolution bandwidth (RBW) make setups easy, and RF vs time triggers make capturing anomalies straightforward.

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

Built-in Spectrum Analyzer

The Tektronix 3 Series MDO offers an integrated, hardware-based spectrum analyzer ranging from 9 kHz to 1 GHz (standard) or 3 GHz enabling spectral analysis on IoT and most consumer wireless standards.

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS
The Spectrogram display illustrates slowly moving RF phenomena. As the peaks change in both frequency and amplitude the changes are easy to see.

Built-in Arbitrary/Function Generator (AFG)

An integrated function generator is perfect for testing frequency response, simulating sensor signals, and adding noise to signals for stress testing.

  • 13 standard waveform functions
  • 50 MHz Sine / 25 MHz Square and Pulse (100 MHz Sine / 50 MHz Square and Pulse on 5 Series B MSO)
  • 128k, 250 MS/s arbitrary waveforms
2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

Connectivity

Every instrument includes a USB device port and LXI-compliant Ethernet port for remote control. A thoroughly documented programming interface supports custom programming.

With e*Scope built-in, you can control the oscilloscope over a network using only a standard web browser.

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

Optional Windows OS

The 5 and 6 Series MSOs offer the option of including a Microsoft Windows™ operating system. The option provides a Windows desktop where you can install and run additional applications on the oscilloscope.

Upgrading to Windows is as simple as plugging in a pre-configured SSD.

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

Applications and Advanced Analysis.Emphasis on Analysis.

Built-in features, available probes, and optional analysis packages support a wide range of applications.

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS
Serial protocol trigger / analysis (optional). Support is available for most common serial bus standards.
2001 SPECIFIED CALIBRATION INTERVALS
Power analysis packages enable automatic measurement of harmonics, switching loss and other key parameters.
2001 SPECIFIED CALIBRATION INTERVALS
EMI Troubleshooting. Spectrum analysis tools help find sources of unwanted emissions.
2001 SPECIFIED CALIBRATION INTERVALS
Power Integrity. Power rail probes and high channel count assist with power rail validation.
2001 SPECIFIED CALIBRATION INTERVALS
Debug motor drive designs by viewing the drive input/output voltage and current signals with waveforms and phasor diagrams.

SignalVu-PC Vector Signal Analysis

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

SignalVu-PC turns your Windows-equipped 5 or 6 Series MSO into a wideband vector signal analyzer. It can be customized to suit your appplication.

  • Perform multi-channel RF measurements
  • Demodulate and analyze RF signals
  • Validate radar or pulsed RF
  • Measure 5G NR signals

Advanced Analysis

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS
Basic jitter measurements are standard. Additional measurements and decomposition come with the Advanced Jitter option.
2001 SPECIFIED CALIBRATION INTERVALS
Automatic compliance test and debugging for popular serial standards.

Software

TekScope PC Analysis Software

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

TekScope emulates the operation of a 4, 5 or 6 Series on your PC.The starter license enables you to view and analyze waveforms, make measurements, remotely access your oscilloscope, and decode I2C, SPI and RS-232.

Advanced licenses add:

  • Multi-scope waveform processing (4/5/6 Series)
  • Serial bus decoding
  • Power analysis
  • Automotive Measurements
  • Aerospace Measurements

TekDrive

2001 SPECIFIED CALIBRATION INTERVALS
2001 SPECIFIED CALIBRATION INTERVALS

An oscilloscope-to-cloud software solution that facilitates data management and collaboration across oscilloscopes, PCs, smart phones, and tablets. On 4, 5 and 6 Series MSOs, TekDrive is accessible right from the Save/Recall controls. TekDrive also includes a well-documented API that enables integration with any software application for automation or analysis.

Probes

IsoVu™ Isolated Probes

IsoVu™ optical isolation technology virtually eliminates common mode interference for accurate differential measurements even with reference voltages slewing ±60 kV at 100 V/ns. Perfect for highside VGS measurements on GaN and SiC power converters.

2001 SPECIFIED CALIBRATION INTERVALS
TIVP Series Specifications
Bandwidth 200 MHz, 500 MHz, 1 GHz
Differential Voltage ±2500 V
Common Mode Voltage ±60 kV
Common Mode Rejection 100 dB @ 200 MHz
2001 SPECIFIED CALIBRATION INTERVALS

TLP058 Logic Probes

Have the right number of digital channels when you need them.Simply connect a TLP058 logic probe to any FlexChannel input and get 8 digital channels. Connect as many TLP058 probes you want.

2001 SPECIFIED CALIBRATION INTERVALS
TLP058 Specifications
Number Of Input Channels 8 digital
Input Resistance 100 kΩ±1.0%
Input Capacitance 3.0pF
Min. Detectable Pulse Width 1ns
Max. Input Toggle Rate 500 MHz
Cable Length 1.0m
2001 SPECIFIED CALIBRATION INTERVALS

Power Rail Probes

Probes designed especially for making accurate ripple measurements on power rails, with ± 60 V DC offset range, low noise contribution and bandwidth up to 4 GHz.

2001 SPECIFIED CALIBRATION INTERVALS
TPR1000/TPR4000 Specifications
Bandwidth TPR1000: 1 GHz
TPR4000: 4 GHz
Attenuation 1.25X
Input impedance 50 kΩ DC - 10 kHz,
50 Ω AC > 100 kHz
Dynamic range ±1 V
Offset range ±60 V
2001 SPECIFIED CALIBRATION INTERVALS

For complete list of available probes visit tek.com/probes

2001 SPECIFIED CALIBRATION INTERVALS
TPP1000/TPP500B

Passive Probes

Model Bandwidth Attenuation Input Impedance Maximum Voltage
TPP1000 1 GHz 10X 10 MΩ || 3.9 pF 300 Vrms (CAT II)
TPP0500B 500 MHz 10X 10 MΩ || 3.9 pF 300 Vrms (CAT II)
TPP0502 500 GHz 2X 2 MΩ || 12.7 pF 300 Vrms (CAT II)
2001 SPECIFIED CALIBRATION INTERVALS
TAP1500

Active Probes

Model Bandwidth Attenuation Input Impedance Dynamic Range Offset Range Maximum Non-Destruct Voltage
TAP1500 1.5 GHz 10X 1 MΩ || ≤ 1 pF ±8 V ±10 V ±15 V
TAP2500 2.5 GHz 10X 40 kΩ || ≤ 0.8 pF ±4 V ±10 V ±30 V
2001 SPECIFIED CALIBRATION INTERVALS
TDP1500

Differential Probes

Model Bandwidth Rise Time Attenuation Differential Operating Voltage Ground Operating Voltage Input resistance/Input capacitance
TDP0500 500 MHz ≤700ps 5X / 50X ±4.25 V (5X)
±42 V (50X)
±35 V 1MΩ/1pF differential
TDP1000 1 GHz ≤350ps 5X / 50X ±4.25 V (5X)
±42 V (50X)
±35 V 1MΩ/1pF differential
TDP1500 1.5 GHz ≤265ps 1X / 10X ±0.85 V (1X)
±8.5 V (10X)
±7.0 V 200KΩ/1pF differential
TDP3500 3.5 GHz ≤140ps 5X ±2 V + 5 to -4 V 100KΩ/0.3pF differential
TDP4000 4.0 GHz ≤126ps 5X ±2 V + 5 to -4 V 100KΩ/0.3pF differential
2001 SPECIFIED CALIBRATION INTERVALS
TPP0850

High Voltage Probes

Model Bandwidth Max Voltage Attenuation Input Impedance Compensation Range
P6015A 75 MHz 20 kVrms
40 kV peak
1000X 100 MΩ || ≤ 3 pF 7 pF – 49 pF
TPP0850 800 MHz 1000 Vrms (CAT II)
2.5 kV peak
50X 40 MΩ || 1.8 pF Auto compensated by scope
2001 SPECIFIED CALIBRATION INTERVALS
THDP0200

High Voltage Differential Probes

Model Bandwidth Rise Time Attenuation Maximum Differential Voltage Maximum Voltage to Earth Ground Differential Input Capacitance Differential Input Resistance
TMDP0200 200 MHz 1.8 ns 25X / 250X ±750 V 550 Vrms (CAT I) 2 pF 5 MΩ
THDP0200 200 MHz 1.8 ns 50X / 500X ±1500 V 1000 Vrms (CAT II) 2 pF 10 MΩ
THDP0100 100 MHz 3.5 ns 100X / 1000X ±6000 V 2300 Vrms (CAT I) 2.5 pF 40 MΩ
2001 SPECIFIED CALIBRATION INTERVALS
TCP0030A

Current Probes

Model Maximum Current Minimum Current Bandwidth Rise Time
TCP0030A 30 A DC; 30 Arms; 50 A peak 1 mA DC - 120 MHz ≤ 2.92 ns
TCP0020 20 A DC; 20 Arms; 100 A peak 10 mA DC - 50 MHz ≤ 7 ns
TCP0150 150 A DC; 150 Arms; 500 A peak 5 mA DC - 20 MHz ≤ 17.5 ns
2001 SPECIFIED CALIBRATION INTERVALS
TDP7708

High Bandwidth Differential Probes

Model Bandwidth
TDP7704 4 GHz
TDP7706 6 GHz
TDP7708 8 GHz
TDP7710 10 GHz
Tekflex Accessory Attenuation Input Impedance Differential Input Voltage Operating Window Offset Range
P77STFLXA,P77STLFXB,P77STCABL 4X 100 kΩ || 0.4 pF 5V ±5.25 V ±4 V
P77BRWSR 10X 150 kΩ || 22 pF 12V ±10 V ±10 V
P77C292MM Variable 50 Ω (SMA) 2V ±4 V ±4 V

Models and Instrument Options

For complete ordering details see the product datasheet or contact your local sales representative.

Base Models 3 Series MDO 4 Series B MSO 5 Series B MSO 6 Series B MSO
Instrument Options 2 TekVPI Channels MDO32
4 TekVPI Channels MDO34
4 FlexChannel Inputs MSO44B MSO54B MSO64B
6 FlexChannel Inputs MSO46B MSO56B MSO66B
8 FlexChannel Inputs MSO58B MSO68B
Bandwidth 100 MHz, 200 MHz, 350 MHz, 500 MHz, 1 GHz 200 MHz, 350 MHz, 500 MHz,1 GHz, 1.5 GHz 350 MHz, 500 MHz, 1 GHz, 2 GHz 1 GHz, 2.5 GHz, 4 GHz, 6 GHz, 8 GHz, 10 GHz
Digital Channels simply order TLP058 probes to enable 8 digital signals per probe
Arbitrary Function Generator
Spectrum Analyzer 1 GHz (std.), 3 GHz see Spectrum View analysis
Extend Record Length (10 M standard) 62.5 M/ch max
(31.25 M standard)
125 M/ch max
250 M/ch max
500 M/ch max
(62.5 M standard)
125 M/ch max
250 M/ch max
500 M/ch max
1 G/ch max
(up to 4 ch)
(62.5 M standard)
Service Options 3 Series MDO 4 Series B MSO 5 Series B MSO 6 Series B MSO
Service Options Warranty Extensions 5 years 3 and 5 years 3 and 5 years 3 and 5 years
Total Product Protection – accident protection, EOS/ESD protection, warranty extension 3 and 5 years 3 and 5 years 3 and 5 years 3 and 5 years
Factory Calibration Plans 3 and 5 years 3 and 5 years 3 and 5 years 3 and 5 years

Learn how to protect your instrument and your uptime with service plans for individual instruments or probes at www.tek.com/factory-service-plans.

For fast, expert calibration services on all your electronic test and measurement equipment (any brand), visit www.tek.com/calibration-services.

Application Software Bundles

Application Software Bundles combine multiple measurement and analysis options for much less than the cost of individual options. They can be a great value, especially if you have a diverse workload.

2001 SPECIFIED CALIBRATION INTERVALS

Find out more in Solution Bundles for 4, 5 and 6 Series MSOs

Individual software options are listed on the next page

2001 SPECIFIED CALIBRATION INTERVALS

Serial Bus Decoding, Compliance/Conformance Testing and Advanced Analysis

Listing of individual software options

Options 3 Series MDO 4 Series B MSO 5 Series B MSO 6 Series B MSO
Serial Decode Options 1-Wire serial decoding and analysis
8b10b serial decoding and analysis
Aerospace serial trig. and analysis
(MIL-STD-1553, ARINC429)
Audio serial trig. and analysis (I2S, LJ, RJ, TDM)
Automotive serial trig. and analysis
(CAN, CAN FD, LIN, FlexRay)
Automotive sensor serial triggering and analysis (SENT)
Computer serial triggering and analysis
(RS-232/422/485/UART)
CXPI serial decoding and analysis
Embedded serial triggering and analysis (I2C, SPI)
EtherCAT serial decoding and analysis
Ethernet serial triggering and analysis
(10BASE-T, 100BASE-TX)
eSPI serial decoding and analysis
eUSB2 serial decoding and analysis
I3C serial decoding and analysis
Manchester triggering and analysis
MDIO serial decoding and analysis
MIPI D-PHY (CSI/DSI) decoding and analysis
NFC (ISO/IEC 15693, 14443A, 14443B, and FeliCa)
NRZ serial decoding and analysis
Power management serial triggering and analysis (SPMI)
PSI5 serial decoding and analysis
SDLC serial decoding and analysis
SMBus serial decoding and analysis
SpaceWire serial decoding and analysis
SVID serial decoding and analysis
USB serial triggering and analysis (USB 2.0 LS, FS, HS)
Compliance Options Automotive Ethernet (10BASE-T1S) compliance solution
Automotive Ethernet (100BASE-T1, 1000BASE-T1, 10BASE-T1S)
automated compliance test application
DDR3 and LPDDR3 automated compliance solution
Ethernet (2.5G and 5G BASE-T) automated compliance solution
Ethernet (10G BASE-T) automated compliance solution
Ethernet (1000BASE-T, 100BASE-T, 10BASE-T, 10Base-T1L) automated compliance solution
MIPI D-PHY 1.2 automated compliance solution
MIPI C-PHY 2.0 automated compliance solution
MIPI D-PHY 2.1 automated compliance solution
Multi-Gigabit Automotive Ethernet (2.5G/5GBASE-T1) automated compliance solution
USB2.0 automated compliance test solution
Analysis Options 3-phase, inverter, motor, drive analysis
3-phase power measurements and analysis
Advanced jitter and eye analysis
Advanced power measurement and analysis
Basic power measurements and analysis
DDR3 and LPDDR3 analysis and debug
DQ0 measurements for inverter motor drives
Enhanced security for instrument declassification
Mechanical measurements for inverter motor drives
Removable SSD with Windows license
RF vs Time traces, triggers, spectrograms and IQ capture
User-defined filter creation tool
Vector signal analysis (SignalVu-PC)

High Speed Digitizers

These low profile digitizers are essentially full-featured 5 and 6 Series oscilloscopes in a compact 2U "rack ready" form factor. They offer the same graphical user interface and performance but in a much smaller package.

2001 SPECIFIED CALIBRATION INTERVALS

5 Series B MSO Low Profile

The 5 Series B MSO is available in a 2U low-profile form factor.Eight channels and 12-bit ADCs set a new standard when extreme channel density and measurement performance are required.

  • 1 GHz bandwidth
  • 6.25 GS/s sample rate
  • 8 FlexChannel inputs
  • Record length from 125 M to 500 M
2001 SPECIFIED CALIBRATION INTERVALS

6 Series Low Profile Digitizer

The 6 Series Low Profile Digitizer sets a new standard for performance by not interleaving sample rate, bandwidth or record length. You get the fastest and most accurate performance from your digitizer – all in a 2U space.

  • 1 GHz to 8 GHz bandwidth
  • 25 GS/s sample rate
  • 4 inputs
  • Record length from 125 M to 1 G

Find more valuable resources at TEK.COM


Copyright © Tektronix. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies.

1/2024 48W-61573-5