Clarius Compliance DDR5 DRAM Receiver Test Solution
Datasheet
The DDR (Dual Data Rate) is a dominant and fast-growing memory technology. It offers high data transfer rates required for virtual computing applications, from consumer products to the most powerful servers. The high speed of these signals requires high-performance measurement tools. The Tektronix Clarius compliance DDR5 DRAM Receiver solution is an automated test application used to validate and debug the DDR5 designs of the DUT (Device Under Test) as per the JEDEC specifications. The solution enables you to achieve new levels of productivity, efficiency, and measurement reliability.
The Clarius compliance is a new-generation compliance test automation software platform that offers a range of features and benefits as follows:
- High asset utilization and faster test times - Disaggregated architecture to offload analysis from the oscilloscope.
- Easy workflow integration – Leverage REST API’s and SDK for faster automation.
- Unified user interface for all technology standards across Transmitter and Receiver.
- Integrated data management for results, reports, and waveforms in UI along with dashboard view.
Key features
- Supports measurements of DDR5 DRAM receiver tests as per JEDEC specifications:
- DQ Voltage Sensitivity Test
- DQS Volage Sensitivity Test
- DQS Jitter Sensitivity Test
- DQ Rx Stressed Eye Test
- Streamline test setup and remotely manage all instruments for simplified operation.
- Leverage pre-built loopback scripts, edit, or even use your own for specific DUT (Device Under Test) setups.
- Automate DUT configuration, calibration, and testing for increased efficiency.
- Adaptive DFE optimization during the calibration.
- Supports de-embedding for all measurements.
- Automated calibration/test of multiple data rates in a single run.
- Perform calibrations using Astek's PTF fixture and replica channel cards for flexible calibration and test setups.
- Simulate real-world channel impairments using external ISI channels for ultimate reliability.
- Gain immediate insights with clear, concise results – no BERT or DDR5 expertise is required.
- Perform comprehensive sweeps, generate bathtub plots, and analyze margins for in-depth optimization.
- Automate complex testing routines and recall them for consistent, time-saving execution.
- Supports single rank and dual rank devices.
- Enhanced debug capability for DUT initialization, Skip Loopback and pause before Phase change.
- BERT offset calibration for VRef DQ settings.
- Offset calculation methods support both the average offset across all phases and individual phase offset calculations.
Effortless test setup
Simplified measurement setup
- User-friendly configuration options streamline the setup process for all receiver measurements.
- Remote instrument control: Remotely control all test instruments including Anritsu’s MP1900A BERT, Astek’s fixtures for simplified operation.
- Automated DUT (Device Under Test) management: The Clarius DDR5 DRAM Rx compliance software automatically programs your DUT into the appropriate loopback mode for each test by saving your valuable time.
Customizable loopback scripts
- Pre-built script library: Leverage our library of pre-configured loopback scripts to quickly match common DUT configurations. Save time and effort by starting with a tested foundation.
- Effortless customization: Easily modify these pre-built scripts to perfectly align with your specific DUT requirements.
- Ultimate control: For highly specialized DUTs, take full control by loading and running your custom loopback scripts within the Clarius DDR5 DRAM Rx compliance framework.
Seamless calibrations
The Clarius DDR5 DRAM Rx compliance solution streamlines the calibration process, ensuring efficient and accurate testing. Automated calibration procedures guide you through the setup for both Astek's PTF fixture and replica channel cards.
Calibration results are conveniently stored within the software, readily accessible for current and future DDR5 receiver DUT testing.
DDR5 DRAM RX Tests
The Clarius DDR5 DRAM Rx solution streamlines the compliance testing process for DDR5 systems and devices, empowering user to achieve faster time-to-market with several innovative features.
Experience a user-friendly, step-by-step interface that accelerates test setup. Effortlessly configure key settings such as data rate, calibration, and test in a single intuitive global configuration window.
The interface groups tests logically by category like DQS Voltage sensitivity, DQ voltage sensitivity, DQS Jitter sensitivity and Stressed eye test and allows for individual test selection.
DUT (Device Under Test) Initialization: This option allows the user to enable/disable the Skip DUT Initialization. When enabled, it Pauses test execution for the user to manually initialize the DUT and continues with Loopback and tests.
Skip Loopback: This option allows the user to enable/disable the Skip Loopback. When enabled, it Pauses test execution for the user to manually put DUT into Loopback and continues with tests.
Pause Before Phase Change: This option allows the user to enable/disable the Pause Before Phase Change. When enabled, it Pauses test execution before running each phase.
Embed and De-embed filters
The Clarius DDR5 DRAM Rx compliance solution simplifies de-embedding filter management, allowing you to incorporate filter files (created by Tektronix's SDLA software) to account for PCB trace, package model, cable, and a portion of the PTF trace. This ensures the most accurate characterization of your DDR receivers, delivering reliable results for confident decision-making.
Specifications
Results and Report
The Clarius DDR5 DRAM Rx compliance solution simplifies result analysis, saving your valuable time and effort.
Automated configuration: The software automatically applies the correct measurement configurations and JEDEC pass/fail limits based on your chosen memory specification and speed grade.
Clear & Concise results: Gain immediate insights with easy-to-understand measurement results; no specialized BERT or DDR5 expertise is required.
Actionable insights at a glance: Quickly visualize performance through comprehensive graphical reports, including bathtub and sweep curves.
Detailed documentation: Generate in-depth reports with all plots, data tables, and relevant information for clear documentation and analysis.
Advanced analysis and margin optimization
The Clarius DDR5 DRAM Rx compliance solution empowers you to go beyond basic compliance testing and unearth valuable insights for optimizing your designs.
Advanced analysis: Leverage our advanced mode for comprehensive parameter sweeps on all measurements, including stressed eye testing. Generate insightful bathtub plots to pinpoint issues and identify areas for margin improvements.
Seamless switching: Effortlessly switch between compliance and advanced modes within the same application, allowing you to efficiently perform standard testing and in-depth analysis as needed.
Real-world margin analysis: Take your testing a step further by incorporating external ISI channels. This simulates real-world channel impairments, providing a more accurate assessment of receiver margins for ultimate reliability.
Import sequence
Save time and effort by creating reusable sequences that automate complex testing routines. Run receiver calibration and tests at various data rates, all in one go. Simply recall the sequence whenever needed, streamlining your testing process, and ensuring consistency.
Ordering information
Hardware requirements
Item | Description | Quantity | Type | Vendor | Requirement |
---|---|---|---|---|---|
DPO72304DX or MSO72304DX or DPO72304SX | Real Time Oscilloscope with Bandwidth ≥ 23 GHz, Windows 10 OS | 1 | Equipment | Tektronix | Required |
Bit Error Rate Tester (BERT) | MP1900A | 1 | Equipment | Anritsu | Required |
3 Channel Programmable Power Supply for powering fixtures | 2230-30-3 | 1 | Equipment | Keithley | Required |
Host PC or Laptop | Refer to system requirements for configuration | - | PC or Laptop | - | Required |
USB Vector Network Analyzer, 1 MHz - 8 GHz | MS46122B | 1 | Equipment | Anritsu | Recommended |
Test fixtures and accessories
Item | Description | Quantity | Type | Vendor | Requirement |
---|---|---|---|---|---|
CTC2 Test Fixture | A9-CTC2-01 | 1 | Fixture | Astek | Required |
Parametric Test Fixture (PTF) for calibration | A9-DIMM5-01 | 1 | Fixture | Astek | Required |
Astek Reset Automation Kit | A9-AUTO-01 | 1 | Fixture | Astek | Required |
DDR5 Replica Channel Card | A9-RPLC-01 | 1 | Fixture | Astek | Required |
SMA-SMA, 1-meter, phase matched cable pair | PMCABLE1M | 4 | Accessory | Tektronix | Required |
SMA-SMP adaptor, right angle (pair) | 174-6657-01 | 4 | Accessory | Tektronix | Required |
ISI board | J1800A/J1758A | 1 | Fixture | Anritsu | Optional |
Precision Fixed Attenuator, 41 Series, DC to 26.5 GHz, 6 dB attenuation | 41KC-6 | 3 | Accessory | Antirsu | Required |
Software requirements
Item | Description | Quantity | Type | Vendor | Requirement |
---|---|---|---|---|---|
Clarius compliance DDR5 DRAM Rx software. Refer to License options. | DDR5 DRAM RX | 1 | Option | Tektronix | Required |
Item | Description | Quantity | Type | Vendor | Requirement |
---|---|---|---|---|---|
Serial Data Link Analysis for Windows 64-bit oscilloscopes. | SDLA64 | 1 | Option | Tektronix | Required |
DPOJET Jitter Analysis. | DJA | 1 | Option | Tektronix | Required |
System requirements
The following table shows the minimum system requirements to install and run the Clarius compliance DDR5 Rx.
Pre-requisites | Recommended requirements |
---|---|
Operating system |
Language: English (United States) only. |
CPU cores | 16 |
RAM | 64 GB |
Disk space | 300 GB HDD/SSD of free disk space |
Internet speed | ≥ 50 Mbps |
Browser | Google Chrome or Microsoft Edge |
Additional software |
|
License options
Clarius DDR5 DRAM Rx software options
License terms | License option | Description |
---|---|---|
Subscription | AT-DDR5-Rx-NS1 | Clarius DDR5 Rx Automation; Node-locked, Subscription, 1 Year |
AT- DDR5-Rx-NS3 | Clarius DDR5 Rx Automation; Node-locked, Subscription, 3 Years | |
AT- DDR5-Rx-FS1 | Clarius DDR5 Rx Automation; Floating, Subscription, 1 Year | |
AT- DDR5-Rx-FS3 | Clarius DDR5 Rx Automation; Floating, Subscription, 3 Years |