TDP7000 Series TriMode Probes Datasheet
Дополнительные сведения
- Низковольтные дифференциальные пробники
- Поддержка приборов
- Explore more Software models
Читать на веб-сайте:
The TDP7700 Series TriMode probes provide the highest probe fidelity available for real-time oscilloscopes. In addition, with connectivity innovations such as solder down tips with the probe’s input buffer mounted only a few millimeters from the end of the tip, the TDP7700 series probes provide unmatched usability for connecting to today’s most challenging electronic designs.
Key features
- High bandwidth for signal fidelity
- 10 GHz TDP7710
- 8 GHz TDP7708
- 6 GHz TDP7706
- 4 GHz TDP7704
- Minimal device impact
- Thin and flexible solder tips
- Lightweight and flexible probe cable
- Active buffer tip design for low probe loading
- Easy to connect TekFlex™ Connector technology
- Pinch-to-Open accessory connector
- Versatile Connectivity - solder-down tips, optional browser for handheld or fixtured probing, and coaxial input (SMA adapter)
- Cross compatibility with P7700 series tip accessories
- Full Bandwidth to 10 GHz
- Probe cable and solder-down tips operate over an extended temperature range
- Probe and tip specific S-parameters
- Full AC calibration of the probe and tip's signal path based upon unique s-parameter models
- Unique DSP filters created for each probe and tip
- FlexChannel® interface for oscilloscope/probe control and usability
- Direct control via probe buttons or from the oscilloscope's menus
- Automated control of probe settings via the oscilloscope
- Automatic recognition of the probe and tip when attached to the oscilloscope
TDP7700 Series TriMode Probes
With TriMode probing one probe setup makes differential, single ended, and common mode measurements accurately. This unique capability allows you to work more effectively and efficiently, switching between differential, single ended and common mode measurements without moving the probe's connection points.
TekFlex connector technology
The TDP7700 Series TriMode probes use the new TekFlex connector technology that combines a high speed signal path with power and communication support for an active buffer tip in a single, easy to connect accessory connector. The TekFlex connector has a pinch-to-open design that when open requires minimal force to attach an accessory tip. When the TekFlex connector is closed, it provides a secure connection to the accessory to avoid accidental disconnections.
With the TekFlex connector, the TDP7700 series probes offer a set of active probe tips with the probe's buffer amplifier only millimeters from the input connections. The short signal path enabled with the active tips provides high fidelity and a high impedance input. It also minimizes signal loss, capacitance, and additive noise.
Browser accessory for handheld probing
When you need to make a quick measurement or debug a problem, the TDP7700 series browser accessory provides a simple to use option. With precision engineered tips that are easy to see and position accurately, the P77BRWSR handheld browser accessory enables hand or fixtured probing and is ideal for probing fine pitch components and differential traces with spacing as narrow as 0.2 mm (.008 in).
The browser's tips have a full range of compliance and are adjustable in spacing using a convenient thumb wheel. A headlight on the tip enhances visibility of the probe point and can be switched on and off as needed. The browser tips are constructed of high strength BeCu and super-ceramic resistors (patent pending pin technology). TheP77BRWSR handheld browser accessory enables hand or fixtured probing with signal fidelity and convenience.
Coaxial input (SMA) adapter
RF/coaxial connectors, such as SMA, are often found on test fixtures or on prototype board designs. Attaching a TDP7700 series probe to these on-board connectors is easy with the SMA adapter. The P77C292MM adapter allows you to connect to 2.92 mm, 3.5 mm or SMA connectors with full bandwidth and low noise. The P77C292MM adapter includes TriMode functionality enabling differential, single ended, and common mode measurements.
The termination voltage can be set manually or automatically using voltage sense circuitry in the TDP7700 probe and covers a range of ±2.5 V.
Specifications
Specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.
Model overview
Characteristic | Description |
---|---|
Bandwidth (typical) | TDP7704: 4 GHz |
TDP7706: 6 GHz | |
TDP7708: 8 GHz | |
TDP7710: 10 GHz | |
Operating Voltage Window, A and B inputs | ±4 V (2.92 tip) |
±5.25 V (active tip) | |
±10 V (browser tip) | |
Differential Input Range | ±2V (2.92 tip) |
±5V (active tip) | |
±12V (browser tip) | |
DC input resistance (differential) | 50 Ω (P77C292MM tip) |
100k Ω (active tips) | |
144k Ω (browser tip) | |
DC Accuracy | ±2% |
TriMode functionality | Yes; Differential only (browser tip) |
Electrical characteristics
- Attenuation
- Solder-in tips
- 4x
- Browser
- 10x
- Coaxial input (SMA) adapter
- 0.7x/1.3x/2.7x/5x/10x
- DC gain accuracy, typical
- ±2.0%
- Output zero, typical
- ±4 mV
- Linearity, typical
- ±1%
- Input sense voltage accuracy, typical
- Vin ±30 mV over the operating voltage range of the 2.92 mm adapter tip.
- Termination voltage range, typical
- ± 2.5 mV.
- Overload indicator range, typical
- The Overload indicator is active when the probe input is current limited or when an input overvoltage condition is detected.
- CMRR/DMRR, typical
Frequency range Min. CMRR/DMRR ≤ 50 MHz 34 dB > 50 MHz, ≤ 800 MHz 24 dB > 800 MHz, ≤ 4 GHz 14 dB > 4 GHz, ≤ 10 GHz 10 dB - Time delay, typical
5.05 ns ± 0.1 ns
- Small signal rise time, typical
Probe 10% - 90% Rise time 20% - 80% Rise Time TDP7710 <45 ps <32 ps TDP7708 <55 ps <38 ps TDP7706 <65 ps <46 ps TDP7704 <100 ps <72 ps - Small signal frequency response, typical
Probe Frequency response TDP7710 ≥10 GHz TDP7708 ≥8 GHz TDP7706 ≥6 GHz TDP7704 ≥4 GHz - System noise, 10 mvV/div, probe with P77STCABL tip
- System Noise
Probe A, B mode C mode D mode TDP7710 <4.65 mV RMS <4.65 mV RMS <4.65 mV RMS TDP7708 <4.65 mV RMS <4.65 mV RMS <4.65 mV RMS TDP7706 <4.1 mV RMS <4.1 mV RMS <4.1 mV RMS TDP7704 <4.1 mV RMS <4.1 mV RMS <4.1 mV RMS - System Noise, typical
Probe A, B mode C mode D mode TDP7710 <3.6 mV RMS <2.8 mV RMS <3.9 mV RMS TDP7708 <3.3 mV RMS <2.6 mV RMS <3.8 mV RMS TDP7706 <3.0 mV RMS <2.5 mV RMS <3.7 mV RMS TDP7704 <2.7 mV RMS < 2.3 mV RMS <3.2 mV RMS
- DC input resistance, typical
Tips/Adapters Differential P77C292MM 100 Ω
P77STFLXA, P77STCABL 100 kΩ
P77BRWSR 144 kΩ ± 20%
- Low frequency input capacitance (differential, typical)
- Solder-in tips
- 0.4 pF
- Browser
- 0.23 pF @ 50 mil spacing
- 0.22 pF @ 200 mil spacing
- Operating voltage window, typical
- Solder-in tips
- ±5.25 V
- Browser
- ±10 V
- SMA adapter
- ±4 V
- DC gain accuracy, typical
- ±2.0%
- Offset voltage range, typical
- Solder-in tips
- -4 V to +4 V
- Browser
- -10 V to +10 V
- SMA adapter
- -4 V to +4 V
- Non-destructive input range, typical
- Solder-in tips, Browser
- -15 V to +15 V
- SMA adapter
- -5 V to +5 V
- Input slew rate, typical
- ≥ 30 V/ns, single-ended, both inputs
- Input range, typical
- Solder-in tips
Single-ended Differential 2.5 Vpp 5.0 Vpp - Browser
Single-ended Differential 6.0 Vpp 12.0 Vpp - SMA adapter
Single-ended Differential 1.2 Vpp 2.0 Vpp
- SMA adapter termination voltage range
- -4 V to +4 V
Impedance graphs
Nominal characteristics
- Weight
- Probe cable and head
- 3.5 oz
- Probe (comp box, cable, head)
- 9.6 oz
- Cable length
- 1.21 m (4.0 feet)
- Oscilloscope interface
- TekVPI ®
- Accessory connector
- TekFlex
Environmental
- Operating
Item Specification Compensation box and browser 0 °C to +50 °C (32 °F to 122 °F) Cable and solder-in tips -35 °C to 85 °C (-31 °F to 185 °F) SMA adapter -35 °C to 85 °C (-31 °F to 185 °F) - Non-operating
Item Specification Compensation box and browser -20 °C to +60 °C (-4 °F to 140 °F) P77C292MM (SMA adapter) -35 °C to 85 °C (-31 °F to 185 °F) Cable and Solder-in Tips -35 °C to 85 °C (-31 °F to 185 °F) - Altitude non-operating
- 12,000 meters
- Humidity, comp box
- Operating
- 5% to 90% relative humidity (% RH) at up to +40 °C, 5% to 55% RH above +40 °C up to +50 °C, non-condensing.
- Nonoperating
- 5% to 90% RH (Relative Humidity) at up to +40 °C, 5% to 55% RH above +40 °C up to +60 °C, non-condensing.
Compatibility
- Compatible oscilloscopes
- The TDP7700 series probes are compatible with the following oscilloscopes: MSO6 series
Ordering information
- TDP7710
- 10 GHz TriMode probe with TekFlex connector technology
- TDP7708
- 8 GHz TriMode probe with TekFlex connector technology
- TDP7706
- 6 GHz TriMode probe with TekFlex connector technology
- TDP7704
- 4 GHz TriMode probe with TekFlex connector technology
Standard accessories
All probes include the following items: Manual, Two solder-in tips, Certificate of traceable calibration, Calibration data report, One-year warranty.
Below is the list of standard accessories:
Service options
- Opt. C3
- Calibration Service 3 Years
- Opt. C5
- Calibration Service 5 Years
- Opt. D3
- Calibration Data Report 3 Years (with Opt. C3)
- Opt. D5
- Calibration Data Report 5 Years (with Opt. C5)
- Opt. G3
- Complete Care 3 Years (includes loaner, scheduled calibration, and more)
- Opt. G5
- Complete Care 5 Years (includes loaner, scheduled calibration, and more)
- Opt. R3
- Repair Service 3 Years (including warranty)
- Opt. R3DW
Repair Service Coverage 3 Years (includes product warranty period). 3-year period starts at time of instrument purchase
- Opt. R5
- Repair Service 5 Years (including warranty)
- Opt. R5DW
Repair Service Coverage 5 Years (includes product warranty period). 5-year period starts at time of instrument purchase
Recommended accessories
- P77STFLXA
- Active, solder-in tip with TekFlex connector technology, 20 GHz (5 tips/kit). Each probe ships with two of these solder-in tips as standard accessories.
- P77STFLXB
- Active, 75 Ω solder-in tip with TekFlex connector technology for DDR4/LPDDR4 electrical validation, 15 GHz (5 tips/kit). For use with Nexus Technology XH Series Interposers.
- P77STCABL
- Active, coaxial cable based, solder-in tip with TekFlex connector technology, 20 GHz
- P77BRWSR
- Browser accessory with TekFlex connector technology, 16 GHz
- P77C292MM
- SMA Coaxial adapter with TekFlex connector technology, 20 GHz
- 407-6019-xx
- Probe adapter to attach the browser to the PPM203B articulated arm/positioner
Replacement parts
Tektronix part number | Description | |
---|---|---|
P77STFLXA | Active, solder-in tip with TekFlex connector technology, 20 GHz (5 tips/kit). Each probe ships with two of these solder-in tips as standard accessories. | |
P77STFLXB | Flex circuit based DDR4/LPDDR4 memory solder in tips. These tips use flex circuit material and provide soldered, multi-point connections. They support full TriMode measurement capabilities and full probe bandwidth, 15 GHz (5 tips/kit). | |
P77STCABL | Active, coaxial cable based, solder-in tip with TekFlex connector technology, 20 GHz | |
P77BRWSR | Browser accessory with TekFlex connector technology, 16 GHz | |
P77C292MM | SMA Coaxial adapter with TekFlex connector technology, 20 GHz | |
407-6019-xx | Probe adapter to attach the browser to the PPM203B articulated arm/positioner | |
020-3162-xx | Replacement tip for browser accessory | |
020-3160-xx | Browser pen wand | |
020-3161-xx | Browser hands-free tripod | |
020-3163-xx | Browser adapters | |
121-1003-xx | Magnetic cable holder | |
129-1867-xx | Large metal cable band | |
129-1857-xx | Small metal cable band | |
196-3436-xx | Browser ground lead | |
016-2111-xx | Color bands | |
017-0103-xx | 38 AWG wire spool | |
020-3167-xx | Double-sided adhesive tape |